{"_buckets": {"deposit": "dc78a0c2-1b4a-408e-96d8-b20fed9b45b2"}, "_deposit": {"id": "13467", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "13467"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00013467", "sets": ["1310"]}, "author_link": ["41077", "41078", "41079", "41080"], "item_1628147817048": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_6_alternative_title_1": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Patient-Specific Modeling Based on the X-ray CT Images (New Meshing Algorithm Considering Bony Shape and Density)"}]}, "item_6_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "717", "bibliographicPageEnd": "1477", "bibliographicPageStart": "1470", "bibliographicVolumeNumber": "72", "bibliographic_titles": [{"bibliographic_title": "日本機械学会論文集. C編"}]}]}, "item_6_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This study deals with a patient-specific modeling method that generates a finite element model based on the X-ray CT images. The basic idea of our modeling method is to express an objective shape with small tetrahedral elements. This paper proposes a new meshing algorithm that controls element size according to shape or density information extracted from the CT images. For the automated modeling, we introduce \"from factor\" that indicates degree of complexity of the objective shape. The factor at a remarking point is easily obtained by a simple calculation using a local inspection region around the point. The new method produces a finite element model with variable mesh size. To validate the method, we discuss following three issues: proper volume of the inspection region for precise modeling, accuracy verification of stress analysis, and required working time for modeling and analysis. The computational results by the proposed method shows good analytical precision with a smaller FE model.", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_31": {"attribute_name": "フォーマット:mimeタイプ", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "日本機械学会論文集. C編. 72(717):1470-1477 (2006)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "信州大学研究者総覧へのリンク", "attribute_value_mlt": [{"subitem_link_text": "小関, 道彦", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.ZenFupLV.html"}]}, "item_6_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "社団法人日本機械学会"}]}, "item_6_relation_51": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110004738281/", "subitem_relation_type_select": "URI"}}]}, "item_6_rights_62": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright (c) 2006 社団法人 日本機械学会"}, {"subitem_rights": "本文データは学協会の許諾に基づきCiNiiから複製したものである"}]}, "item_6_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0387-5024", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0387-5024", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00187463", "subitem_source_identifier_type": "NCID"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "小関, 道彦"}], "nameIdentifiers": [{"nameIdentifier": "41077", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上西, 雅也"}], "nameIdentifiers": [{"nameIdentifier": "41078", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "伊能, 教夫"}], "nameIdentifiers": [{"nameIdentifier": "41079", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "槇, 宏太郎"}], "nameIdentifiers": [{"nameIdentifier": "41080", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "110004738281.pdf", "filesize": [{"value": "1.3 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 1300000.0, "url": {"label": "110004738281.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/13467/files/110004738281.pdf"}, "version_id": "4337adb6-80fa-4bc8-bbbc-98f3b76c6968"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Biomechanics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Computational Mechanics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Finite Element Method", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Patient-Specific Model", "subitem_subject_scheme": "Other"}, {"subitem_subject": "X-ray CT", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Mandible", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Skull", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "X線CT画像に基づく骨体の個体別モデリング手法に関する研究(骨形態を考慮した要素分割手法の提案)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "X線CT画像に基づく骨体の個体別モデリング手法に関する研究(骨形態を考慮した要素分割手法の提案)", "subitem_title_language": "ja"}]}, "item_type_id": "6", "owner": "1", "path": ["1310"], "permalink_uri": "http://hdl.handle.net/10091/3822", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2010-01-21"}, "publish_date": "2010-01-21", "publish_status": "0", "recid": "13467", "relation": {}, "relation_version_is_last": true, "title": ["X線CT画像に基づく骨体の個体別モデリング手法に関する研究(骨形態を考慮した要素分割手法の提案)"], "weko_shared_id": -1}
X線CT画像に基づく骨体の個体別モデリング手法に関する研究(骨形態を考慮した要素分割手法の提案)
http://hdl.handle.net/10091/3822
http://hdl.handle.net/10091/38220e610dd6-c305-4166-b9c5-eea5b9ba68ff
名前 / ファイル | ライセンス | アクション |
---|---|---|
110004738281.pdf (1.3 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-01-21 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | X線CT画像に基づく骨体の個体別モデリング手法に関する研究(骨形態を考慮した要素分割手法の提案) | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題 | Biomechanics, Computational Mechanics, Finite Element Method, Patient-Specific Model, X-ray CT, Mandible, Skull | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | Patient-Specific Modeling Based on the X-ray CT Images (New Meshing Algorithm Considering Bony Shape and Density) | |||||
著者 |
小関, 道彦
× 小関, 道彦× 上西, 雅也× 伊能, 教夫× 槇, 宏太郎 |
|||||
信州大学研究者総覧へのリンク | ||||||
氏名 | 小関, 道彦 | |||||
URL | http://soar-rd.shinshu-u.ac.jp/profile/ja.ZenFupLV.html | |||||
出版者 | ||||||
出版者 | 社団法人日本機械学会 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 日本機械学会論文集. C編. 72(717):1470-1477 (2006) | |||||
書誌情報 |
日本機械学会論文集. C編 巻 72, 号 717, p. 1470-1477, 発行日 2006-05 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This study deals with a patient-specific modeling method that generates a finite element model based on the X-ray CT images. The basic idea of our modeling method is to express an objective shape with small tetrahedral elements. This paper proposes a new meshing algorithm that controls element size according to shape or density information extracted from the CT images. For the automated modeling, we introduce "from factor" that indicates degree of complexity of the objective shape. The factor at a remarking point is easily obtained by a simple calculation using a local inspection region around the point. The new method produces a finite element model with variable mesh size. To validate the method, we discuss following three issues: proper volume of the inspection region for precise modeling, accuracy verification of stress analysis, and required working time for modeling and analysis. The computational results by the proposed method shows good analytical precision with a smaller FE model. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0387-5024 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00187463 | |||||
異版である | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://ci.nii.ac.jp/naid/110004738281/ | |||||
権利 | ||||||
権利情報 | Copyright (c) 2006 社団法人 日本機械学会 | |||||
権利 | ||||||
権利情報 | 本文データは学協会の許諾に基づきCiNiiから複製したものである | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |