{"created":"2021-03-01T06:12:18.212080+00:00","id":8444,"links":{},"metadata":{"_buckets":{"deposit":"05aac5d4-7de4-460d-902e-cd9b3eb56247"},"_deposit":{"id":"8444","owners":[],"pid":{"revision_id":0,"type":"depid","value":"8444"},"status":"published"},"_oai":{"id":"oai:soar-ir.repo.nii.ac.jp:00008444","sets":["882:884:885:897"]},"author_link":["24275","24276","24277","24278","24279","24280"],"item_10_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"149","bibliographicPageStart":"143","bibliographicVolumeNumber":"31","bibliographic_titles":[{"bibliographic_title":"信州大学医学部附属病院看護研究集録"}]}]},"item_10_description_20":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"人工肺を用いて,人工呼吸器の加温加湿器Fisher & Paykel社製のMR730の適正な設定を検討した。設定温度9パターンの口元の温度・湿度・口元への垂れ込み量及び回路内の結露・気化量を測定した。今回の実験結果から人工呼吸器の加温加湿器の設定は『37℃・+2.39℃・-2.39℃・±0』が適していると考える。しかし,人工肺での単発の実験結果であり,患者の状態・病室内の環境によって設定を変化させる必要がある。","subitem_description_type":"Abstract"}]},"item_10_description_30":{"attribute_name":"資源タイプ(コンテンツの種類)","attribute_value_mlt":[{"subitem_description":"Article","subitem_description_type":"Other"}]},"item_10_description_5":{"attribute_name":"引用","attribute_value_mlt":[{"subitem_description":"信州大学医学部附属病院看護研究集録 31(1): 143-149(2003)","subitem_description_type":"Other"}]},"item_10_publisher_4":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"信州大学医学部附属病院看護部"}]},"item_10_source_id_35":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1343-3059","subitem_source_identifier_type":"ISSN"}]},"item_10_source_id_40":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11387338","subitem_source_identifier_type":"NCID"}]},"item_1627890569677":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"壬生, 菊代","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"石井, 留美子","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"橋本, みづほ","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"中村, 歩子","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"高尾, ゆきえ","creatorNameLang":"ja"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"楊箸, 隆哉","creatorNameLang":"ja"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-09-25"}],"displaytype":"detail","filename":"Nurshing_Research31-01-21.pdf","filesize":[{"value":"891.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Nurshing_Research31-01-21.pdf","url":"https://soar-ir.repo.nii.ac.jp/record/8444/files/Nurshing_Research31-01-21.pdf"},"version_id":"78f8f14b-8e81-4754-ac64-43c073f0f09f"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"人工呼吸器","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"加温加湿器","subitem_subject_language":"ja","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"人工呼吸器の加温加湿効果について","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"人工呼吸器の加温加湿効果について","subitem_title_language":"ja"},{"subitem_title":"The examination with the modellung for the setting of the respiratory humidifier","subitem_title_language":"en"}]},"item_type_id":"10","owner":"1","path":["897"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2012-03-19"},"publish_date":"2012-03-19","publish_status":"0","recid":"8444","relation_version_is_last":true,"title":["人工呼吸器の加温加湿効果について"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-02-10T00:33:44.810604+00:00"}