{"_buckets": {"deposit": "1b5ad8cd-5a70-47fe-a651-66569283c3a4"}, "_deposit": {"id": "13059", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "13059"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00013059"}, "item_10_alternative_title_1": {"attribute_name": "\u305d\u306e\u4ed6\uff08\u5225\u8a00\u8a9e\u7b49\uff09\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "Thermo-Bias Recording in CrO\u2082 Tapes"}]}, "item_10_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1969-07-25", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "291", "bibliographicPageStart": "287", "bibliographicVolumeNumber": "26", "bibliographic_titles": [{"bibliographic_title": "\u4fe1\u5dde\u5927\u5b66\u5de5\u5b66\u90e8\u7d00\u8981"}]}]}, "item_10_description_20": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "The auther measured the thermoremanent magnetization of a CrO\u2082 tape having a low Curie temperature 126\u2103, and wants to call the process by the term \u0027thermo-bias recording\u0027 This process has such some more excellent features than high frequency bias recording, as follows, (1) Recording sensitivity has been highly improved. (2) Erasing circuit is neglected. (3) This process will easily be applied to magnetic printing by utilizing the print-through effect, and this method will also be expected to better the recording sensitivity.", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7\uff08\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u7a2e\u985e\uff09", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff1amime\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "\u5f15\u7528", "attribute_value_mlt": [{"subitem_description": "\u4fe1\u5dde\u5927\u5b66\u5de5\u5b66\u90e8\u7d00\u8981 26: 287-291 (1969)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u4fe1\u5dde\u5927\u5b66\u5de5\u5b66\u90e8"}]}, "item_10_select_64": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3818", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3818", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_40": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00121228", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "15"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u677e\u672c, \u5149\u529f"}], "nameIdentifiers": [{"nameIdentifier": "39891", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Engineering26-15.pdf", "filesize": [{"value": "340.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 340600.0, "url": {"label": "Engineering26-15.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/13059/files/Engineering26-15.pdf"}, "version_id": "b9cffc18-bfac-47fb-9c14-549f4634d2c1"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u4e8c\u9178\u5316\u30af\u30ed\u30e0\u3092\u7528\u3044\u305f\u71b1\u30d0\u30a4\u30a2\u30b9\u8a18\u9332", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u4e8c\u9178\u5316\u30af\u30ed\u30e0\u3092\u7528\u3044\u305f\u71b1\u30d0\u30a4\u30a2\u30b9\u8a18\u9332"}]}, "item_type_id": "10", "owner": "1", "path": ["1221/1223/1224/1281"], "permalink_uri": "http://hdl.handle.net/10091/2119", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2009-03-03"}, "publish_date": "2009-03-03", "publish_status": "0", "recid": "13059", "relation": {}, "relation_version_is_last": true, "title": ["\u4e8c\u9178\u5316\u30af\u30ed\u30e0\u3092\u7528\u3044\u305f\u71b1\u30d0\u30a4\u30a2\u30b9\u8a18\u9332"], "weko_shared_id": null}
二酸化クロムを用いた熱バイアス記録
http://hdl.handle.net/10091/2119
abef1600-556d-46f5-8409-869ab9d0f84f
名前 / ファイル | ライセンス | アクション | |
---|---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-03-03 | |||||
タイトル | ||||||
タイトル | 二酸化クロムを用いた熱バイアス記録 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | Thermo-Bias Recording in CrO₂ Tapes | |||||
著者 |
松本, 光功
× 松本, 光功 |
|||||
出版者 | ||||||
出版者 | 信州大学工学部 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 信州大学工学部紀要 26: 287-291 (1969) | |||||
書誌情報 |
信州大学工学部紀要 巻 26, p. 287-291, 発行日 1969-07-25 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The auther measured the thermoremanent magnetization of a CrO₂ tape having a low Curie temperature 126℃, and wants to call the process by the term 'thermo-bias recording' This process has such some more excellent features than high frequency bias recording, as follows, (1) Recording sensitivity has been highly improved. (2) Erasing circuit is neglected. (3) This process will easily be applied to magnetic printing by utilizing the print-through effect, and this method will also be expected to better the recording sensitivity. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0037-3818 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00121228 |