{"created":"2021-03-01T06:16:23.895326+00:00","id":13470,"links":{},"metadata":{"_buckets":{"deposit":"c81f77eb-c21a-401c-93cd-23e80c2a5661"},"_deposit":{"id":"13470","owners":[],"pid":{"revision_id":0,"type":"depid","value":"13470"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00013470","sets":["1309:1310"]},"author_link":["41097","41098","41099","41100"],"item_1628147817048":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_6_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Individual Modeling Method Based on the X-ray CT Images (The Correction Method of CT Values Influenced by Partial Volume Effect)"}]},"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"697","bibliographicPageEnd":"1177","bibliographicPageStart":"1170","bibliographicVolumeNumber":"70","bibliographic_titles":[{"bibliographic_title":"日本機械学会論文集. A編"}]}]},"item_6_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Individual stress analysis of a bone based on X-ray CT data provides useful information for diagnoses and medical treatments. Many studies on the stress analyses have been reported, however little attention has given to partial volume effect in the CT data. The partial volume effect may cause lower reliability in the analytical results because CT values on a bony part are changed by the effect. This paper proposes a method to correct CT values influenced by the partial volume effect. The correction method transforms CT values using a regression curve of an exponential function. The validity of the proposed method is confirmed by use of CT images of femurs of a pig and human mandibles.","subitem_description_type":"Abstract"}]},"item_6_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_6_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"日本機械学会論文集. A編. 70(697):1170-1177 (2004)","subitem_description_type":"Other"}]},"item_6_link_3":{"attribute_name":"信州大学研究者総覧へのリンク","attribute_value_mlt":[{"subitem_link_text":"小関, 道彦","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.ZenFupLV.html"}]},"item_6_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"社団法人日本機械学会"}]},"item_6_relation_51":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110004998815/","subitem_relation_type_select":"URI"}}]},"item_6_rights_62":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright (c) 2004 社団法人 日本機械学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_6_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0387-5008","subitem_source_identifier_type":"ISSN"}]},"item_6_source_id_40":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN0018742X","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小関, 道彦"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"北川, 祐介"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"伊能, 教夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"槇, 宏太郎"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-28"}],"displaytype":"detail","filename":"110004998815.pdf","filesize":[{"value":"995.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110004998815.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/13470/files/110004998815.pdf"},"version_id":"e31ce369-b860-43a8-a098-e7a8de39efa7"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Biomechanics","subitem_subject_scheme":"Other"},{"subitem_subject":"Computational Mechanics","subitem_subject_scheme":"Other"},{"subitem_subject":"Finite Element Method","subitem_subject_scheme":"Other"},{"subitem_subject":"Individual Modeling","subitem_subject_scheme":"Other"},{"subitem_subject":"X-ray CT","subitem_subject_scheme":"Other"},{"subitem_subject":"Partial Volume Effect","subitem_subject_scheme":"Other"},{"subitem_subject":"Human Mandible","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"X線CT画像に基づく骨体の個体別モデリング手法に関する研究(パーシャルボリューム効果の補正手法の提案)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"X線CT画像に基づく骨体の個体別モデリング手法に関する研究(パーシャルボリューム効果の補正手法の提案)","subitem_title_language":"ja"}]},"item_type_id":"6","owner":"1","path":["1310"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2010-01-20"},"publish_date":"2010-01-20","publish_status":"0","recid":"13470","relation_version_is_last":true,"title":["X線CT画像に基づく骨体の個体別モデリング手法に関する研究(パーシャルボリューム効果の補正手法の提案)"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-14T04:03:50.066583+00:00"}