{"created":"2021-03-01T06:11:52.558570+00:00","id":8022,"links":{},"metadata":{"_buckets":{"deposit":"7ad02bee-7d67-40ab-b85f-f3c646f60fbd"},"_deposit":{"id":"8022","owners":[],"pid":{"revision_id":0,"type":"depid","value":"8022"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00008022","sets":["882:883"]},"author_link":["22060","22061","22062","22063","22064","22065","22066"],"item_1628147817048":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_6_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicPageEnd":"509","bibliographicPageStart":"503","bibliographicVolumeNumber":"16","bibliographic_titles":[{"bibliographic_title":"JOURNAL OF ORTHOPAEDIC SCIENCE"}]}]},"item_6_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"No studies have reported on osteotomies utilizing a navigation system in congenital scoliosis surgery. This study aimed to evaluate the surgical outcomes of eight patients with congenital scoliosis or kyphoscoliosis due to hemivertebrae treated by computer-assisted hemivertebral resection using only a posterior approach. Eight consecutive patients (two scoliotics and six kyphoscoliotics) managed by computer-assisted hemivertebral resection using only a posterior approach with transpedicular instrumentation were investigated retrospectively. A CT-based navigation system was used to confirm the positions of the vertebra, spinal cord and aorta in real-time when we inserted a pedicle screw and conducted the osteotomy. The mean patient age at surgery was 18 years (range 11-41 years). The mean follow-up was 46 months (range 18-84 months). Before surgery, the mean kyphotic curve was 55.8A degrees (range 26-83A degrees), and the mean scoliotic curve was 50.0A degrees (range 36-62A degrees). At the final follow-up period, the curves averaged 23.2A degrees (range 15-40A degrees) and 31.6A degrees (range 21-44A degrees), respectively, yielding kyphotic angle corrections of 32.7A degrees (range 11-58A degrees) and Cobb angle correction rates of 36.8% (range 24.1-48.3%). A total of 72 pedicle screws were inserted with the navigation system, and two screws revealed a perforating pedicle. No neurovascular complications occurred. The perforation rate was 2.8%. Hemivertebral resection via a single posterior approach is less invasive than combined anterior and posterior approaches; however, this procedure increases the risk of spinal cord and vascular injuries. Computer-assisted hemivertebral resection enables safe and accurate performance of a hemivertebral resection via a single posterior approach.","subitem_description_type":"Abstract"}]},"item_6_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_6_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"JOURNAL OF ORTHOPAEDIC SCIENCE. 16(5):503-509 (2011)","subitem_description_type":"Other"}]},"item_6_link_3":{"attribute_name":"信州大学研究者総覧へのリンク","attribute_value_mlt":[{"subitem_link_text":"Takahashi, Jun","subitem_link_url":"https://soar-rd.shinshu-u.ac.jp/profile/ja.jeAhuakh.html"},{"subitem_link_text":"Kato, Hiroyuki","subitem_link_url":"https://soar-rd.shinshu-u.ac.jp/profile/ja.WVkCbaSp.html"}]},"item_6_link_67":{"attribute_name":"WoS","attribute_value_mlt":[{"subitem_link_text":"Web of Science","subitem_link_url":"http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000295535000004"}]},"item_6_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"SPRINGER TOKYO"}]},"item_6_relation_47":{"attribute_name":"PubMed","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"21755373"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://pubmed.ncbi.nlm.nih.gov/21755373","subitem_relation_type_select":"PMID"}}]},"item_6_relation_48":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"10.1007/s00776-011-0134-3"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1007/s00776-011-0134-3","subitem_relation_type_select":"DOI"}}]},"item_6_rights_62":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"The original publication is available at www.springerlink.com"}]},"item_6_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0949-2658","subitem_source_identifier_type":"PISSN"}]},"item_6_source_id_40":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11052566","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Takahashi, Jun","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22060","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ebara, Sohei","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22061","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hashidate, Hiroyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22062","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hirabayashi, Hiroki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22063","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ogihara, Nobuhide","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22064","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mukaiyama, Keijiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22065","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kato, Hiroyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"22066","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-25"}],"displaytype":"detail","filename":"Computer-assisted_Hemivertebra_Resection.pdf","filesize":[{"value":"571.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Computer-assisted_Hemivertebra_Resection.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/8022/files/Computer-assisted_Hemivertebra_Resection.pdf"},"version_id":"83f231d6-a9c3-4583-a4ff-37cce09b25c4"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Computer-assisted hemivertebral resection for congenital spinal deformity","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Computer-assisted hemivertebral resection for congenital spinal deformity","subitem_title_language":"en"}]},"item_type_id":"6","owner":"1","path":["883"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2014-06-20"},"publish_date":"2014-06-20","publish_status":"0","recid":"8022","relation_version_is_last":true,"title":["Computer-assisted hemivertebral resection for congenital spinal deformity"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-14T04:26:07.425746+00:00"}