WEKO3
AND
アイテム
{"_buckets": {"deposit": "f279c609-31f4-4309-82d0-28e2587fb7fa"}, "_deposit": {"id": "17221", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "17221"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00017221"}, "item_10_alternative_title_1": {"attribute_name": "\u305d\u306e\u4ed6\uff08\u5225\u8a00\u8a9e\u7b49\uff09\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "Electric Drymeter"}]}, "item_10_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1953-05-30", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "167", "bibliographicPageStart": "155", "bibliographicVolumeNumber": "3", "bibliographic_titles": [{"bibliographic_title": "\u4fe1\u5dde\u5927\u5b78\u7d00\u8981"}]}]}, "item_10_description_20": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "For the purpose of, quality control, improvements of working efficiency and production process or to elliminate the troubles on commerce.It\u0027s desired to measure the dryness or water contents of the raw materials or manufactured goods. We have studied on the measurements and design of the practical apparatus,stand on the electrical methods.The results obtained are as follows;1. to the drymeter of wood,we proposed the resistance method employing the conducting rubber as electrodes and a megger. 2. to the water contents meter of pulp or drymeter for the paper and tobacco\uff0cthe capacity method were employed\uff0cespecially\uff0cthe substitution method and the direct reading capacity meter\uff0cwas analysed\uff0cand proposed the electrode system of grid type\uff0cwhich has no influence by the thickness variation of the sample\uff0cand give the design and some application on the analysis of the internal distributions of water contents. 3\uff0eas the result of analysis of errors due to measurements,sampling,and calibration,the overall errors of the apparatus axe expected within 2\uff05\uff0e 4\uff0epractical tests of the apparatus were proceeded at the pulp manufacturing Co.and the tobacco manufacturing Co,especially with the self recorder type drymeter\uff0cachieved the successful results\uff0e", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7\uff08\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u7a2e\u985e\uff09", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff1amime\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "\u5f15\u7528", "attribute_value_mlt": [{"subitem_description": "\u4fe1\u5dde\u5927\u5b78\u7d00\u8981 (3): 155-167(1953)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u4fe1\u5dde\u5927\u5b66"}]}, "item_10_select_64": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_40": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00219843", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "13"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u77f3\u7530, \u5149\u592b"}], "nameIdentifiers": [{"nameIdentifier": "49052", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Shinshu_Bulletin03-13.pdf", "filesize": [{"value": "1.6 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1600000.0, "url": {"label": "Shinshu_Bulletin03-13.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/17221/files/Shinshu_Bulletin03-13.pdf"}, "version_id": "855f01ec-5d58-4d94-9fb7-9bdcffb73d4b"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u96fb\u6c17\u7684\u4e7e\u71e5\u5ea6\u8a08\u306e\u7814\u7a76", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u96fb\u6c17\u7684\u4e7e\u71e5\u5ea6\u8a08\u306e\u7814\u7a76"}]}, "item_type_id": "10", "owner": "1", "path": ["1628/1674/1676"], "permalink_uri": "http://hdl.handle.net/10091/4647", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2010-02-12"}, "publish_date": "2010-02-12", "publish_status": "0", "recid": "17221", "relation": {}, "relation_version_is_last": true, "title": ["\u96fb\u6c17\u7684\u4e7e\u71e5\u5ea6\u8a08\u306e\u7814\u7a76"], "weko_shared_id": null}
電気的乾燥度計の研究
http://hdl.handle.net/10091/4647
b264d7d7-9e39-40ed-a68f-008f5849e7e2
名前 / ファイル | ライセンス | アクション | |
---|---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-02-12 | |||||
タイトル | ||||||
タイトル | 電気的乾燥度計の研究 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | Electric Drymeter | |||||
著者 |
石田, 光夫
× 石田, 光夫 |
|||||
出版者 | ||||||
出版者 | 信州大学 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 信州大學紀要 (3): 155-167(1953) | |||||
書誌情報 |
信州大學紀要 巻 3, p. 155-167, 発行日 1953-05-30 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | For the purpose of, quality control, improvements of working efficiency and production process or to elliminate the troubles on commerce.It's desired to measure the dryness or water contents of the raw materials or manufactured goods. We have studied on the measurements and design of the practical apparatus,stand on the electrical methods.The results obtained are as follows;1. to the drymeter of wood,we proposed the resistance method employing the conducting rubber as electrodes and a megger. 2. to the water contents meter of pulp or drymeter for the paper and tobacco,the capacity method were employed,especially,the substitution method and the direct reading capacity meter,was analysed,and proposed the electrode system of grid type,which has no influence by the thickness variation of the sample,and give the design and some application on the analysis of the internal distributions of water contents. 3.as the result of analysis of errors due to measurements,sampling,and calibration,the overall errors of the apparatus axe expected within 2%. 4.practical tests of the apparatus were proceeded at the pulp manufacturing Co.and the tobacco manufacturing Co,especially with the self recorder type drymeter,achieved the successful results. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00219843 |