WEKO3
アイテム
{"_buckets": {"deposit": "00794ba4-ced8-46e6-b32f-ffff16726778"}, "_deposit": {"id": "6941", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "6941"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00006941", "sets": []}, "author_link": ["16845", "16846", "16847", "16848"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1993-02-28", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "29", "bibliographicPageStart": "19", "bibliographicVolumeNumber": "18", "bibliographic_titles": [{"bibliographic_title": "紀要"}]}]}, "item_10_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The incidence of diabetes mellitus is increasing every year,recently. A blood sugar value is one of the most important items in blood tests, and it varies with meals or exercises. Therefore it is necessary to establish a simple and accurate method for measuring glucose concentration. A glucose sensor is newly invented by applying SOS (Silicone On Sapphire)/ISFET (Ion Sensitive Field Effect Transistor). In this paper, its efficiency in measuring glucose concentration in blood plasma is investigated.", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "フォーマット:mimeタイプ", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "紀要 18: 19-29(1993)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "信州大学医療技術短期大学部"}]}, "item_10_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385-1982", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385-1982", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10402438", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "03"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "兼吉, 昭雄", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "16845", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "篠原, 志緒", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "16846", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田, 安雄", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "16847", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "大倉, 博文", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "16848", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Allied_Med18_03.pdf", "filesize": [{"value": "871.5 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 871500.0, "url": {"label": "Allied_Med18_03.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/6941/files/Allied_Med18_03.pdf"}, "version_id": "3dbd34dd-b5a9-4054-bb2f-2d8f37c47c57"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "バイオセンサ", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "半導体", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "SOS/イオン感応性電界効果トランジスタ", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "血糖値", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "グルコース", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Biosensor", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Semiconductor", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "SOS/ISFET", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "blood sugar", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "glucose", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "半導体グルコースセンサの臨床的評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "半導体グルコースセンサの臨床的評価", "subitem_title_language": "ja"}, {"subitem_title": "Clinical Evaluation of Semiconductor Biosensor", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["815"], "permalink_uri": "http://hdl.handle.net/10091/5165", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2010-03-01"}, "publish_date": "2010-03-01", "publish_status": "0", "recid": "6941", "relation": {}, "relation_version_is_last": true, "title": ["半導体グルコースセンサの臨床的評価"], "weko_shared_id": -1}
半導体グルコースセンサの臨床的評価
http://hdl.handle.net/10091/5165
http://hdl.handle.net/10091/51652396a9df-007d-4acb-9892-4c9be946171d
名前 / ファイル | ライセンス | アクション |
---|---|---|
Allied_Med18_03.pdf (871.5 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-03-01 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 半導体グルコースセンサの臨床的評価 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Clinical Evaluation of Semiconductor Biosensor | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題 | バイオセンサ, 半導体, SOS/イオン感応性電界効果トランジスタ, 血糖値, グルコース Biosensor, Semiconductor, SOS/ISFET, blood sugar, glucose |
|||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
著者 |
兼吉, 昭雄
× 兼吉, 昭雄× 篠原, 志緒× 吉田, 安雄× 大倉, 博文 |
|||||
出版者 | ||||||
出版者 | 信州大学医療技術短期大学部 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 紀要 18: 19-29(1993) | |||||
書誌情報 |
紀要 巻 18, p. 19-29, 発行日 1993-02-28 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The incidence of diabetes mellitus is increasing every year,recently. A blood sugar value is one of the most important items in blood tests, and it varies with meals or exercises. Therefore it is necessary to establish a simple and accurate method for measuring glucose concentration. A glucose sensor is newly invented by applying SOS (Silicone On Sapphire)/ISFET (Ion Sensitive Field Effect Transistor). In this paper, its efficiency in measuring glucose concentration in blood plasma is investigated. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0385-1982 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10402438 |