{"created":"2021-03-01T06:15:29.285996+00:00","id":12576,"links":{},"metadata":{"_buckets":{"deposit":"e7c7ece3-34af-4ae9-8ee7-d787572f6958"},"_deposit":{"id":"12576","owners":[],"pid":{"revision_id":0,"type":"depid","value":"12576"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00012576","sets":["1221:1222"]},"author_link":["38455","38456","38457"],"item_1628147817048":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"429","bibliographicPageStart":"420","bibliographicVolumeNumber":"3","bibliographic_titles":[{"bibliographic_title":"Journal of Fluid Science and Technology"}]}]},"item_6_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The aim of this investigation was to develop an environmentally friendly nano-hydraulic turbine. A model of a two-bucket Savonius type hydraulic turbine was constructed and tested in a water tunnel to arrive at an optimum installation condition. Effects of two installation parameters, namely a distance between a rotor and a bottom wall of the tunnel, a rotation direction of the rotor, on the power performance were studied. A flow field around the rotor was examined visually to clarify influences of installation conditions on the flow field. The flow visualization showed differences of flow pattern around the rotor by the change of these parameters. From this study it was found that the power performances of Savonius hydraulic turbine were changed with the distance between the rotor and the bottom wall of the tunnel and with a rotation direction of the rotor.","subitem_description_type":"Abstract"}]},"item_6_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_6_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"Journal of Fluid Science and Technology. 3(3):420-429 (2008)","subitem_description_type":"Other"}]},"item_6_link_3":{"attribute_name":"信州大学研究者総覧へのリンク","attribute_value_mlt":[{"subitem_link_text":"Iio, S","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.HecNbpkh.html"},{"subitem_link_text":"Ikeda, T","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.OCfhZhkh.html"}]},"item_6_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本機械学会"}]},"item_6_relation_48":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"10.1299/jfst.3.420"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1299/jfst.3.420","subitem_relation_type_select":"DOI"}}]},"item_6_rights_62":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright (c) 2008 社団法人日本機械学会"}]},"item_6_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1880-5558","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nakajima, M"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Iio, S"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ikeda, T"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-28"}],"displaytype":"detail","filename":"Performance_of_Savonius_Rotor_for_Environmentally_Friendly_Hydraulic_Turbine.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Performance_of_Savonius_Rotor_for_Environmentally_Friendly_Hydraulic_Turbine.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/12576/files/Performance_of_Savonius_Rotor_for_Environmentally_Friendly_Hydraulic_Turbine.pdf"},"version_id":"928773d9-1724-4391-b893-085adc8aa3b7"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Performance of Savonius Rotor for Environmentally Friendly Hydraulic Turbine","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Performance of Savonius Rotor for Environmentally Friendly Hydraulic Turbine","subitem_title_language":"en"}]},"item_type_id":"6","owner":"1","path":["1222"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2009-06-09"},"publish_date":"2009-06-09","publish_status":"0","recid":"12576","relation_version_is_last":true,"title":["Performance of Savonius Rotor for Environmentally Friendly Hydraulic Turbine"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-14T04:02:01.725994+00:00"}