{"_buckets": {"deposit": "0765829e-d9de-42f6-b056-94310f24b401"}, "_deposit": {"id": "13183", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "13183"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00013183"}, "item_10_alternative_title_1": {"attribute_name": "\u305d\u306e\u4ed6\uff08\u5225\u8a00\u8a9e\u7b49\uff09\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "DIFFERENTIAL ELECTRICAL THERMOMETER FOR MEASURING TEMPERATURE DISTRIBUTION"}]}, "item_10_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1956-12-25", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "46", "bibliographicPageStart": "37", "bibliographicVolumeNumber": "6", "bibliographic_titles": [{"bibliographic_title": "\u4fe1\u5dde\u5927\u5b66\u5de5\u5b66\u90e8\u7d00\u8981"}]}]}, "item_10_description_20": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "In order to measure the temperature distribution in an oil well and an ocean, the author made an differential electrical thermometer using a semiconductor and an electric hydrobarometer. The thermometer is simple in structure and its accuracy is 5/1000\uff5e1/100 \u2103 in differential temperature. The semiconductor element is of rod type having the volume of 3\u00d73\u00d74 mm\u00b3. The author measured the temperature distribution in water of a tank and liquids of the oil well at Nishiyama oil fields of Teikoku Sekiyu Co. According to these measurements, the temperature distribution in the well gives the data of oil layers and others. The electric hydrobarometer indicates, directly and continuously, the depth by converting the displacement of a Bourdon tube caused by hydropressure to the change of electric resistance. This hydrobarometer can measure the depth of 0\uff5e40, 30\uff5e800 meters. The temperature distribution in a sea, a river, etc. can also be measured by means of the hydrobarometer in combination with the thermometer. The author measured a temperature-depth characteristic at a dam of 9 meters deep.", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7\uff08\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u7a2e\u985e\uff09", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff1amime\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "\u5f15\u7528", "attribute_value_mlt": [{"subitem_description": "\u4fe1\u5dde\u5927\u5b66\u5de5\u5b66\u90e8\u7d00\u8981 6: 37-46 (1956)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u4fe1\u5dde\u5927\u5b66\u5de5\u5b66\u90e8"}]}, "item_10_select_64": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3818", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3818", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_40": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00121228", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "04"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u5c0f\u5c71,  \u6052\u592b"}], "nameIdentifiers": [{"nameIdentifier": "40045", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Engineering06-04.pdf", "filesize": [{"value": "848.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 848900.0, "url": {"label": "Engineering06-04.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/13183/files/Engineering06-04.pdf"}, "version_id": "cd5f57be-d8e5-41d3-9f4a-f83ec9a9ee1b"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u5fae\u5c0f\u6e29\u5ea6\u5dee\u6e2c\u5b9a\u5668", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u5fae\u5c0f\u6e29\u5ea6\u5dee\u6e2c\u5b9a\u5668"}]}, "item_type_id": "10", "owner": "1", "path": ["1221/1223/1224/1301"], "permalink_uri": "http://hdl.handle.net/10091/2868", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2009-03-30"}, "publish_date": "2009-03-30", "publish_status": "0", "recid": "13183", "relation": {}, "relation_version_is_last": true, "title": ["\u5fae\u5c0f\u6e29\u5ea6\u5dee\u6e2c\u5b9a\u5668"], "weko_shared_id": null}
  1. 060 工学部
  2. 0602 紀要
  3. 06021 信州大学工学部紀要
  4. Vol. 06

微小温度差測定器

http://hdl.handle.net/10091/2868
8c4acdc6-2c4a-4264-975b-396aa9fd6e9f
名前 / ファイル ライセンス アクション
Engineering06-04.pdf Engineering06-04.pdf (848.9 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2009-03-30
タイトル
タイトル 微小温度差測定器
言語
言語 jpn
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
その他(別言語等)のタイトル
その他のタイトル DIFFERENTIAL ELECTRICAL THERMOMETER FOR MEASURING TEMPERATURE DISTRIBUTION
著者 小山, 恒夫

× 小山, 恒夫

WEKO 40045

小山, 恒夫

Search repository
出版者
出版者 信州大学工学部
引用
内容記述タイプ Other
内容記述 信州大学工学部紀要 6: 37-46 (1956)
書誌情報 信州大学工学部紀要

巻 6, p. 37-46, 発行日 1956-12-25
抄録
内容記述タイプ Abstract
内容記述 In order to measure the temperature distribution in an oil well and an ocean, the author made an differential electrical thermometer using a semiconductor and an electric hydrobarometer. The thermometer is simple in structure and its accuracy is 5/1000~1/100 ℃ in differential temperature. The semiconductor element is of rod type having the volume of 3×3×4 mm³. The author measured the temperature distribution in water of a tank and liquids of the oil well at Nishiyama oil fields of Teikoku Sekiyu Co. According to these measurements, the temperature distribution in the well gives the data of oil layers and others. The electric hydrobarometer indicates, directly and continuously, the depth by converting the displacement of a Bourdon tube caused by hydropressure to the change of electric resistance. This hydrobarometer can measure the depth of 0~40, 30~800 meters. The temperature distribution in a sea, a river, etc. can also be measured by means of the hydrobarometer in combination with the thermometer. The author measured a temperature-depth characteristic at a dam of 9 meters deep.
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
ISSN
収録物識別子タイプ ISSN
収録物識別子 0037-3818
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00121228
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 11:08:49.476666
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio