Difference Between Conventional Head-pin and Dispo-pin in the Sugita Multipurpose Head Frame System

http://hdl.handle.net/10091/17642
http://hdl.handle.net/10091/17642
6ebdce9c-7478-4a00-be05-f2d3efbf8fdf
名前 / ファイル ライセンス アクション
Difference_Between_Conventional_Head-pin_Dispo-pin.pdf Difference_Between_Conventional_Head-pin_Dispo-pin.pdf (418.2 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-06-20
タイトル
タイトル Difference Between Conventional Head-pin and Dispo-pin in the Sugita Multipurpose Head Frame System
言語
言語 eng
DOI
関連識別子 https://doi.org/10.2176/nmc.53.21
関連名称 10.2176/nmc.53.21
キーワード
主題 head fixation, skull, head-pin, neurosurgery, torque
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
著者 Goto, Tetsuya

× Goto, Tetsuya

en Goto, Tetsuya

Search repository
Hongo, Kazuhiro

× Hongo, Kazuhiro

en Hongo, Kazuhiro

Search repository
信州大学研究者総覧へのリンク
氏名 Goto, Tetsuya
URL https://soar-rd.shinshu-u.ac.jp/profile/ja.jCAUHVkh.html
信州大学研究者総覧へのリンク
氏名 Hongo, Kazuhiro
URL https://soar-rd.shinshu-u.ac.jp/profile/ja.jecFHCkh.html
出版者
出版者 JAPAN NEUROSURGICAL SOC
引用
内容記述 NEUROLOGIA MEDICO-CHIRURGICA. 53(1):21-25 (2013)
書誌情報 NEUROLOGIA MEDICO-CHIRURGICA

巻 53, 号 1, p. 21-25, 発行日 2013-01
抄録
内容記述 Head fixation devices are commonly used in neurosurgical procedures and are considered essential tools for microneurosurgery. The Sugita multipurpose head frame system is one of such systems and has been used for more than 30 years worldwide. It is important to understand how to fix a patient's head with head-pins safely, because there are no numerical parameters for head-pin screwing in the Sugita frame. Recently, the Dispo-pin has been available for disposable use as a head-pin in the Sugita frame. In contrast to the conventional head-pin, the tip of the Dispo-pin is separable from the body. Although their appearance is similar, the torque for adequate fixation is different. The relationships between torque and vertical force were analyzed. The torque of the head-pin was linearly correlated with vertical force for both types of head-pin. Different conditions caused different torque increase against a specific increase of vertical force with the conventional head-pin. In contrast, torque increase against a specific increase of vertical force with the Dispo-pin was the same regardless of the situation. The torque originates from friction between the scalp and tip of the conventional head-pin. As friction is different for each patient's condition, the torque at this part is different. The friction between the tip and body of the Dispo-pin is lower than that between the scalp and tip of the head-pin. In consequence, the torque generated from the tip of the Dispo-pin is the same in each situation. It is important to understand the difference between the Dispo-pin and conventional head-pin.
資源タイプ(コンテンツの種類)
ISSN
収録物識別子タイプ EISSN
収録物識別子 0470-8105
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00358613
PubMed
識別子タイプ PMID
関連識別子 https://pubmed.ncbi.nlm.nih.gov/23358165
関連名称 23358165
権利
権利情報 Copyright© 2013 The Japan Neurosurgical Society / 本文データは学会の許諾に基づきJ-STAGEから転載したものである。
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
WoS
URL http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000314621000005
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 12:44:41.757538
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3