{"created":"2021-03-01T06:15:22.374995+00:00","id":12461,"links":{},"metadata":{"_buckets":{"deposit":"38f4b1dc-5cbc-4f57-a3dd-c3821aadbb4f"},"_deposit":{"id":"12461","owners":[],"pid":{"revision_id":0,"type":"depid","value":"12461"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00012461","sets":["1221:1222"]},"author_link":["37958","37959","37960","37961","37962","37963","37964","37965","37966","37967"],"item_1628147817048":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicVolumeNumber":"81","bibliographic_titles":[{"bibliographic_title":"REVIEW OF SCIENTIFIC INSTRUMENTS"}]}]},"item_6_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We developed a spectrometer specialized for simultaneous observation of the hydrogen Balmer-alpha, -beta, -gamma lines and the Fulcher-alpha v(')=v(')=2 rovibronic transition band. The spectrometer was optimized for the light input coupled by nine optical fibers having 400 mu m core diameters. The spectral resolutions were 0.02-0.03 nm for these wavelength ranges at the entrance slit width of 20 mu m. The polarization resolved spectra of these emissions from the peripheral region of large helical device (LHD) plasmas were measured simultaneously and showed the polarization dependence coming from the magnetic field in the LHD plasma.","subitem_description_type":"Abstract"}]},"item_6_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_6_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"REVIEW OF SCIENTIFIC INSTRUMENTS. 81(3):033106 (2010)","subitem_description_type":"Other"}]},"item_6_link_3":{"attribute_name":"信州大学研究者総覧へのリンク","attribute_value_mlt":[{"subitem_link_text":"Sawada, K","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.gmTmZVkh.html"}]},"item_6_link_67":{"attribute_name":"WoS","attribute_value_mlt":[{"subitem_link_url":"http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000276210200007"}]},"item_6_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AMER INST PHYSICS"}]},"item_6_relation_48":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"10.1063/1.3356730"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1063/1.3356730","subitem_relation_type_select":"DOI"}}]},"item_6_rights_62":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright© 2010 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Rev. Sci. Instrum. 81, 033106 (2010) and may be found at https://doi.org/10.1063/1.3356730 ."}]},"item_6_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0034-6748","subitem_source_identifier_type":"ISSN"}]},"item_6_source_id_40":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00817730","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Fujii, K"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Mizushiri, K"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Nishioka, T"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shikama, T"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Iwamae, A"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Goto, M"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Morita, S"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kado, S"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sawada, K"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Hasuo, M"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-28"}],"displaytype":"detail","filename":"Development_multiwavelength-range_fine-resolution_spectrometer.pdf","filesize":[{"value":"4.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Development_multiwavelength-range_fine-resolution_spectrometer.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/12461/files/Development_multiwavelength-range_fine-resolution_spectrometer.pdf"},"version_id":"85529183-4efd-479d-b69e-1f66639cb5d9"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"plasma confinement","subitem_subject_scheme":"Other"},{"subitem_subject":"plasma devices","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Development of multiwavelength-range fine-resolution spectrometer for hydrogen emissions and its application to large helical device periphery plasmas","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of multiwavelength-range fine-resolution spectrometer for hydrogen emissions and its application to large helical device periphery plasmas","subitem_title_language":"en"}]},"item_type_id":"6","owner":"1","path":["1222"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-02-22"},"publish_date":"2012-02-22","publish_status":"0","recid":"12461","relation_version_is_last":true,"title":["Development of multiwavelength-range fine-resolution spectrometer for hydrogen emissions and its application to large helical device periphery plasmas"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-14T04:07:33.427978+00:00"}