{"_buckets": {"deposit": "00b85896-867a-4444-b60c-f1effd8afe6f"}, "_deposit": {"id": "19349", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "19349"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00019349", "sets": ["882:883"]}, "author_link": ["104593", "104594", "104595", "104596", "104597", "104598", "104599"], "item_1628147817048": {"attribute_name": "\u51fa\u7248\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_6_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "733", "bibliographicPageStart": "727", "bibliographicVolumeNumber": "260", "bibliographic_titles": [{"bibliographic_title": "RADIOLOGY"}]}]}, "item_6_description_20": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "Purpose: To determine whether liver function correlating with indocyanine green (ICG) clearance could be estimated quantitatively from gadoxetate disodium-enhanced magnetic resonance (MR) images. Materials and Methods: This retrospective study was approved by the institutional review board, and the requirement for informed consent was waived. Twenty-three consecutive patients who underwent an ICG clearance test and gadoxetate disodium-enhanced MR imaging with the same parameters as were used for a preoperative examination were chosen. The hepatocellular uptake index (HUI) from liver volume (V(L)) and mean signal intensity of the liver on contrastenhanced T1-weighted images with fat suppression (L(20)) and mean signal intensity of the spleen on contrastenhanced T1-weighted images with fat suppression (S(20)) on 3D gradient-echo T1-weighted images with fat suppression obtained at 20 minutes after gadoxetate disodium (0.025 mmol per kilogram of body weight) administration was determined with the following equation: V(L)[(L(20)/S(20)) 2 1]. The correlation of the plasma disappearance rate of ICG (ICG-PDR) and various factors derived from MR imaging, including HUI, iron and fat deposition in the liver and spleen, and spleen volume (V(S)), were evaluated with stepwise multiple regression analysis. The difference between the ratio of the remnant HUI to the HUI of the total liver (rHUI/HUI) and ratio of the liver remnant V(L) to the total V(L)(rV(L)/V(L)) was evaluated in four patients who had segmental heterogeneity of liver function. Results: HUI and V(S) were the factors significantly correlated with ICG-PDR (R = 0.87). The mean value and its 95% confidence interval were 0.18 and 0.01 to 0.34, respectively, for the following calculation: (rHUI/HUI) 2 (rV(L)/V(L)). Conclusion: The liver function correlating with ICG-PDR can be estimated quantitatively from the signal intensities and the volumes of the liver and spleen on gadoxetate disodium-enhanced MR images, which may improve the estimation of segmental liver function. (C) RSNA, 2011", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7\uff08\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u7a2e\u985e\uff09", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "\u5f15\u7528", "attribute_value_mlt": [{"subitem_description": "RADIOLOGY. 260(3):727-733 (2011)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "\u4fe1\u5dde\u5927\u5b66\u7814\u7a76\u8005\u7dcf\u89a7\u3078\u306e\u30ea\u30f3\u30af", "attribute_value_mlt": [{"subitem_link_text": "Yamada, Akira", "subitem_link_url": "https://soar-rd.shinshu-u.ac.jp/profile/ja.jVnVgUkh.html"}, {"subitem_link_text": "Fujinaga, Yasunari", "subitem_link_url": "https://soar-rd.shinshu-u.ac.jp/profile/ja.WFyeHVkh.html"}]}, "item_6_link_67": {"attribute_name": "WoS", "attribute_value_mlt": [{"subitem_link_text": "Web of Science", "subitem_link_url": "http://gateway.isiknowledge.com/gateway/Gateway.cgi?\u0026GWVersion=2\u0026SrcAuth=ShinshuUniv\u0026SrcApp=ShinshuUniv\u0026DestLinkType=FullRecord\u0026DestApp=WOS\u0026KeyUT=000293944700014"}]}, "item_6_publisher_4": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "RADIOLOGICAL SOC NORTH AMERICA"}]}, "item_6_relation_47": {"attribute_name": "PubMed", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "21712472"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://pubmed.ncbi.nlm.nih.gov/21712472", "subitem_relation_type_select": "PMID"}}]}, "item_6_relation_48": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.1148/radiol.11100586"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1148/radiol.11100586", "subitem_relation_type_select": "DOI"}}]}, "item_6_rights_62": {"attribute_name": "\u6a29\u5229", "attribute_value_mlt": [{"subitem_rights": "\u00a9 RSNA, 2011"}]}, "item_6_select_64": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0033-8419", "subitem_source_identifier_type": "PISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0033-8419", "subitem_source_identifier_type": "PISSN"}]}, "item_6_source_id_40": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00800818", "subitem_source_identifier_type": "NCID"}]}, "item_6_text_70": {"attribute_name": "wosonly