狭小弁輪を伴う,高齢者大動脈弁狭窄症に対し,生体弁 (Carpentier Edwards Perimount Magna)による弁置換を 施行した1例
An Aortic Replacement with a Bioprosthesis (Carpentier-Edwards Perimount Magna) for Aortic Valve Stenosis with a Small Annulus in an Elderly Patient
月岡, 勝晶
恒元, 秀夫
Perimount Magna aortic valve replacement
small annulus
biological prosthesis
大動脈弁置換術
狭小弁輪
生体弁
An 82-year-old female was admitted to our hospital in December 2006 due to dyspnea resulting from cardiac failure accompanied by severe aortic stenosis and pulmonary hypertension. She recovered after medical treatment, but she was admitted again on May 7, 2008 because of exacerbated dyspnea. Echocardiographic examination revealed aortic stenosis with a peak pressure gradient (PG) of 63 mmHg and severe tricuspidal regurgitation (TR).Cardiac catheterization showed an aortic valve area of 0.52㎠. On June 6,2008 she underwent aortic valve replacement (AVR) and tricuspid annuloplasty according to Kay’s method. Although a sizer for a Carpentier-Edwards standard prosthesis of 19 mm could not be inserted,another for a Carpentier-Edwards Perimount Magna prosthesis of 19 mm was inserted, and AVR was accomplished with this bioprosthesis while avoiding aortic annular enlargement. The patient recovered uneventfully and was discharged on the twelfth-postoperative-day. The results of postoperative echocardiography were ejection fraction 61%, mean PG 14 mmHg and, mild TR.
Article
信州医学雑誌 57(2): 71-74(2009)
journal article
信州医学会
2009-04-10
application/pdf
信州医学雑誌
2
57
71
74
0037-3826
AN00120815
https://soar-ir.repo.nii.ac.jp/record/4195/files/shinshu_Med57-2-03.pdf
jpn
10.11441/shinshumedj.57.71
https://doi.org/10.11441/shinshumedj.57.71