WEKO3
AND
アイテム
{"_buckets": {"deposit": "05704c52-d199-4ebd-9dbe-d0b22f567cf3"}, "_deposit": {"id": "12418", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "12418"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00012418", "sets": ["1221:1222"]}, "author_link": ["37840", "37841", "37842", "37843"], "item_1628147817048": {"attribute_name": "\u51fa\u7248\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_6_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-09-10", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "S132", "bibliographicPageStart": "S129", "bibliographicVolumeNumber": "17", "bibliographic_titles": [{"bibliographic_title": "Journal of the Japan Society of Applied Electromagnetics and Mechanics"}]}]}, "item_6_description_20": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "From a human safety standpoint, metallic contaminant detection systems are necessary in the food and pharmaceutical industries. If products are packaged in metal wrappings, the standard eddy current method should not be used after packaging. Several groups have developed a SQUID based detection system which measures the remanent magnetism of contaminants. Although that system can satisfy requirements, liquid nitrogen maintenance or a cryocooler is needed. Here we present a novel detection system based on an induction gradiometer. This system is free from heavy cooling system, and the magnetic sensor consists of air-cored coils and simple electronics only.", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7\uff08\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u7a2e\u985e\uff09", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "\u5f15\u7528", "attribute_value_mlt": [{"subitem_description": "Journal of the Japan Society of Applied Electromagnetics and Mechanics. 17:S129-S132 (2009)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "\u4fe1\u5dde\u5927\u5b66\u7814\u7a76\u8005\u7dcf\u89a7\u3078\u306e\u30ea\u30f3\u30af", "attribute_value_mlt": [{"subitem_link_text": "Tashiro, K", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.gVSVjefp.html"}, {"subitem_link_text": "Wakiwaka, H", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.OFcFZVkh.html"}]}, "item_6_publisher_4": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "the Japan Society of Applied Electromagnetics and Mechanics"}]}, "item_6_relation_51": {"attribute_name": "\u7570\u7248\u3067\u3042\u308b", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110007360753", "subitem_relation_type_select": "URI"}}]}, "item_6_rights_62": {"attribute_name": "\u6a29\u5229", "attribute_value_mlt": [{"subitem_rights": "Copyright\u00a9 2009 \u65e5\u672cAEM\u5b66\u4f1a"}, {"subitem_rights": "\u672c\u6587\u30c7\u30fc\u30bf\u306f\u5b66\u5354\u4f1a\u306e\u8a31\u8afe\u306b\u57fa\u3065\u304dCiNii\u304b\u3089\u8907\u88fd\u3057\u305f\u3082\u306e\u3067\u3042\u308b"}]}, "item_6_select_64": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0919-4452", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0919-4452", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_40": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10457520", "subitem_source_identifier_type": "NCID"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tashiro, K"}], "nameIdentifiers": [{"nameIdentifier": "37840", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kakiuchi, A"}], "nameIdentifiers": [{"nameIdentifier": "37841", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuoka, A"}], "nameIdentifiers": [{"nameIdentifier": "37842", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wakiwaka, H"}], "nameIdentifiers": [{"nameIdentifier": "37843", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Magnetic_Contamination_Detection_System.pdf", "filesize": [{"value": "856.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 856200.0, "url": {"label": "Magnetic_Contamination_Detection_System.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/12418/files/Magnetic_Contamination_Detection_System.pdf"}, "version_id": "ed106f9f-bd89-457a-b2a1-32290dadd2cd"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "food inspection", "subitem_subject_scheme": "Other"}, {"subitem_subject": "magnetic contamination detection system", "subitem_subject_scheme": "Other"}, {"subitem_subject": "induction gradiometer", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A magnetic Contamination Detection System Based on a High Sensitivity Induction Gradiometer", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "A magnetic Contamination Detection System Based on a High Sensitivity Induction Gradiometer", "subitem_title_language": "en"}]}, "item_type_id": "6", "owner": "1", "path": ["1221/1222"], "permalink_uri": "http://hdl.handle.net/10091/15912", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2012-07-23"}, "publish_date": "2012-07-23", "publish_status": "0", "recid": "12418", "relation": {}, "relation_version_is_last": true, "title": ["A magnetic Contamination Detection System Based on a High Sensitivity Induction Gradiometer"], "weko_shared_id": -1}
A magnetic Contamination Detection System Based on a High Sensitivity Induction Gradiometer
http://hdl.handle.net/10091/15912
4deb1696-b00d-43a2-90c9-7098b03ce0ff
名前 / ファイル | ライセンス | アクション | |
---|---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-07-23 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | A magnetic Contamination Detection System Based on a High Sensitivity Induction Gradiometer | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | food inspection | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | magnetic contamination detection system | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | induction gradiometer | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
Tashiro, K
× Tashiro, K× Kakiuchi, A× Matsuoka, A× Wakiwaka, H |
|||||
信州大学研究者総覧へのリンク | ||||||
氏名 | Tashiro, K | |||||
URL | http://soar-rd.shinshu-u.ac.jp/profile/ja.gVSVjefp.html | |||||
信州大学研究者総覧へのリンク | ||||||
氏名 | Wakiwaka, H | |||||
URL | http://soar-rd.shinshu-u.ac.jp/profile/ja.OFcFZVkh.html | |||||
出版者 | ||||||
出版者 | the Japan Society of Applied Electromagnetics and Mechanics | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Journal of the Japan Society of Applied Electromagnetics and Mechanics. 17:S129-S132 (2009) | |||||
書誌情報 |
Journal of the Japan Society of Applied Electromagnetics and Mechanics 巻 17, p. S129-S132, 発行日 2009-09-10 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | From a human safety standpoint, metallic contaminant detection systems are necessary in the food and pharmaceutical industries. If products are packaged in metal wrappings, the standard eddy current method should not be used after packaging. Several groups have developed a SQUID based detection system which measures the remanent magnetism of contaminants. Although that system can satisfy requirements, liquid nitrogen maintenance or a cryocooler is needed. Here we present a novel detection system based on an induction gradiometer. This system is free from heavy cooling system, and the magnetic sensor consists of air-cored coils and simple electronics only. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0919-4452 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10457520 | |||||
異版である | ||||||
関連タイプ | isVersionOf | |||||
関連識別子 | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://ci.nii.ac.jp/naid/110007360753 | |||||
権利 | ||||||
権利情報 | Copyright© 2009 日本AEM学会 | |||||
権利 | ||||||
権利情報 | 本文データは学協会の許諾に基づきCiNiiから複製したものである | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |