ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "46056cd1-fa61-4014-b6ff-b843ae6b5f47"}, "_deposit": {"id": "17254", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "17254"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00017254", "sets": []}, "author_link": ["49106"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1951-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "100", "bibliographicPageStart": "89", "bibliographicVolumeNumber": "1", "bibliographic_titles": [{"bibliographic_title": "信州大學紀要"}]}]}, "item_10_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "When the flood water pouring in a lake flowed down the river being regulated by gates, we couldn\u0027t but use the numerical integration method in calculate the variation of water level at the Lake. In this paper, the writer introduced approximately under some assumption an analytical calculation instead of numerical integration method, when the quantity of flood water varied with time linearly and all sluice gates were perfectly opened, or, the flow condition was like that in submerged weir.", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "フォーマット:mimeタイプ", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "信州大學紀要 1(1): 89-100(1951)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "信州大学"}]}, "item_10_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00219843", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "08"}]}, "item_1627890569677": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "杉尾,  捨三郎"}], "nameIdentifiers": [{"nameIdentifier": "49106", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Shinshu_Bulletin01-08.pdf", "filesize": [{"value": "675.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 675400.0, "url": {"label": "Shinshu_Bulletin01-08.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/17254/files/Shinshu_Bulletin01-08.pdf"}, "version_id": "d7907d63-5d39-4fe6-94a1-53368956254c"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "水門を有する湖沼の水位推算について", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "水門を有する湖沼の水位推算について", "subitem_title_language": "ja"}, {"subitem_title": "On the Calculation of Water Level at a Lake which has Sluice Gates", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["1678"], "permalink_uri": "http://hdl.handle.net/10091/4613", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2010-02-12"}, "publish_date": "2010-02-12", "publish_status": "0", "recid": "17254", "relation": {}, "relation_version_is_last": true, "title": ["水門を有する湖沼の水位推算について"], "weko_shared_id": -1}
  1. 900 信州大学刊行物
  2. 信州大學紀要
  3. Vol. 01 No. 1

水門を有する湖沼の水位推算について

http://hdl.handle.net/10091/4613
http://hdl.handle.net/10091/4613
1c6979a1-2b78-4620-aaac-de60a15d19fd
名前 / ファイル ライセンス アクション
Shinshu_Bulletin01-08.pdf Shinshu_Bulletin01-08.pdf (675.4 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2010-02-12
タイトル
言語 ja
タイトル 水門を有する湖沼の水位推算について
タイトル
言語 en
タイトル On the Calculation of Water Level at a Lake which has Sluice Gates
言語
言語 jpn
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
著者 杉尾, 捨三郎

× 杉尾, 捨三郎

WEKO 49106

杉尾, 捨三郎

Search repository
出版者
出版者 信州大学
引用
内容記述タイプ Other
内容記述 信州大學紀要 1(1): 89-100(1951)
書誌情報 信州大學紀要

巻 1, 号 1, p. 89-100, 発行日 1951-07
抄録
内容記述タイプ Abstract
内容記述 When the flood water pouring in a lake flowed down the river being regulated by gates, we couldn't but use the numerical integration method in calculate the variation of water level at the Lake. In this paper, the writer introduced approximately under some assumption an analytical calculation instead of numerical integration method, when the quantity of flood water varied with time linearly and all sluice gates were perfectly opened, or, the flow condition was like that in submerged weir.
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00219843
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 09:44:03.552284
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3