{"created":"2021-03-01T06:22:19.701236+00:00","id":19247,"links":{},"metadata":{"_buckets":{"deposit":"febc31f6-5070-4096-bd6e-f25dc8363c98"},"_deposit":{"id":"19247","owners":[],"pid":{"revision_id":0,"type":"depid","value":"19247"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00019247","sets":["1221:1222"]},"author_link":["104322","104323","104324","104325"],"item_1628147817048":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_6_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Design of the Magnetic Guide Magnet for Magnetic Guide of a Capsule Endoscope"}]},"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-07-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"105","bibliographicPageStart":"100","bibliographicVolumeNumber":"25","bibliographic_titles":[{"bibliographic_title":"日本AEM学会誌"}]}]},"item_6_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Movement of a capsule endoscope in body depends only on the peristalsis and gravity. Therefore, there is a problem such as prolongation of the examination time. In addition, observation of the site aimed at is not easy. It is required to control the movement of the capsule endoscope to reduce the oversight of a lesion. Towards the resolution of the problems, this research proposes a magnetic guide method using a magnetic guide magnet. It is guided the capsule endoscope by the magnetic force generated from the magnetic guide magnet. Assuming the distance between the surface of the body and digestive organ, the goal of guide distance is 100 mm. Estimates of necessary magnetic field for the guide of the capsule is 17 mT. This paper reports the design of the magnetic guide magnet which generate more than magnetic field of 17 mT to a distance of 100 mm.","subitem_description_type":"Abstract"}]},"item_6_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_6_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"日本AEM学会誌. 25(2):100-105 (2017)","subitem_description_type":"Other"}]},"item_6_link_3":{"attribute_name":"信州大学研究者総覧へのリンク","attribute_value_mlt":[{"subitem_link_text":"田代, 晋久","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.gVSVjefp.html"},{"subitem_link_text":"脇若, 弘之","subitem_link_url":"http://soar-rd.shinshu-u.ac.jp/profile/ja.OFcFZVkh.html"}]},"item_6_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本AEM学会"}]},"item_6_relation_48":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"10.14243/jsaem.25.100"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.14243/jsaem.25.100","subitem_relation_type_select":"DOI"}}]},"item_6_rights_62":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2017 The Japan Society of Applied Electromagnetics and Mechanics"}]},"item_6_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0919-4452 ","subitem_source_identifier_type":"ISSN"}]},"item_6_source_id_40":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10457520","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"田代, 晋久"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"朽名, 周平"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"脇若, 弘之"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"大宮, 直木"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-10-06"}],"displaytype":"detail","filename":"25_100.pdf","filesize":[{"value":"2.1 MB"}],"format":"application/pdf","licensefree":"© 2017 The Japan Society of Applied Electromagnetics and Mechanics","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"25_100.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/19247/files/25_100.pdf"},"version_id":"9bbfa93f-2c63-475a-af06-46443d848286"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Capsule endoscope","subitem_subject_scheme":"Other"},{"subitem_subject":"magnetic force","subitem_subject_scheme":"Other"},{"subitem_subject":"magnetic guide magnet","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"カプセル内視鏡の磁気誘導に向けた磁気誘導用磁石の設計","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"カプセル内視鏡の磁気誘導に向けた磁気誘導用磁石の設計","subitem_title_language":"ja"}]},"item_type_id":"6","owner":"1","path":["1222"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2017-10-06"},"publish_date":"2017-10-06","publish_status":"0","recid":"19247","relation_version_is_last":true,"title":["カプセル内視鏡の磁気誘導に向けた磁気誘導用磁石の設計"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-14T04:01:03.811371+00:00"}