{"_buckets": {"deposit": "1b2e3f39-6d3e-497c-b324-c8f36145e6a6"}, "_deposit": {"id": "8421", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "8421"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00008421", "sets": []}, "author_link": ["24187", "24188", "24189", "24190"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "109", "bibliographicPageStart": "104", "bibliographicVolumeNumber": "32", "bibliographic_titles": [{"bibliographic_title": "信州大学医学部附属病院看護研究集録"}]}]}, "item_10_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "人工呼吸器加温加湿器のFisher\u0026Paykel社製のMR730を使用しFisher\u0026Paykel社製R206回路で、人工肺を用い各設定による回路内結露量を測定した。再生回路との結露量の差を調べた。又、回路汚染を調べた。206回路は、再生回路より結露が多く、チャンバー温は+設定にしない事が望ましい。患者の喀痰から検出された菌がチャンバーから検出された。回路汚染の予防には、結露を生じない設定と回路内の水分を排除し、逆流させない事が重要である。", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "信州大学医学部附属病院看護研究集録 32(1): 104-109(2004)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "信州大学医学部附属病院看護部"}]}, "item_10_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1343-3059", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1343-3059", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11387338", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "18"}]}, "item_1627890569677": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "高尾, ゆきえ", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "24187", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "壬生, 菊代", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "24188", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石井, 留美子", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "24189", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小林, 利江", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "24190", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Nurshing_Research31-02-18.pdf", "filesize": [{"value": "1.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 1100000.0, "url": {"label": "Nurshing_Research31-02-18.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/8421/files/Nurshing_Research31-02-18.pdf"}, "version_id": "51776640-209e-4757-9fe9-9783e56dee77"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "人工呼吸器回路", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "加温加湿", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}, {"subitem_subject": "回路汚染", "subitem_subject_language": "ja", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "人工呼吸器回路内結露と汚染について", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "人工呼吸器回路内結露と汚染について", "subitem_title_language": "ja"}, {"subitem_title": "condensation of the ventilator circuit and contaminated circuit", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["896"], "permalink_uri": "http://hdl.handle.net/10091/15085", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2012-03-19"}, "publish_date": "2012-03-19", "publish_status": "0", "recid": "8421", "relation": {}, "relation_version_is_last": true, "title": ["人工呼吸器回路内結露と汚染について"], "weko_shared_id": -1}
人工呼吸器回路内結露と汚染について
http://hdl.handle.net/10091/15085
http://hdl.handle.net/10091/15085e0791361-4cd4-4aa5-b408-8dc2e1fdd088
名前 / ファイル | ライセンス | アクション |
---|---|---|
Nurshing_Research31-02-18.pdf (1.1 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-03-19 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 人工呼吸器回路内結露と汚染について | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | condensation of the ventilator circuit and contaminated circuit | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題 | 人工呼吸器回路, 加温加湿, 回路汚染 | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
著者 |
高尾, ゆきえ
× 高尾, ゆきえ× 壬生, 菊代× 石井, 留美子× 小林, 利江 |
|||||
出版者 | ||||||
出版者 | 信州大学医学部附属病院看護部 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 信州大学医学部附属病院看護研究集録 32(1): 104-109(2004) | |||||
書誌情報 |
信州大学医学部附属病院看護研究集録 巻 32, 号 1, p. 104-109, 発行日 2004-03 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 人工呼吸器加温加湿器のFisher&Paykel社製のMR730を使用しFisher&Paykel社製R206回路で、人工肺を用い各設定による回路内結露量を測定した。再生回路との結露量の差を調べた。又、回路汚染を調べた。206回路は、再生回路より結露が多く、チャンバー温は+設定にしない事が望ましい。患者の喀痰から検出された菌がチャンバーから検出された。回路汚染の予防には、結露を生じない設定と回路内の水分を排除し、逆流させない事が重要である。 | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1343-3059 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11387338 | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |