{"_buckets": {"deposit": "9b601958-ec5c-49b8-838d-bb751eb2723e"}, "_deposit": {"id": "6989", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "6989"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00006989", "sets": []}, "author_link": ["16973", "16974"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1988-03-26", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "63", "bibliographicPageStart": "59", "bibliographicVolumeNumber": "13", "bibliographic_titles": [{"bibliographic_title": "紀要"}]}]}, "item_10_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Thermoplastics are being commonly used for hand splinting in combination with different shock absorbers. In order to assess the effect of splinting on temperature and humidity in the interstice (the space between the shock absorber and the skin), 1 gyps and 6 thermoplastic cock-up splints with a shock absorber for each, were fitted into 10 normal subjects. The thermal and humidity censor was set at two different points in the interstice : the frontal center of the forearm and the center of the palm. the successive change of temperature and humidity per minute was recorded by the micro memorycorder for 3 hours. In relation to the change, of temperature there was not a significant difference among shock absorbers in both points. However, the humidity was the highest in the PE-right (2.8mm) and lowered in the order of the cotton (0.2mm), no shock absorber, the Ortex, the leather (1. 6mm), the gyps, and the felt (3. 0mm). The humidity of the palm was 10-20% higher than the forearm. The results suggest that the shock absorver for hand splinting should be aerate and hydrophilic in quality the texture to decrease the physical uncomfortableness from perspiration.", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "フォーマット:mimeタイプ", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "紀要 13(2): 59-63(1988)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "信州大学医療技術短期大学部"}]}, "item_10_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385-1982", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385-1982", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00354907", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "05"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "清水, 順市", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "16973", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤, 真一", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "16974", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Allied_Med13_2_05.pdf", "filesize": [{"value": "256.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 256600.00000000003, "url": {"label": "Allied_Med13_2_05.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/6989/files/Allied_Med13_2_05.pdf"}, "version_id": "8d93c8b5-ac3e-4e52-81b6-266e988dab4e"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "cock-up split", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "interstice temperature and humidity", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "shock absorbers for splinting", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "装具装着時の装具内における温度・湿度の継時的変化 : 装具,温度,湿度", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "装具装着時の装具内における温度・湿度の継時的変化 : 装具,温度,湿度", "subitem_title_language": "ja"}, {"subitem_title": "A comparison of temperature and humidity in the interstice of cock-up splint with different shock absorbers", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["823"], "permalink_uri": "http://hdl.handle.net/10091/5126", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2010-03-01"}, "publish_date": "2010-03-01", "publish_status": "0", "recid": "6989", "relation": {}, "relation_version_is_last": true, "title": ["装具装着時の装具内における温度・湿度の継時的変化 : 装具,温度,湿度"], "weko_shared_id": -1}
装具装着時の装具内における温度・湿度の継時的変化 : 装具,温度,湿度
http://hdl.handle.net/10091/5126
http://hdl.handle.net/10091/5126e3cef578-13fd-43a1-832c-40c015347472
名前 / ファイル | ライセンス | アクション |
---|---|---|
Allied_Med13_2_05.pdf (256.6 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-03-01 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 装具装着時の装具内における温度・湿度の継時的変化 : 装具,温度,湿度 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | A comparison of temperature and humidity in the interstice of cock-up splint with different shock absorbers | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題 | cock-up split, interstice temperature and humidity, shock absorbers for splinting | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
著者 |
清水, 順市
× 清水, 順市× 佐藤, 真一 |
|||||
出版者 | ||||||
出版者 | 信州大学医療技術短期大学部 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 紀要 13(2): 59-63(1988) | |||||
書誌情報 |
紀要 巻 13, 号 2, p. 59-63, 発行日 1988-03-26 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Thermoplastics are being commonly used for hand splinting in combination with different shock absorbers. In order to assess the effect of splinting on temperature and humidity in the interstice (the space between the shock absorber and the skin), 1 gyps and 6 thermoplastic cock-up splints with a shock absorber for each, were fitted into 10 normal subjects. The thermal and humidity censor was set at two different points in the interstice : the frontal center of the forearm and the center of the palm. the successive change of temperature and humidity per minute was recorded by the micro memorycorder for 3 hours. In relation to the change, of temperature there was not a significant difference among shock absorbers in both points. However, the humidity was the highest in the PE-right (2.8mm) and lowered in the order of the cotton (0.2mm), no shock absorber, the Ortex, the leather (1. 6mm), the gyps, and the felt (3. 0mm). The humidity of the palm was 10-20% higher than the forearm. The results suggest that the shock absorver for hand splinting should be aerate and hydrophilic in quality the texture to decrease the physical uncomfortableness from perspiration. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0385-1982 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00354907 |