{"_buckets": {"deposit": "af5b9f8c-1a9c-4196-9de1-d3ea1ae7eadb"}, "_deposit": {"id": "17239", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "17239"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00017239"}, "item_10_alternative_title_1": {"attribute_name": "\u305d\u306e\u4ed6\uff08\u5225\u8a00\u8a9e\u7b49\uff09\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "AN FREQUENCY ADJUSTING SYSTEM FOR STANDARD FREQUENCY"}]}, "item_10_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1952-07", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "153", "bibliographicPageStart": "149", "bibliographicVolumeNumber": "2", "bibliographic_titles": [{"bibliographic_title": "\u4fe1\u5dde\u5927\u5b78\u7d00\u8981"}]}]}, "item_10_description_20": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "The frequency adjusting system described in this paper is newly developed and designd for the purpose of quick and precise adjusting of the frequency deviation of the tuing bar oscilltor for the-standard frequency. Heretofore, the usual method of adjusting of frequency of the tuning bar oscilltors is the one which is worked by hand, for example observing the Lissajous figure produced by cathode-ray tube. This method, however, is unsuitable for the purpose of quick and precise adjustment. The main component elements of the newly developed system are tuning bar filter, amplitude limitter, frequency mixer, frequency control coil which attached close by the tuning bar\uff0cetc. If there is any difference in both frequency\uff0cthe beat frequency is obtained at the output of the mixer. After the beat current is rectified\u3000and changed to direct current\uff0cthis rectfied current flows into control coil. The frequency of the tuning bar changes due to the changing of the control coil\uff0cand is automotically synchoronized to the standard frequency, and then the rectfied current becomes certain constant value. Now, by flowing the same value of direct current as that rectfied current into the control coil, by turning ti the another direct electric source, the synchoronization of both frequency is completed quickly and precisely\uff0e", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7\uff08\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u7a2e\u985e\uff09", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff1amime\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "\u5f15\u7528", "attribute_value_mlt": [{"subitem_description": "\u4fe1\u5dde\u5927\u5b78\u7d00\u8981 (2): 149-153(1952)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u4fe1\u5dde\u5927\u5b66"}]}, "item_10_select_64": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_40": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00219843", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "14"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u6728\u6751,  \u745e\u96c4"}], "nameIdentifiers": [{"nameIdentifier": "49081", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Shinshu_Bulletin02-14.pdf", "filesize": [{"value": "293.2 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 293200.0, "url": {"label": "Shinshu_Bulletin02-14.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/17239/files/Shinshu_Bulletin02-14.pdf"}, "version_id": "51c59467-d0ae-4b60-8d71-9448cf6d2322"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u5bfe\u6a19\u6e96\u95a2\u6ce2\u6570\u8abf\u6574\u88c5\u7f6e", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u5bfe\u6a19\u6e96\u95a2\u6ce2\u6570\u8abf\u6574\u88c5\u7f6e"}]}, "item_type_id": "10", "owner": "1", "path": ["1628/1674/1677"], "permalink_uri": "http://hdl.handle.net/10091/4630", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2010-02-12"}, "publish_date": "2010-02-12", "publish_status": "0", "recid": "17239", "relation": {}, "relation_version_is_last": true, "title": ["\u5bfe\u6a19\u6e96\u95a2\u6ce2\u6570\u8abf\u6574\u88c5\u7f6e"], "weko_shared_id": null}
  1. 900 信州大学刊行物
  2. 信州大學紀要
  3. Vol. 02

対標準関波数調整装置

http://hdl.handle.net/10091/4630
ee9291f8-cec5-4777-ac96-525964a17ca0
名前 / ファイル ライセンス アクション
Shinshu_Bulletin02-14.pdf Shinshu_Bulletin02-14.pdf (293.2 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2010-02-12
タイトル
タイトル 対標準関波数調整装置
言語
言語 jpn
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
その他(別言語等)のタイトル
その他のタイトル AN FREQUENCY ADJUSTING SYSTEM FOR STANDARD FREQUENCY
著者 木村, 瑞雄

× 木村, 瑞雄

WEKO 49081

木村, 瑞雄

Search repository
出版者
出版者 信州大学
引用
内容記述タイプ Other
内容記述 信州大學紀要 (2): 149-153(1952)
書誌情報 信州大學紀要

巻 2, p. 149-153, 発行日 1952-07
抄録
内容記述タイプ Abstract
内容記述 The frequency adjusting system described in this paper is newly developed and designd for the purpose of quick and precise adjusting of the frequency deviation of the tuing bar oscilltor for the-standard frequency. Heretofore, the usual method of adjusting of frequency of the tuning bar oscilltors is the one which is worked by hand, for example observing the Lissajous figure produced by cathode-ray tube. This method, however, is unsuitable for the purpose of quick and precise adjustment. The main component elements of the newly developed system are tuning bar filter, amplitude limitter, frequency mixer, frequency control coil which attached close by the tuning bar,etc. If there is any difference in both frequency,the beat frequency is obtained at the output of the mixer. After the beat current is rectified and changed to direct current,this rectfied current flows into control coil. The frequency of the tuning bar changes due to the changing of the control coil,and is automotically synchoronized to the standard frequency, and then the rectfied current becomes certain constant value. Now, by flowing the same value of direct current as that rectfied current into the control coil, by turning ti the another direct electric source, the synchoronization of both frequency is completed quickly and precisely.
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00219843
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 09:44:23.329220
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio