{"created":"2021-03-01T06:16:23.956100+00:00","id":13471,"links":{},"metadata":{"_buckets":{"deposit":"5fe85b7a-0c08-44b3-b019-edff1daa1511"},"_deposit":{"id":"13471","owners":[],"pid":{"revision_id":0,"type":"depid","value":"13471"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00013471","sets":["1309:1310"]},"author_link":["41101","41102","41103"],"item_1628147817048":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_6_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Individual Modeling Method Based on the X-Ray CT Images (Influence of Partial Volume Effect on the Modeling)"}]},"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"677","bibliographicPageEnd":"114","bibliographicPageStart":"109","bibliographicVolumeNumber":"69","bibliographic_titles":[{"bibliographic_title":"日本機械学会論文集. A編"}]}]},"item_6_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Reliable stress analysis of a bone requires not only precision in shape of the finite element model but also proper setting of material constants for the model. This paper deals with estimation of Young's modulus to the finite elements based on the X-ray CT data. At first, partial volume effect on the modeling was discussed by analytical and experimental ways using acrylic cylindrical specimen. Second, a simple correction method which transforms the CT value around border of the object was proposed. In this correction method, CT value larger than the threshold value was pulled up to the target CT value. To confirm validity of the proposed correction method, a load test and stress analyses using a dry mandible were performed. Analytical displacement between condyles and maximum principal strains were well coincided with these of experiments.","subitem_description_type":"Abstract"}]},"item_6_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_6_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"日本機械学会論文集. A編. 69(677):109-114 (2003)","subitem_description_type":"Other"}]},"item_6_link_3":{"attribute_name":"信州大学研究者総覧へのリンク","attribute_value_mlt":[{"subitem_link_text":"小関, 道彦","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.ZenFupLV.html"}]},"item_6_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"社団法人日本機械学会"}]},"item_6_relation_51":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110002370280/","subitem_relation_type_select":"URI"}}]},"item_6_rights_62":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright (c) 2003 社団法人 日本機械学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_6_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0387-5008","subitem_source_identifier_type":"ISSN"}]},"item_6_source_id_40":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN0018742X","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"伊能, 教夫"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小関, 道彦"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"槇, 宏太郎"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-28"}],"displaytype":"detail","filename":"110002370280.pdf","filesize":[{"value":"818.7 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110002370280.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/13471/files/110002370280.pdf"},"version_id":"82f4fadb-983a-4fd7-b958-8a530cff026e"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Biomechanics","subitem_subject_scheme":"Other"},{"subitem_subject":"Computational Mechanics","subitem_subject_scheme":"Other"},{"subitem_subject":"Finite Element Method","subitem_subject_scheme":"Other"},{"subitem_subject":"Individual Modeling","subitem_subject_scheme":"Other"},{"subitem_subject":"X-Ray CT","subitem_subject_scheme":"Other"},{"subitem_subject":"Partial Volume Effect","subitem_subject_scheme":"Other"},{"subitem_subject":"Human Mandible","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"X線CT画像に基づく骨体の個体別モデリング手法に関する研究(部分体積効果のモデリングへの影響)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"X線CT画像に基づく骨体の個体別モデリング手法に関する研究(部分体積効果のモデリングへの影響)","subitem_title_language":"ja"}]},"item_type_id":"6","owner":"1","path":["1310"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2010-01-20"},"publish_date":"2010-01-20","publish_status":"0","recid":"13471","relation_version_is_last":true,"title":["X線CT画像に基づく骨体の個体別モデリング手法に関する研究(部分体積効果のモデリングへの影響)"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-14T04:05:47.185417+00:00"}