{"_buckets": {"deposit": "15e87c19-0bf4-427f-b692-8d3a600cf14e"}, "_deposit": {"id": "11906", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "11906"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00011906", "sets": ["1169:1170"]}, "author_link": ["36493"], "item_1628147817048": {"attribute_name": "\u51fa\u7248\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_6_alternative_title_1": {"attribute_name": "\u305d\u306e\u4ed6\uff08\u5225\u8a00\u8a9e\u7b49\uff09\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "Comparison between ultrasonic sieving and hydrometer methods of grain-size analysis for muddy sediments"}]}, "item_6_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1990", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "61", "bibliographicPageStart": "57", "bibliographicVolumeNumber": "33", "bibliographic_titles": [{"bibliographic_title": "\u5806\u7a4d\u5b66\u7814\u7a76\u4f1a\u5831"}]}]}, "item_6_description_20": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "The ultrasonic sieving method is a new and useful tool for grainsize analysis of fine-grained muddy sediments. The new method was compared with the traditional hydrometer method. The ultrasonic sieving method shows a little wide variation. Ultrasonic vibration is often used to disperse the sample before the hydrometer analysis. It decreasea the grainsize of muddy sediments, but the sediments attains a \"terminal distribution\" in grain size after about 30 minutes of vibration. The weigted mean of the analysis by ultrasonic sieving method is smaller than the analysis of unvibrated sample by the hydrometer method, and is concordant with the analysis of sample in terminal distribution by the hydrometer method.", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7\uff08\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u7a2e\u985e\uff09", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_31": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff1amime\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "\u5f15\u7528", "attribute_value_mlt": [{"subitem_description": "\u5806\u7a4d\u5b66\u7814\u7a76\u4f1a\u5831. 33:57-61 (1990)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "\u4fe1\u5dde\u5927\u5b66\u7814\u7a76\u8005\u7dcf\u89a7\u3078\u306e\u30ea\u30f3\u30af", "attribute_value_mlt": [{"subitem_link_text": "\u516c\u6587, \u5bcc\u58eb\u592b", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.ZUchOUkh.html"}]}, "item_6_publisher_4": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u5806\u7a4d\u5b66\u7814\u7a76\u4f1a"}]}, "item_6_select_64": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0285-1555", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0285-1555", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_40": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10553692", "subitem_source_identifier_type": "NCID"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u516c\u6587,  \u5bcc\u58eb\u592b"}], "nameIdentifiers": [{"nameIdentifier": "36493", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "taisekigaku-33.pdf", "filesize": [{"value": "433.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 433000.0, "url": {"label": "taisekigaku-33.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/11906/files/taisekigaku-33.pdf"}, "version_id": "7399d815-67a1-4238-b8a2-cf513ae2c2be"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "metaric fine-mesh filter", "subitem_subject_scheme": "Other"}, {"subitem_subject": "grain-size analysis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "hydrometer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "muddy sediment", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ultrasonic sieving", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u6ce5\u8cea\u5806\u7a4d\u7269\u306e\u7c92\u5ea6\u5206\u6790\u306b\u304a\u3051\u308b\u8d85\u97f3\u6ce2\u7be9\u5206\u6cd5\u3068\u6bd4\u91cd\u8a08\u6cd5\u306e\u6bd4\u8f03", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u6ce5\u8cea\u5806\u7a4d\u7269\u306e\u7c92\u5ea6\u5206\u6790\u306b\u304a\u3051\u308b\u8d85\u97f3\u6ce2\u7be9\u5206\u6cd5\u3068\u6bd4\u91cd\u8a08\u6cd5\u306e\u6bd4\u8f03", "subitem_title_language": "ja"}]}, "item_type_id": "6", "owner": "1", "path": ["1169/1170"], "permalink_uri": "http://hdl.handle.net/10091/3722", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2009-12-08"}, "publish_date": "2009-12-08", "publish_status": "0", "recid": "11906", "relation": {}, "relation_version_is_last": true, "title": ["\u6ce5\u8cea\u5806\u7a4d\u7269\u306e\u7c92\u5ea6\u5206\u6790\u306b\u304a\u3051\u308b\u8d85\u97f3\u6ce2\u7be9\u5206\u6cd5\u3068\u6bd4\u91cd\u8a08\u6cd5\u306e\u6bd4\u8f03"], "weko_shared_id": -1}
  1. 040 理学部
  2. 0401 学術論文

泥質堆積物の粒度分析における超音波篩分法と比重計法の比較

http://hdl.handle.net/10091/3722
f892dd74-a4cf-4f57-aa6e-ee06c7eff5d2
名前 / ファイル ライセンス アクション
taisekigaku-33.pdf taisekigaku-33.pdf (433.0 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-12-08
タイトル
言語 ja
タイトル 泥質堆積物の粒度分析における超音波篩分法と比重計法の比較
言語
言語 jpn
キーワード
主題Scheme Other
主題 metaric fine-mesh filter
キーワード
主題Scheme Other
主題 grain-size analysis
キーワード
主題Scheme Other
主題 hydrometer
キーワード
主題Scheme Other
主題 muddy sediment
キーワード
主題Scheme Other
主題 ultrasonic sieving
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
その他(別言語等)のタイトル
その他のタイトル Comparison between ultrasonic sieving and hydrometer methods of grain-size analysis for muddy sediments
著者 公文, 富士夫

× 公文, 富士夫

WEKO 36493

公文, 富士夫

Search repository
信州大学研究者総覧へのリンク
氏名 公文, 富士夫
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.ZUchOUkh.html
出版者
出版者 堆積学研究会
引用
内容記述タイプ Other
内容記述 堆積学研究会報. 33:57-61 (1990)
書誌情報 堆積学研究会報

巻 33, p. 57-61, 発行日 1990
抄録
内容記述タイプ Abstract
内容記述 The ultrasonic sieving method is a new and useful tool for grainsize analysis of fine-grained muddy sediments. The new method was compared with the traditional hydrometer method. The ultrasonic sieving method shows a little wide variation. Ultrasonic vibration is often used to disperse the sample before the hydrometer analysis. It decreasea the grainsize of muddy sediments, but the sediments attains a "terminal distribution" in grain size after about 30 minutes of vibration. The weigted mean of the analysis by ultrasonic sieving method is smaller than the analysis of unvibrated sample by the hydrometer method, and is concordant with the analysis of sample in terminal distribution by the hydrometer method.
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
ISSN
収録物識別子タイプ ISSN
収録物識別子 0285-1555
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN10553692
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 11:39:17.223709
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio