WEKO3
アイテム
{"_buckets": {"deposit": "13b9b65f-fab6-495b-bc41-f48903ece7a6"}, "_deposit": {"id": "13183", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "13183"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00013183", "sets": []}, "author_link": ["40045"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1956-12-25", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "46", "bibliographicPageStart": "37", "bibliographicVolumeNumber": "6", "bibliographic_titles": [{"bibliographic_title": "信州大学工学部紀要"}]}]}, "item_10_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In order to measure the temperature distribution in an oil well and an ocean, the author made an differential electrical thermometer using a semiconductor and an electric hydrobarometer. The thermometer is simple in structure and its accuracy is 5/1000~1/100 ℃ in differential temperature. The semiconductor element is of rod type having the volume of 3×3×4 mm³. The author measured the temperature distribution in water of a tank and liquids of the oil well at Nishiyama oil fields of Teikoku Sekiyu Co. According to these measurements, the temperature distribution in the well gives the data of oil layers and others. The electric hydrobarometer indicates, directly and continuously, the depth by converting the displacement of a Bourdon tube caused by hydropressure to the change of electric resistance. This hydrobarometer can measure the depth of 0~40, 30~800 meters. The temperature distribution in a sea, a river, etc. can also be measured by means of the hydrobarometer in combination with the thermometer. The author measured a temperature-depth characteristic at a dam of 9 meters deep.", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "フォーマット:mimeタイプ", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "信州大学工学部紀要 6: 37-46 (1956)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "信州大学工学部"}]}, "item_10_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3818", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3818", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00121228", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "04"}]}, "item_1627890569677": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "小山, 恒夫", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "40045", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Engineering06-04.pdf", "filesize": [{"value": "848.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 848900.0, "url": {"label": "Engineering06-04.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/13183/files/Engineering06-04.pdf"}, "version_id": "9b4ae2ea-c38b-48c1-931e-901a3a7bc2e6"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "微小温度差測定器", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "微小温度差測定器", "subitem_title_language": "ja"}, {"subitem_title": "DIFFERENTIAL ELECTRICAL THERMOMETER FOR MEASURING TEMPERATURE DISTRIBUTION", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["1301"], "permalink_uri": "http://hdl.handle.net/10091/2868", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2009-03-30"}, "publish_date": "2009-03-30", "publish_status": "0", "recid": "13183", "relation": {}, "relation_version_is_last": true, "title": ["微小温度差測定器"], "weko_shared_id": -1}
微小温度差測定器
http://hdl.handle.net/10091/2868
http://hdl.handle.net/10091/28688c4acdc6-2c4a-4264-975b-396aa9fd6e9f
名前 / ファイル | ライセンス | アクション |
---|---|---|
Engineering06-04.pdf (848.9 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-03-30 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 微小温度差測定器 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | DIFFERENTIAL ELECTRICAL THERMOMETER FOR MEASURING TEMPERATURE DISTRIBUTION | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
著者 |
小山, 恒夫
× 小山, 恒夫 |
|||||
出版者 | ||||||
出版者 | 信州大学工学部 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 信州大学工学部紀要 6: 37-46 (1956) | |||||
書誌情報 |
信州大学工学部紀要 巻 6, p. 37-46, 発行日 1956-12-25 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In order to measure the temperature distribution in an oil well and an ocean, the author made an differential electrical thermometer using a semiconductor and an electric hydrobarometer. The thermometer is simple in structure and its accuracy is 5/1000~1/100 ℃ in differential temperature. The semiconductor element is of rod type having the volume of 3×3×4 mm³. The author measured the temperature distribution in water of a tank and liquids of the oil well at Nishiyama oil fields of Teikoku Sekiyu Co. According to these measurements, the temperature distribution in the well gives the data of oil layers and others. The electric hydrobarometer indicates, directly and continuously, the depth by converting the displacement of a Bourdon tube caused by hydropressure to the change of electric resistance. This hydrobarometer can measure the depth of 0~40, 30~800 meters. The temperature distribution in a sea, a river, etc. can also be measured by means of the hydrobarometer in combination with the thermometer. The author measured a temperature-depth characteristic at a dam of 9 meters deep. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0037-3818 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00121228 | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |