{"created":"2021-03-01T06:12:16.828482+00:00","id":8421,"links":{},"metadata":{"_buckets":{"deposit":"1b2e3f39-6d3e-497c-b324-c8f36145e6a6"},"_deposit":{"id":"8421","owners":[],"pid":{"revision_id":0,"type":"depid","value":"8421"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00008421","sets":["882:884:885:896"]},"author_link":["24187","24188","24189","24190"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2004-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"109","bibliographicPageStart":"104","bibliographicVolumeNumber":"32","bibliographic_titles":[{"bibliographic_title":"信州大学医学部附属病院看護研究集録"}]}]},"item_10_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"人工呼吸器加温加湿器のFisher&Paykel社製のMR730を使用しFisher&Paykel社製R206回路で、人工肺を用い各設定による回路内結露量を測定した。再生回路との結露量の差を調べた。又、回路汚染を調べた。206回路は、再生回路より結露が多く、チャンバー温は+設定にしない事が望ましい。患者の喀痰から検出された菌がチャンバーから検出された。回路汚染の予防には、結露を生じない設定と回路内の水分を排除し、逆流させない事が重要である。","subitem_description_type":"Abstract"}]},"item_10_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_10_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"信州大学医学部附属病院看護研究集録 32(1): 104-109(2004)","subitem_description_type":"Other"}]},"item_10_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"信州大学医学部附属病院看護部"}]},"item_10_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1343-3059","subitem_source_identifier_type":"ISSN"}]},"item_10_source_id_40":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11387338","subitem_source_identifier_type":"NCID"}]},"item_1627890569677":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"高尾, ゆきえ","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"壬生, 菊代","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"石井, 留美子","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小林, 利江","creatorNameLang":"ja"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-25"}],"displaytype":"detail","filename":"Nurshing_Research31-02-18.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Nurshing_Research31-02-18.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/8421/files/Nurshing_Research31-02-18.pdf"},"version_id":"51776640-209e-4757-9fe9-9783e56dee77"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"人工呼吸器回路","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"加温加湿","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"回路汚染","subitem_subject_language":"ja","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"人工呼吸器回路内結露と汚染について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"人工呼吸器回路内結露と汚染について","subitem_title_language":"ja"},{"subitem_title":"condensation of the ventilator circuit and contaminated circuit","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["896"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-03-19"},"publish_date":"2012-03-19","publish_status":"0","recid":"8421","relation_version_is_last":true,"title":["人工呼吸器回路内結露と汚染について"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-02-10T00:38:23.637670+00:00"}