{"created":"2021-03-01T06:10:46.551497+00:00","id":6930,"links":{},"metadata":{"_buckets":{"deposit":"52f76c83-4ff3-4663-a687-e0a9066132e3"},"_deposit":{"id":"6930","owners":[],"pid":{"revision_id":0,"type":"depid","value":"6930"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00006930","sets":["461:463:805:814"]},"author_link":["16814","16815","16816","16817"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1994-02-28","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"6","bibliographicPageStart":"1","bibliographicVolumeNumber":"19","bibliographic_titles":[{"bibliographic_title":"紀要"}]}]},"item_10_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We evaluated the correlation between plane size of red blood cell on smear and distribution of the volume measured by an automated blood cell counter. The former was measured by an automated blood cell differential analyzer, the latter by two kinds of automated cell counters based on electronic impedance method and optical method using focused laser beam. The red cell parameters seemed to be mutually related each other in detected total samples. Compared with group with normal MCV, however, the group with MCV of below 80 tend not to have the relationship between red blood cell dimension distribution or morphological changes on smear for peripheral blood and red blood cell distribution width or cell volume from both automated cell counters. The red cell paremeters measured by different counters or analyzers reflected to not only depend on red cell size but also their red cell characteristics.","subitem_description_type":"Abstract"}]},"item_10_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_10_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"紀要 19: 1-6(1994)","subitem_description_type":"Other"}]},"item_10_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"信州大学医療技術短期大学部"}]},"item_10_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385-1982","subitem_source_identifier_type":"ISSN"}]},"item_10_source_id_40":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10402438","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"高宮, 脩","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"奥村, 由美","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"笠原, 素子","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"田中, 恒二","creatorNameLang":"ja"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-25"}],"displaytype":"detail","filename":"Allied_Med19_01.pdf","filesize":[{"value":"324.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Allied_Med19_01.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/6930/files/Allied_Med19_01.pdf"},"version_id":"5be73caf-1ee8-4126-8e37-05ea3a7796dc"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"automated blood cell counter","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"automated blood cell differential analyzer","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"erythrogram","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"red cell distribution width","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"自動血球計数装置","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"自動血球分煩装置","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"赤血球分類","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"赤血球分布幅","subitem_subject_language":"ja","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"多項目自動血球計数装置による赤血球粒度分布とパターン認識法による赤血球形態との関係について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"多項目自動血球計数装置による赤血球粒度分布とパターン認識法による赤血球形態との関係について","subitem_title_language":"ja"},{"subitem_title":"Red Cell Distribution using Automated Cell Counter and Morphology of Blood Red Cells using Automated Blood Cell Differential Analyzer","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["814"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2010-03-01"},"publish_date":"2010-03-01","publish_status":"0","recid":"6930","relation_version_is_last":true,"title":["多項目自動血球計数装置による赤血球粒度分布とパターン認識法による赤血球形態との関係について"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-02-13T01:06:43.423759+00:00"}