keywords", "attribute_value_mlt": [{"subitem_text_value": "GD-EOB-DTPA; BLOOD-FLOW; NONINVASIVE ASSESSMENT; HEPATIC RESECTION; CONTRAST AGENT; FIBROSIS; SCINTIGRAPHY; DYSFUNCTION; VOLUME; RATS"}]}, "item_6_textarea_68": {"attribute_name": "wosonly abstract", "attribute_value_mlt": [{"subitem_textarea_value": "Purpose: To determine whether liver function correlating with indocyanine green (ICG) clearance could be estimated quantitatively from gadoxetate disodium-enhanced magnetic resonance (MR) images. Materials and Methods: This retrospective study was approved by the institutional review board, and the requirement for informed consent was waived. Twenty-three consecutive patients who underwent an ICG clearance test and gadoxetate disodium-enhanced MR imaging with the same parameters as were used for a preoperative examination were chosen. The hepatocellular uptake index (HUI) from liver volume (V(L)) and mean signal intensity of the liver on contrastenhanced T1-weighted images with fat suppression (L(20)) and mean signal intensity of the spleen on contrastenhanced T1-weighted images with fat suppression (S(20)) on 3D gradient-echo T1-weighted images with fat suppression obtained at 20 minutes after gadoxetate disodium (0.025 mmol per kilogram of body weight) administration was determined with the following equation: V(L)[(L(20)/S(20)) 2 1]. The correlation of the plasma disappearance rate of ICG (ICG-PDR) and various factors derived from MR imaging, including HUI, iron and fat deposition in the liver and spleen, and spleen volume (V(S)), were evaluated with stepwise multiple regression analysis. The difference between the ratio of the remnant HUI to the HUI of the total liver (rHUI/HUI) and ratio of the liver remnant V(L) to the total V(L)(rV(L)/V(L)) was evaluated in four patients who had segmental heterogeneity of liver function. Results: HUI and V(S) were the factors significantly correlated with ICG-PDR (R = 0.87). The mean value and its 95% confidence interval were 0.18 and 0.01 to 0.34, respectively, for the following calculation: (rHUI/HUI) 2 (rV(L)/V(L)). Conclusion: The liver function correlating with ICG-PDR can be estimated quantitatively from the signal intensities and the volumes of the liver and spleen on gadoxetate disodium-enhanced MR images, which may improve the estimation of segmental liver function. (C) RSNA, 2011"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Yamada, Akira", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "104593", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hara, Takeshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "104594", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Li, Feng", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "104595", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujinaga, Yasunari", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "104596", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ueda, Kazuhiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "104597", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kadoya, Masumi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "104598", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Doi, Kunio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "104599", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-12-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Quantitative_evaluation_of_liver_function_by_use_of_gadoxetate_disodium.pdf", "filesize": [{"value": "520.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "\u00a9 RSNA, 2011", "licensetype": "license_note", "mimetype": "application/pdf", "size": 520900.0, "url": {"label": "Quantitative_evaluation_of_liver_function_by_use_of_gadoxetate_disodium.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/19349/files/Quantitative_evaluation_of_liver_function_by_use_of_gadoxetate_disodium.pdf"}, "version_id": "a775aabf-9fca-4de2-a825-26bec92260f3"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Quantitative Evaluation of Liver Function with Use of Gadoxetate Disodium-enhanced MR Imaging", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "Quantitative Evaluation of Liver Function with Use of Gadoxetate Disodium-enhanced MR Imaging", "subitem_title_language": "en"}]}, "item_type_id": "6", "owner": "1", "path": ["882/883"], "permalink_uri": "http://hdl.handle.net/10091/00020110", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2017-12-25"}, "publish_date": "2017-12-25", "publish_status": "0", "recid": "19349", "relation": {}, "relation_version_is_last": true, "title": ["Quantitative Evaluation of Liver Function with Use of Gadoxetate Disodium-enhanced MR Imaging"], "weko_shared_id": -1}
  1. 055 医学部附属病院
  2. 0551 学術論文

