{"created":"2021-03-01T06:15:19.691908+00:00","id":12417,"links":{},"metadata":{"_buckets":{"deposit":"30162f33-3d50-440f-831f-4da130058a2c"},"_deposit":{"id":"12417","owners":[],"pid":{"revision_id":0,"type":"depid","value":"12417"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00012417","sets":["1221:1222"]},"author_link":["37835","37836","37837","37838","37839"],"item_1628147817048":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_6_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"A Study on Magnetic Shielding Enclosure with Openings with Coil Systems"}]},"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-09-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"220","bibliographicPageStart":"215","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"日本AEM学会誌"}]}]},"item_6_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We propose a new magnetic shielding system. This magnetic shield has the shape of a hexagonal tube with an opening. Compared with a conventional cylindrical magnetic shield, this system can provide a better magnetical environment. The measured results show that the system demonstrates a special environment as 10nT (in z axis) in 32% of the residual magnetic field in the shield. Moreover, this magnetic shield combined three sets of coil system. The measured results show that the system demonstrates 100nT (in 3-axes) in 30% of the residual magnetic field in the shield.","subitem_description_type":"Abstract"}]},"item_6_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_6_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"日本AEM学会誌. 18(3):215-220 (2010)","subitem_description_type":"Other"}]},"item_6_link_3":{"attribute_name":"信州大学研究者総覧へのリンク","attribute_value_mlt":[{"subitem_link_text":"田代, 晋久","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.gVSVjefp.html"},{"subitem_link_text":"脇若, 弘之","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.OFcFZVkh.html"}]},"item_6_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本AEM学会"}]},"item_6_relation_51":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110007701276","subitem_relation_type_select":"URI"}}]},"item_6_rights_62":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright© 2010 日本AEM学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_6_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0919-4452","subitem_source_identifier_type":"ISSN"}]},"item_6_source_id_40":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10457520","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"松岡, 信仁"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"松村, 啓志郎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"久保田, 晃弘"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"田代, 晋久"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"脇若, 弘之"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-28"}],"displaytype":"detail","filename":"Magnetic_Shielding_Enclosure_Openings_Coil_Systems.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Magnetic_Shielding_Enclosure_Openings_Coil_Systems.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/12417/files/Magnetic_Shielding_Enclosure_Openings_Coil_Systems.pdf"},"version_id":"07836790-875d-4081-b4a2-29469102bf9c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"residual magnetization measurement","subitem_subject_scheme":"Other"},{"subitem_subject":"hexagonal tube","subitem_subject_scheme":"Other"},{"subitem_subject":"magnetic shielding system","subitem_subject_scheme":"Other"},{"subitem_subject":"coil system","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"コイルを組み合わせた開口部を有する磁気シールドの検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"コイルを組み合わせた開口部を有する磁気シールドの検討","subitem_title_language":"ja"}]},"item_type_id":"6","owner":"1","path":["1222"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-07-23"},"publish_date":"2012-07-23","publish_status":"0","recid":"12417","relation_version_is_last":true,"title":["コイルを組み合わせた開口部を有する磁気シールドの検討"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-14T04:01:32.884640+00:00"}