{"created":"2021-03-01T06:15:23.902106+00:00","id":12486,"links":{},"metadata":{"_buckets":{"deposit":"90b0e979-6978-4e05-b037-80d802591495"},"_deposit":{"id":"12486","owners":[],"pid":{"revision_id":0,"type":"depid","value":"12486"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00012486","sets":["1221:1222"]},"author_link":["38100","38101","38102","38103"],"item_1628147817048":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"10","bibliographicPageEnd":"4273","bibliographicPageStart":"4270","bibliographicVolumeNumber":"47","bibliographic_titles":[{"bibliographic_title":"IEEE TRANSACTIONS ON MAGNETICS"}]}]},"item_6_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The objective of the study is a development of desk-top magnetic shielding system for the calibration of high-sensitive magnetometers, and the evaluation of their ability to produce a uniform magnetic field. This system consists of hexagonal tubes and a cylinder. The hexagonal tubes have a double-layered structure, an opening and an advantage in axial shielding performance. The cylinder has openings and an advantage in transverse shielding performance. A solenoid-like coil is wound around the hexagonal tubes to produce a uniform magnetic field. From the experimental results, the magnetic shielding and the calibration field properties are demonstrated. Within the half length of the system, the achieved total magnetic field (dc component) is less than 200 nT within ± 50 nT deviation, and the measured shielding factor is larger than 250. For producing a uniform magnetic field up to 10 kHz, we can use the 1/3 length of the system.","subitem_description_type":"Abstract"}]},"item_6_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_6_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"IEEE TRANSACTIONS ON MAGNETICS. 47(10):4270-4273 (2011)","subitem_description_type":"Other"}]},"item_6_link_3":{"attribute_name":"信州大学研究者総覧へのリンク","attribute_value_mlt":[{"subitem_link_text":"Tashiro, Kunihisa","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.gVSVjefp.html"},{"subitem_link_text":"Wakiwaka, Hiroyuki","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.OFcFZVkh.html"}]},"item_6_link_67":{"attribute_name":"WoS","attribute_value_mlt":[{"subitem_link_url":"http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000296418200499"}]},"item_6_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC"}]},"item_6_relation_48":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"10.1109/TMAG.2011.2144572"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1109/TMAG.2011.2144572","subitem_relation_type_select":"DOI"}}]},"item_6_rights_62":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright© 2011 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works."}]},"item_6_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0018-9464","subitem_source_identifier_type":"ISSN"}]},"item_6_source_id_40":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00667933","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tashiro, Kunihisa"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Wakiwaka, Hiroyuki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Matsumura, Keishiro"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Okano, Keishi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-28"}],"displaytype":"detail","filename":"Desktop_magnetic_shielding_system.pdf","filesize":[{"value":"416.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Desktop_magnetic_shielding_system.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/12486/files/Desktop_magnetic_shielding_system.pdf"},"version_id":"d89828ad-454a-4f23-89ec-43f15efbb1f7"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Magnetic shield","subitem_subject_scheme":"Other"},{"subitem_subject":"shielding factor","subitem_subject_scheme":"Other"},{"subitem_subject":"calibration field","subitem_subject_scheme":"Other"},{"subitem_subject":"uniformity of magnetic field","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Desktop Magnetic Shielding System for the Calibration of High-Sensitivity Magnetometers","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Desktop Magnetic Shielding System for the Calibration of High-Sensitivity Magnetometers","subitem_title_language":"en"}]},"item_type_id":"6","owner":"1","path":["1222"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2011-10-17"},"publish_date":"2011-10-17","publish_status":"0","recid":"12486","relation_version_is_last":true,"title":["Desktop Magnetic Shielding System for the Calibration of High-Sensitivity Magnetometers"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-14T04:07:37.513963+00:00"}