{"created":"2021-03-01T06:15:20.124814+00:00","id":12424,"links":{},"metadata":{"_buckets":{"deposit":"fcafd0b1-b555-40c1-b90e-8c9ad26dc382"},"_deposit":{"id":"12424","owners":[],"pid":{"revision_id":0,"type":"depid","value":"12424"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00012424","sets":["1221:1222"]},"author_link":["37860","37861","37862"],"item_1628147817048":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-12","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"181","bibliographicPageStart":"171","bibliographicVolumeNumber":"9","bibliographic_titles":[{"bibliographic_title":"Sensors & Transducers Journal"}]}]},"item_6_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Sensitivity limits of magnetometers with air-core pickup coils are considered through three basic principles, Faraday''s law, the definition of inductance and Ohm's law. This paper presents two simple equivalent circuit models for voltage detection and current detection, and describes their sensitivity with eight parameters. Both models require different methodology for optimal pickup coil design. The calculated results are in agreement with experimental results, and illustrate the advantages of magnetometers based on current detection model.","subitem_description_type":"Abstract"}]},"item_6_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_6_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Sensors & Transducers Journal. 9:171-181 (2010)","subitem_description_type":"Other"}]},"item_6_link_3":{"attribute_name":"信州大学研究者総覧へのリンク","attribute_value_mlt":[{"subitem_link_text":"Tashiro, Kunihisa","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.gVSVjefp.html"},{"subitem_link_text":"Wakiwaka, Hiroyuki","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.OFcFZVkh.html"}]},"item_6_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IFSA"}]},"item_6_relation_51":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.sensorsportal.com/HTML/DIGEST/P_SI_122.htm","subitem_relation_type_select":"URI"}}]},"item_6_rights_62":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2010 IFSA"}]},"item_6_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1726-5479","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tashiro, Kunihisa"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Inoue, Shin-ichiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Wakiwaka, Hiroyuki"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-28"}],"displaytype":"detail","filename":"Sensitivity_Limits_Magnetometer_Air-core.pdf","filesize":[{"value":"1.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Sensitivity_Limits_Magnetometer_Air-core.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/12424/files/Sensitivity_Limits_Magnetometer_Air-core.pdf"},"version_id":"6beeb6c9-b2e2-45a6-9c51-95fe01a3132d"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Induction magnetometer","subitem_subject_scheme":"Other"},{"subitem_subject":"Air-core coil","subitem_subject_scheme":"Other"},{"subitem_subject":"Detection model","subitem_subject_scheme":"Other"},{"subitem_subject":"Equivalent circuit","subitem_subject_scheme":"Other"},{"subitem_subject":"Sensitivity limits","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Sensitivity limits of a magnetometer with an air-core pickup coil","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Sensitivity limits of a magnetometer with an air-core pickup coil","subitem_title_language":"en"}]},"item_type_id":"6","owner":"1","path":["1222"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-07-09"},"publish_date":"2012-07-09","publish_status":"0","recid":"12424","relation_version_is_last":true,"title":["Sensitivity limits of a magnetometer with an air-core pickup coil"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-14T04:01:33.083037+00:00"}