{"_buckets": {"deposit": "05704c52-d199-4ebd-9dbe-d0b22f567cf3"}, "_deposit": {"id": "12418", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "12418"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00012418", "sets": ["1221:1222"]}, "author_link": ["37840", "37841", "37842", "37843"], "item_1628147817048": {"attribute_name": "\u51fa\u7248\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_6_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-09-10", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "S132", "bibliographicPageStart": "S129", "bibliographicVolumeNumber": "17", "bibliographic_titles": [{"bibliographic_title": "Journal of the Japan Society of Applied Electromagnetics and Mechanics"}]}]}, "item_6_description_20": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "From a human safety standpoint, metallic contaminant detection systems are necessary in the food and pharmaceutical industries. If products are packaged in metal wrappings, the standard eddy current method should not be used after packaging. Several groups have developed a SQUID based detection system which measures the remanent magnetism of contaminants. Although that system can satisfy requirements, liquid nitrogen maintenance or a cryocooler is needed. Here we present a novel detection system based on an induction gradiometer. This system is free from heavy cooling system, and the magnetic sensor consists of air-cored coils and simple electronics only.", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7\uff08\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u7a2e\u985e\uff09", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "\u5f15\u7528", "attribute_value_mlt": [{"subitem_description": "Journal of the Japan Society of Applied Electromagnetics and Mechanics. 17:S129-S132 (2009)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "\u4fe1\u5dde\u5927\u5b66\u7814\u7a76\u8005\u7dcf\u89a7\u3078\u306e\u30ea\u30f3\u30af", "attribute_value_mlt": [{"subitem_link_text": "Tashiro, K", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.gVSVjefp.html"}, {"subitem_link_text": "Wakiwaka, H", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.OFcFZVkh.html"}]}, "item_6_publisher_4": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "the Japan Society of Applied Electromagnetics and Mechanics"}]}, "item_6_relation_51": {"attribute_name": "\u7570\u7248\u3067\u3042\u308b", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110007360753", "subitem_relation_type_select": "URI"}}]}, "item_6_rights_62": {"attribute_name": "\u6a29\u5229", "attribute_value_mlt": [{"subitem_rights": "Copyright\u00a9 2009 \u65e5\u672cAEM\u5b66\u4f1a"}, {"subitem_rights": "\u672c\u6587\u30c7\u30fc\u30bf\u306f\u5b66\u5354\u4f1a\u306e\u8a31\u8afe\u306b\u57fa\u3065\u304dCiNii\u304b\u3089\u8907\u88fd\u3057\u305f\u3082\u306e\u3067\u3042\u308b"}]}, "item_6_select_64": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0919-4452", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0919-4452", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_40": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10457520", "subitem_source_identifier_type": "NCID"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tashiro,  K"}], "nameIdentifiers": [{"nameIdentifier": "37840", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kakiuchi,  A"}], "nameIdentifiers": [{"nameIdentifier": "37841", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuoka,  A"}], "nameIdentifiers": [{"nameIdentifier": "37842", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wakiwaka,  H"}], "nameIdentifiers": [{"nameIdentifier": "37843", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Magnetic_Contamination_Detection_System.pdf", "filesize": [{"value": "856.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 856200.0, "url": {"label": "Magnetic_Contamination_Detection_System.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/12418/files/Magnetic_Contamination_Detection_System.pdf"}, "version_id": "ed106f9f-bd89-457a-b2a1-32290dadd2cd"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "food inspection", "subitem_subject_scheme": "Other"}, {"subitem_subject": "magnetic contamination detection system", "subitem_subject_scheme": "Other"}, {"subitem_subject": "induction gradiometer", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A magnetic Contamination Detection System Based on a High Sensitivity Induction Gradiometer", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "A magnetic Contamination Detection System Based on a High Sensitivity Induction Gradiometer", "subitem_title_language": "en"}]}, "item_type_id": "6", "owner": "1", "path": ["1221/1222"], "permalink_uri": "http://hdl.handle.net/10091/15912", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2012-07-23"}, "publish_date": "2012-07-23", "publish_status": "0", "recid": "12418", "relation": {}, "relation_version_is_last": true, "title": ["A magnetic Contamination Detection System Based on a High Sensitivity Induction Gradiometer"], "weko_shared_id": -1}
  1. 060 工学部
  2. 0601 学術論文

A magnetic Contamination Detection System Based on a High Sensitivity Induction Gradiometer

http://hdl.handle.net/10091/15912
4deb1696-b00d-43a2-90c9-7098b03ce0ff
名前 / ファイル ライセンス アクション
Magnetic_Contamination_Detection_System.pdf Magnetic_Contamination_Detection_System.pdf (856.2 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-07-23
タイトル
言語 en
タイトル A magnetic Contamination Detection System Based on a High Sensitivity Induction Gradiometer
言語
言語 eng
キーワード
主題Scheme Other
主題 food inspection
キーワード
主題Scheme Other
主題 magnetic contamination detection system
キーワード
主題Scheme Other
主題 induction gradiometer
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
著者 Tashiro, K

× Tashiro, K

WEKO 37840

Tashiro, K

Search repository
Kakiuchi, A

× Kakiuchi, A

WEKO 37841

Kakiuchi, A

Search repository
Matsuoka, A

× Matsuoka, A

WEKO 37842

Matsuoka, A

Search repository
Wakiwaka, H

× Wakiwaka, H

WEKO 37843

Wakiwaka, H

Search repository
信州大学研究者総覧へのリンク
氏名 Tashiro, K
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.gVSVjefp.html
信州大学研究者総覧へのリンク
氏名 Wakiwaka, H
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.OFcFZVkh.html
出版者
出版者 the Japan Society of Applied Electromagnetics and Mechanics
引用
内容記述タイプ Other
内容記述 Journal of the Japan Society of Applied Electromagnetics and Mechanics. 17:S129-S132 (2009)
書誌情報 Journal of the Japan Society of Applied Electromagnetics and Mechanics

巻 17, p. S129-S132, 発行日 2009-09-10
抄録
内容記述タイプ Abstract
内容記述 From a human safety standpoint, metallic contaminant detection systems are necessary in the food and pharmaceutical industries. If products are packaged in metal wrappings, the standard eddy current method should not be used after packaging. Several groups have developed a SQUID based detection system which measures the remanent magnetism of contaminants. Although that system can satisfy requirements, liquid nitrogen maintenance or a cryocooler is needed. Here we present a novel detection system based on an induction gradiometer. This system is free from heavy cooling system, and the magnetic sensor consists of air-cored coils and simple electronics only.
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
ISSN
収録物識別子タイプ ISSN
収録物識別子 0919-4452
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN10457520
異版である
関連タイプ isVersionOf
関連識別子
識別子タイプ URI
関連識別子 http://ci.nii.ac.jp/naid/110007360753
権利
権利情報 Copyright© 2009 日本AEM学会
権利
権利情報 本文データは学協会の許諾に基づきCiNiiから複製したものである
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 11:27:36.788364
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio