{"_buckets": {"deposit": "deba0913-99fe-4724-9cb3-7174d32f061d"}, "_deposit": {"id": "12987", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "12987"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00012987", "sets": []}, "author_link": ["39775", "39776", "39777"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1972-07-25", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "198", "bibliographicPageStart": "183", "bibliographicVolumeNumber": "32", "bibliographic_titles": [{"bibliographic_title": "信州大学工学部紀要"}]}]}, "item_10_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "When the contact in the insulating oil carries the high current for many hours, there is a case where the contact resistance increases considerably. In this case, sludge occurs at the contact surface. The origin of occurrence of the sludge has not been determined yet. In this study, this phenomenon is made to appear again with model contacts, and the mechanism of occurrence of the sludge, which is the first cause to worsen the electrical characteristic of the contact, is analyzed with measurments of electrical and microscopical techniques. The model contact which has the following constructions was employed in the experiment. Model Contact No. 1 : In order to obtain the high current density and the pressure at the area of real contact, the conducting area is made a point contact by putting a grain of copper between both electrodes. And to stabilize the static load, one of the electrodes is vibrated slightly by the constant frequency (60Hz). Model Contact No. 2 : The construction is the same as the No. 1 contact but one elctrode is transparent, so that it is possible to observe the phenomenon at the contacting surface directly while the current passes through there. The following became clear from these experimental results. Generally, in electrical contact, the area of real contact must be much less than the apparent area, and it can be considered that the conducting area consists of several circular contacts the radius of which is very small. (Usually, that contacting spot is called a-spot.) Therefore, the contact resistance appears owing to the constriction of the current at the microscopic area of the contact. It the high current passes through the contact, the temperature at the point of the constriction, where the current density is extremely high, can be raised sufficiently not only to soften but to melt the metal. On the other hand, in the case of the contact in the insulating oil, the magnitude of the conducting area and the number of the spots decrease owing to the oil wedge between the surfaces of both electrodes. So the contact resistance becomes high as compared with the contact exposed to air. Consequently, there are many possibilities that an a-spot is overheated by the joule heat. So that, the oil around the a-spots is decomposed by heating and carbides grow on the contact surface. From above results, the following conclusion is reached. The electrical characteristic of the contact in the insulating oil becomes worse owing to the accumulation of the carbides on the contact surfaces.", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "フォーマット:mimeタイプ", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "信州大学工学部紀要 32: 183-198 (1972)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "信州大学工学部"}]}, "item_10_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3818", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3818", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00121228", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "13"}]}, "item_1627890569677": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "永野,  泰男", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "39775", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田原,  徳夫", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "39776", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加藤,  之敏", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "39777", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Engineering32-13.pdf", "filesize": [{"value": "1.7 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 1700000.0, "url": {"label": "Engineering32-13.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/12987/files/Engineering32-13.pdf"}, "version_id": "1f5024ad-0ec8-4eb4-9434-8d3cf5e4b9d7"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "油中接触子の通電特性劣化について", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "油中接触子の通電特性劣化について", "subitem_title_language": "ja"}, {"subitem_title": "On Worsening of Electrical Characteristic of Contact in Insulating Oil", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["1275"], "permalink_uri": "http://hdl.handle.net/10091/2851", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2009-03-30"}, "publish_date": "2009-03-30", "publish_status": "0", "recid": "12987", "relation": {}, "relation_version_is_last": true, "title": ["油中接触子の通電特性劣化について"], "weko_shared_id": -1}
  1. 060 工学部
  2. 0602 紀要
  3. 06021 信州大学工学部紀要
  4. Vol. 32

油中接触子の通電特性劣化について

http://hdl.handle.net/10091/2851
http://hdl.handle.net/10091/2851
a9a59324-95a8-4cf6-ad01-ed11b966f4a1
名前 / ファイル ライセンス アクション
Engineering32-13.pdf Engineering32-13.pdf (1.7 MB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2009-03-30
タイトル
言語 ja
タイトル 油中接触子の通電特性劣化について
タイトル
言語 en
タイトル On Worsening of Electrical Characteristic of Contact in Insulating Oil
言語
言語 jpn
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
著者 永野, 泰男

× 永野, 泰男

WEKO 39775

ja 永野, 泰男

Search repository
田原, 徳夫

× 田原, 徳夫

WEKO 39776

ja 田原, 徳夫

Search repository
加藤, 之敏

× 加藤, 之敏

WEKO 39777

ja 加藤, 之敏

Search repository
出版者
出版者 信州大学工学部
引用
内容記述タイプ Other
内容記述 信州大学工学部紀要 32: 183-198 (1972)
書誌情報 信州大学工学部紀要

巻 32, p. 183-198, 発行日 1972-07-25
抄録
内容記述タイプ Abstract
内容記述 When the contact in the insulating oil carries the high current for many hours, there is a case where the contact resistance increases considerably. In this case, sludge occurs at the contact surface. The origin of occurrence of the sludge has not been determined yet. In this study, this phenomenon is made to appear again with model contacts, and the mechanism of occurrence of the sludge, which is the first cause to worsen the electrical characteristic of the contact, is analyzed with measurments of electrical and microscopical techniques. The model contact which has the following constructions was employed in the experiment. Model Contact No. 1 : In order to obtain the high current density and the pressure at the area of real contact, the conducting area is made a point contact by putting a grain of copper between both electrodes. And to stabilize the static load, one of the electrodes is vibrated slightly by the constant frequency (60Hz). Model Contact No. 2 : The construction is the same as the No. 1 contact but one elctrode is transparent, so that it is possible to observe the phenomenon at the contacting surface directly while the current passes through there. The following became clear from these experimental results. Generally, in electrical contact, the area of real contact must be much less than the apparent area, and it can be considered that the conducting area consists of several circular contacts the radius of which is very small. (Usually, that contacting spot is called a-spot.) Therefore, the contact resistance appears owing to the constriction of the current at the microscopic area of the contact. It the high current passes through the contact, the temperature at the point of the constriction, where the current density is extremely high, can be raised sufficiently not only to soften but to melt the metal. On the other hand, in the case of the contact in the insulating oil, the magnitude of the conducting area and the number of the spots decrease owing to the oil wedge between the surfaces of both electrodes. So the contact resistance becomes high as compared with the contact exposed to air. Consequently, there are many possibilities that an a-spot is overheated by the joule heat. So that, the oil around the a-spots is decomposed by heating and carbides grow on the contact surface. From above results, the following conclusion is reached. The electrical characteristic of the contact in the insulating oil becomes worse owing to the accumulation of the carbides on the contact surfaces.
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
ISSN
収録物識別子タイプ ISSN
収録物識別子 0037-3818
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00121228
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 11:13:35.877013
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3