{"created":"2021-03-01T06:14:44.462572+00:00","id":11841,"links":{},"metadata":{"_buckets":{"deposit":"2d73dceb-5c0a-45d6-a037-be810301fd20"},"_deposit":{"id":"11841","owners":[],"pid":{"revision_id":0,"type":"depid","value":"11841"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00011841","sets":["1169:1170"]},"author_link":["36271","36272","36273","36274"],"item_1628147817048":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-06-17","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"827","bibliographicPageStart":"825","bibliographicVolumeNumber":"25","bibliographic_titles":[{"bibliographic_title":"ANALYTICAL SCIENCES"}]}]},"item_6_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An amperometric biosensor for the detection of glucosamine (GlcN) and chitosan oligosaccharides ((GlcN)(n)) was introduced for an activity measurement of chitosanase. By using the biosensor, an increase in the anodic current due to the production of GlcN and (GlcN)(n) by chitosanase was measured in a chitosan solution. The maximum value of the slope of the current increase was proportional to the enzyme concentration up to 1.4 mu g mL(-1). The present method had the advantages of being simple and rapid over the conventional Elson-Morgan method.","subitem_description_type":"Abstract"}]},"item_6_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_6_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"ANALYTICAL SCIENCES. 25(6):825-827 (2009)","subitem_description_type":"Other"}]},"item_6_link_3":{"attribute_name":"信州大学研究者総覧へのリンク","attribute_value_mlt":[{"subitem_link_text":"Tatsumi, Hirosuke","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.uCkFjFkV.html"}]},"item_6_link_67":{"attribute_name":"WoS","attribute_value_mlt":[{"subitem_link_text":"Web of Science","subitem_link_url":"http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000266944300015"}]},"item_6_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"JAPAN SOC ANALYTICAL CHEMISTRY"}]},"item_6_relation_48":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"10.2116/analsci.25.825"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.2116/analsci.25.825","subitem_relation_type_select":"DOI"}}]},"item_6_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0910-6340","subitem_source_identifier_type":"ISSN"}]},"item_6_source_id_40":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10500785","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tatsumi,  Hirosuke"}],"nameIdentifiers":[{"nameIdentifier":"36271","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Katano,  Hajime"}],"nameIdentifiers":[{"nameIdentifier":"36272","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ikeda,  Tokuji"}],"nameIdentifiers":[{"nameIdentifier":"36273","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kimoto,  Hisashi"}],"nameIdentifiers":[{"nameIdentifier":"36274","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-28"}],"displaytype":"detail","filename":"Activity_Measurement_Chitosanase_Amperometric_Biosensor.pdf","filesize":[{"value":"619.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Activity_Measurement_Chitosanase_Amperometric_Biosensor.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/11841/files/Activity_Measurement_Chitosanase_Amperometric_Biosensor.pdf"},"version_id":"d272053d-8634-4e30-b201-45769652187c"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Activity Measurement of Chitosanase by an Amperometric Biosensor","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Activity Measurement of Chitosanase by an Amperometric Biosensor","subitem_title_language":"en"}]},"item_type_id":"6","owner":"1","path":["1170"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-09-03"},"publish_date":"2012-09-03","publish_status":"0","recid":"11841","relation_version_is_last":true,"title":["Activity Measurement of Chitosanase by an Amperometric Biosensor"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-14T04:13:14.434311+00:00"}