Quantitative Evaluation of Liver Function with Use of Gadoxetate Disodium-enhanced MR Imaging

http://hdl.handle.net/10091/00020110
e932f5fe-374b-42f4-b76b-7be325e2d013
名前 / ファイル ライセンス アクション
Quantitative_evaluation_of_liver_function_by_use_of_gadoxetate_disodium.pdf Quantitative_evaluation_of_liver_function_by_use_of_gadoxetate_disodium.pdf (520.9 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-12-25
タイトル
言語 en
タイトル Quantitative Evaluation of Liver Function with Use of Gadoxetate Disodium-enhanced MR Imaging
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
著者 Yamada, Akira

× Yamada, Akira

WEKO 104593

en Yamada, Akira

Search repository
Hara, Takeshi

× Hara, Takeshi

WEKO 104594

en Hara, Takeshi

Search repository
Li, Feng

× Li, Feng

WEKO 104595

en Li, Feng

Search repository
Fujinaga, Yasunari

× Fujinaga, Yasunari

WEKO 104596

en Fujinaga, Yasunari

Search repository
Ueda, Kazuhiko

× Ueda, Kazuhiko

WEKO 104597

en Ueda, Kazuhiko

Search repository
Kadoya, Masumi

× Kadoya, Masumi

WEKO 104598

en Kadoya, Masumi

Search repository
Doi, Kunio

× Doi, Kunio

WEKO 104599

en Doi, Kunio

Search repository
信州大学研究者総覧へのリンク
氏名 Yamada, Akira
URL https://soar-rd.shinshu-u.ac.jp/profile/ja.jVnVgUkh.html
信州大学研究者総覧へのリンク
氏名 Fujinaga, Yasunari
URL https://soar-rd.shinshu-u.ac.jp/profile/ja.WFyeHVkh.html
出版者
出版者 RADIOLOGICAL SOC NORTH AMERICA
引用
内容記述タイプ Other
内容記述 RADIOLOGY. 260(3):727-733 (2011)
書誌情報 RADIOLOGY

巻 260, 号 3, p. 727-733, 発行日 2011-09
抄録
内容記述タイプ Abstract
内容記述 Purpose: To determine whether liver function correlating with indocyanine green (ICG) clearance could be estimated quantitatively from gadoxetate disodium-enhanced magnetic resonance (MR) images. Materials and Methods: This retrospective study was approved by the institutional review board, and the requirement for informed consent was waived. Twenty-three consecutive patients who underwent an ICG clearance test and gadoxetate disodium-enhanced MR imaging with the same parameters as were used for a preoperative examination were chosen. The hepatocellular uptake index (HUI) from liver volume (V(L)) and mean signal intensity of the liver on contrastenhanced T1-weighted images with fat suppression (L(20)) and mean signal intensity of the spleen on contrastenhanced T1-weighted images with fat suppression (S(20)) on 3D gradient-echo T1-weighted images with fat suppression obtained at 20 minutes after gadoxetate disodium (0.025 mmol per kilogram of body weight) administration was determined with the following equation: V(L)[(L(20)/S(20)) 2 1]. The correlation of the plasma disappearance rate of ICG (ICG-PDR) and various factors derived from MR imaging, including HUI, iron and fat deposition in the liver and spleen, and spleen volume (V(S)), were evaluated with stepwise multiple regression analysis. The difference between the ratio of the remnant HUI to the HUI of the total liver (rHUI/HUI) and ratio of the liver remnant V(L) to the total V(L)(rV(L)/V(L)) was evaluated in four patients who had segmental heterogeneity of liver function. Results: HUI and V(S) were the factors significantly correlated with ICG-PDR (R = 0.87). The mean value and its 95% confidence interval were 0.18 and 0.01 to 0.34, respectively, for the following calculation: (rHUI/HUI) 2 (rV(L)/V(L)). Conclusion: The liver function correlating with ICG-PDR can be estimated quantitatively from the signal intensities and the volumes of the liver and spleen on gadoxetate disodium-enhanced MR images, which may improve the estimation of segmental liver function. (C) RSNA, 2011
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
ISSN
収録物識別子タイプ PISSN
収録物識別子 0033-8419
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA00800818
PubMed
関連識別子
識別子タイプ PMID
関連識別子 https://pubmed.ncbi.nlm.nih.gov/21712472
関連名称
関連名称 21712472
DOI
関連識別子
識別子タイプ DOI
関連識別子 https://doi.org/10.1148/radiol.11100586
関連名称
関連名称 10.1148/radiol.11100586
権利
権利情報 © RSNA, 2011
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
WoS
表示名 Web of Science
URL http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000293944700014
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 08:18:34.542983
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio