{"_buckets": {"deposit": "130bb6f9-38e3-4228-98d3-8b2fa23a6a98"}, "_deposit": {"id": "12519", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "12519"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00012519", "sets": ["1222"]}, "author_link": ["38235", "38236", "38237", "38238", "38239"], "item_1628147817048": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_6_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "4803", "bibliographicPageStart": "4801", "bibliographicVolumeNumber": "45", "bibliographic_titles": [{"bibliographic_title": "IEEE TRANSACTIONS ON MAGNETICS"}]}]}, "item_6_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Recently, high-density printed circuit boards (HD-PCBs) with less than 50 mum/50 mum line/space has been developed. In the HD-PCB, since the spacing between adjacent signal lines becomes very small, the crosstalk electromagnetic interference among adjacent lines becomes serious. In general, in order to suppress the crosstalk, the ground line is located at the spacing between signal lines because of the decrease of mutual capacitance among adjacent signal lines. The authors have proposed a magnetic method for reducing the crosstalk. The composite magnetic material was filled in the spacing between signal lines instead of the ground line. The magnetic composite is composed of Fe-Si-B-Cr amorphous particles with a mean diameter of 6 mu m and epoxy resin. From the experiments using the PCB-TEG with a 130 mum/50 mum line/space and 25-mm line length, the crosstalk was suppressed in the wide frequency range by using the magnetic composite. In the case of using 51 vol.% amorphous composite, the crosstalk suppression was up to 20 dB around 1 GHz. The influence of the magnetic composite on the transmission and reflection in the main signal line was very small. Therefore, the proposed method is effective for crosstalk suppression without influence on the signal transmission.", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_31": {"attribute_name": "フォーマット:mimeタイプ", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "IEEE TRANSACTIONS ON MAGNETICS. 45(10):4801-4803 (2009)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "信州大学研究者総覧へのリンク", "attribute_value_mlt": [{"subitem_link_text": "Sonehara, Makoto", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.WhfCbpkh.html"}, {"subitem_link_text": "Sato, Toshiro", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.yNSNbpkh.html"}, {"subitem_link_text": "Yamasawa, Kiyohito", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.WmANWUSF.html"}, {"subitem_link_text": "Miura, Yoshimasa", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.WVfUWpSF.html"}]}, "item_6_link_67": {"attribute_name": "WoS", "attribute_value_mlt": [{"subitem_link_text": "Web of Science", "subitem_link_url": "http://gateway.isiknowledge.com/gateway/Gateway.cgi?\u0026GWVersion=2\u0026SrcAuth=ShinshuUniv\u0026SrcApp=ShinshuUniv\u0026DestLinkType=FullRecord\u0026DestApp=WOS\u0026KeyUT=000270149700355"}]}, "item_6_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC"}]}, "item_6_relation_48": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.1109/TMAG.2009.2021406"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1109/TMAG.2009.2021406", "subitem_relation_type_select": "DOI"}}]}, "item_6_rights_62": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright© 2009 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works."}]}, "item_6_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0018-9464", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0018-9464", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00667933", "subitem_source_identifier_type": "NCID"}]}, "item_6_text_69": {"attribute_name": "wosonly authkey", "attribute_value_mlt": [{"subitem_text_value": "Crosstalk; Fe-based amorphous particle; high-density printed circuit board (HD-PCB); magnetic composite"}]}, "item_6_textarea_68": {"attribute_name": "wosonly abstract", "attribute_value_mlt": [{"subitem_textarea_value": "Recently, high-density printed circuit boards (HD-PCBs) with less than 50 mu m/50 mu m line/space has been developed. In the HD-PCB, since the spacing between adjacent signal lines becomes very small, the crosstalk electromagnetic interference among adjacent lines becomes serious. In general, in order to suppress the crosstalk, the ground line is located at the spacing between signal lines because of the decrease of mutual capacitance among adjacent signal lines. The authors have proposed a magnetic method for reducing the crosstalk. The composite magnetic material was filled in the spacing between signal lines instead of the ground line. The magnetic composite is composed of Fe-Si-B-Cr amorphous particles with a mean diameter of 6 mu m and epoxy resin. From the experiments using the PCB-TEG with a 130 mu m/50 mu m line/space and 25-mm line length, the crosstalk was suppressed in the wide frequency range by using the magnetic composite. In the case of using 51 vol.% amorphous composite, the crosstalk suppression was up to 20 dB around 1 GHz. The influence of the magnetic composite on the transmission and reflection in the main signal line was very small. Therefore, the proposed method is effective for crosstalk suppression without influence on the signal transmission."}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kayama, Shinji"}], "nameIdentifiers": [{"nameIdentifier": "38235", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sonehara, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "38236", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sato, Toshiro"}], "nameIdentifiers": [{"nameIdentifier": "38237", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamasawa, Kiyohito"}], "nameIdentifiers": [{"nameIdentifier": "38238", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miura, Yoshimasa"}], "nameIdentifiers": [{"nameIdentifier": "38239", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Cross-Talk_Suppression_High_Density.pdf", "filesize": [{"value": "570.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 570600.0, "url": {"label": "Cross-Talk_Suppression_High_Density.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/12519/files/Cross-Talk_Suppression_High_Density.pdf"}, "version_id": "3efbbd85-687c-45f3-8c06-bfc79303669e"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Crosstalk", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Fe-based amorphous particle", "subitem_subject_scheme": "Other"}, {"subitem_subject": "high-density printed circuit board (HD-PCB)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "magnetic composite", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Cross-Talk Suppression in High-Density Printed Circuit Boards Using Magnetic Composite Filled in Spacing Between Signal Lines", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Cross-Talk Suppression in High-Density Printed Circuit Boards Using Magnetic Composite Filled in Spacing Between Signal Lines", "subitem_title_language": "en"}]}, "item_type_id": "6", "owner": "1", "path": ["1222"], "permalink_uri": "http://hdl.handle.net/10091/10731", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2010-10-25"}, "publish_date": "2010-10-25", "publish_status": "0", "recid": "12519", "relation": {}, "relation_version_is_last": true, "title": ["Cross-Talk Suppression in High-Density Printed Circuit Boards Using Magnetic Composite Filled in Spacing Between Signal Lines"], "weko_shared_id": -1}
Cross-Talk Suppression in High-Density Printed Circuit Boards Using Magnetic Composite Filled in Spacing Between Signal Lines
http://hdl.handle.net/10091/10731
http://hdl.handle.net/10091/10731cb2d01d2-13a2-4d85-bff0-cb14b1499363
名前 / ファイル | ライセンス | アクション |
---|---|---|
Cross-Talk_Suppression_High_Density.pdf (570.6 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-10-25 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Cross-Talk Suppression in High-Density Printed Circuit Boards Using Magnetic Composite Filled in Spacing Between Signal Lines | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題 | Crosstalk, Fe-based amorphous particle, high-density printed circuit board (HD-PCB), magnetic composite | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
Kayama, Shinji
× Kayama, Shinji× Sonehara, Makoto× Sato, Toshiro× Yamasawa, Kiyohito× Miura, Yoshimasa |
|||||
信州大学研究者総覧へのリンク | ||||||
氏名 | Sonehara, Makoto | |||||
URL | http://soar-rd.shinshu-u.ac.jp/profile/ja.WhfCbpkh.html | |||||
信州大学研究者総覧へのリンク | ||||||
氏名 | Sato, Toshiro | |||||
URL | http://soar-rd.shinshu-u.ac.jp/profile/ja.yNSNbpkh.html | |||||
信州大学研究者総覧へのリンク | ||||||
氏名 | Yamasawa, Kiyohito | |||||
URL | http://soar-rd.shinshu-u.ac.jp/profile/ja.WmANWUSF.html | |||||
信州大学研究者総覧へのリンク | ||||||
氏名 | Miura, Yoshimasa | |||||
URL | http://soar-rd.shinshu-u.ac.jp/profile/ja.WVfUWpSF.html | |||||
出版者 | ||||||
出版者 | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | IEEE TRANSACTIONS ON MAGNETICS. 45(10):4801-4803 (2009) | |||||
書誌情報 |
IEEE TRANSACTIONS ON MAGNETICS 巻 45, 号 10, p. 4801-4803, 発行日 2009-10 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Recently, high-density printed circuit boards (HD-PCBs) with less than 50 mum/50 mum line/space has been developed. In the HD-PCB, since the spacing between adjacent signal lines becomes very small, the crosstalk electromagnetic interference among adjacent lines becomes serious. In general, in order to suppress the crosstalk, the ground line is located at the spacing between signal lines because of the decrease of mutual capacitance among adjacent signal lines. The authors have proposed a magnetic method for reducing the crosstalk. The composite magnetic material was filled in the spacing between signal lines instead of the ground line. The magnetic composite is composed of Fe-Si-B-Cr amorphous particles with a mean diameter of 6 mu m and epoxy resin. From the experiments using the PCB-TEG with a 130 mum/50 mum line/space and 25-mm line length, the crosstalk was suppressed in the wide frequency range by using the magnetic composite. In the case of using 51 vol.% amorphous composite, the crosstalk suppression was up to 20 dB around 1 GHz. The influence of the magnetic composite on the transmission and reflection in the main signal line was very small. Therefore, the proposed method is effective for crosstalk suppression without influence on the signal transmission. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0018-9464 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00667933 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1109/TMAG.2009.2021406 | |||||
関連名称 | 10.1109/TMAG.2009.2021406 | |||||
権利 | ||||||
権利情報 | Copyright© 2009 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. | |||||
出版タイプ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
WoS | ||||||
表示名 | Web of Science | |||||
URL | http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000270149700355 |