{"created":"2021-03-01T06:16:08.694624+00:00","id":13221,"links":{},"metadata":{"_buckets":{"deposit":"1fa6591f-8c2f-41eb-8132-352c3078ff53"},"_deposit":{"id":"13221","owners":[],"pid":{"revision_id":0,"type":"depid","value":"13221"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00013221","sets":["1221:1223:1224:1305"]},"author_link":["40091"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1953-03-30","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"34","bibliographicPageStart":"29","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"信州大学工学部研究報告"}]}]},"item_10_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We have studied on the practical titrommeter, which is operated with A. c. line source. As the results, we have proposed the circuit of superregenera Lion type, especially of self-quench type. The principles of this type are based on the build-up-phenomena of the oscillation, effected by the load. Next, this work proposes the electrode system with distributed-constants, which is coupled to the oscillator. These systems are characterized by the two points, one being the matching operation and the other the conventional size of the electrode. The selectivity is expected fully and the accuracy is within 0.1%, on the self-quenching superregenerative titrometer of 200 Mc.","subitem_description_type":"Abstract"}]},"item_10_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_10_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"信州大学工学部研究報告 2: 29-34(1953)","subitem_description_type":"Other"}]},"item_10_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"信州大学工学部"}]},"item_10_source_id_40":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00121239","subitem_source_identifier_type":"NCID"}]},"item_1627890569677":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"石田, 光夫","creatorNameLang":"ja"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-28"}],"displaytype":"detail","filename":"Engineering02-04.pdf","filesize":[{"value":"428.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Engineering02-04.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/13221/files/Engineering02-04.pdf"},"version_id":"6a143c9d-3352-4998-9a72-0776745aedb8"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"超再生式高周波滴定装置","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"超再生式高周波滴定装置","subitem_title_language":"ja"},{"subitem_title":"SUPERREGENERATIVE TITROMETER","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["1305"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2011-02-15"},"publish_date":"2011-02-15","publish_status":"0","recid":"13221","relation_version_is_last":true,"title":["超再生式高周波滴定装置"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-03-16T02:56:16.379247+00:00"}