{"_buckets": {"deposit": "0998aa42-1f4b-408a-9ed2-e499da7ef71a"}, "_deposit": {"id": "19576", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "19576"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00019576", "sets": ["1222"]}, "author_link": ["105093", "105094", "105095", "105096", "105097"], "item_1628147817048": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_6_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "7", "bibliographicPageEnd": "1243", "bibliographicPageStart": "1238", "bibliographicVolumeNumber": "54", "bibliographic_titles": [{"bibliographic_title": "JOURNAL OF CHROMATOGRAPHIC SCIENCE"}]}]}, "item_6_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A new type of clay column particles was prepared, in which a hectorite layer (similar to 0.1 mu m thickness) covered uniformly the surface of amorphous silica particles with an average radius of 5 mu m (ref. Okada et al., The Journal of Physical Chemistry C, 116, 21864-21869 (2012)). The hectorite layer was fully ion-exchanged with Delta-[Ru(phen)(3)](2+) (phen = 1,10-phenanthroline) ions by being immersed in a methanol solution of Delta-[Ru(phen)(3)](ClO4)(2) (1 mM). The modified silica gel particles thus prepared were packed into a stainless steel tube (4 mm (i.d.) x 25 cm) as a high-performance liquid chromatography column. Optical resolution was achieved when the racemic mixtures of several metal complexes or organic molecules were eluted with methanol. In the case of tris(acetylacetonato) ruthenium(III) ([Ru(acac)(3)]), for example, the Lambda- and Delta-enantiomers gave an elution volume of 2.6 and 3.0 mL, respectively, with the separation factor of 1.2. The total elution volume (5 mL) was nearly one-tenth for the previously reported column of the same size (RU-1 (Shiseido Co., Ltd.)) packed with the spray-dried particles of synthetic hectorite (average radius 5 mu m) ion-exchanged by the same Ru(II) complexes.", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "JOURNAL OF CHROMATOGRAPHIC SCIENCE. 54(7): 1238-1243 (2016)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "信州大学研究者総覧へのリンク", "attribute_value_mlt": [{"subitem_link_text": "Okada, Tomohiko", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.WpDFbpkh.html"}]}, "item_6_link_67": {"attribute_name": "WoS", "attribute_value_mlt": [{"subitem_link_text": "Web of Science", "subitem_link_url": "http://gateway.isiknowledge.com/gateway/Gateway.cgi?\u0026GWVersion=2\u0026SrcAuth=ShinshuUniv\u0026SrcApp=ShinshuUniv\u0026DestLinkType=FullRecord\u0026DestApp=WOS\u0026KeyUT=000389138700023"}]}, "item_6_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "OXFORD UNIV PRESS INC"}]}, "item_6_relation_48": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.1093/chromsci/bmw058"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1093/chromsci/bmw058", "subitem_relation_type_select": "DOI"}}]}, "item_6_rights_62": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "This is a pre-copyedited, author-produced version of an article accepted for publication in JOURNAL OF CHROMATOGRAPHIC SCIENCE following peer review. The version of record JOURNAL OF CHROMATOGRAPHIC SCIENCE. 54(7): 1238-1243 (2016) is available online at: https://doi.org/10.1093/chromsci/bmw058"}]}, "item_6_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0021-9665", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0021-9665", "subitem_source_identifier_type": "ISSN"}]}, "item_6_text_70": {"attribute_name": "wosonly keywords", "attribute_value_mlt": [{"subitem_text_value": "PERFORMANCE LIQUID-CHROMATOGRAPHY@@@CHIRAL STATIONARY-PHASE@@@LAYER CHARGE-DENSITY@@@OPTICAL RESOLUTION@@@CLAY COLUMN@@@METAL-COMPLEXES@@@ENANTIOSEPARATION@@@ENANTIOMERS@@@ADSORPTION@@@RU(III)"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Okada, Tomohiko"}], "nameIdentifiers": [{"nameIdentifier": "105093", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kumasaki, Aisaku"}], "nameIdentifiers": [{"nameIdentifier": "105094", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shimizu, Kei"}], "nameIdentifiers": [{"nameIdentifier": "105095", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamagishi, Akihiko"}], "nameIdentifiers": [{"nameIdentifier": "105096", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sato, Hisako"}], "nameIdentifiers": [{"nameIdentifier": "105097", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-03-09"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Application_of_Hectorite-Coated_Silica_Gel_Particles_as_a_Packing_Material_for_Chromatographic_Resolution.pdf", "filesize": [{"value": "454.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "This is a pre-copyedited, author-produced version of an article accepted for publication in JOURNAL OF CHROMATOGRAPHIC SCIENCE following peer review. The version of record JOURNAL OF CHROMATOGRAPHIC SCIENCE. 54(7): 1238-1243 (2016) is available online at: https://doi.org/10.1093/chromsci/bmw058", "licensetype": "license_note", "mimetype": "application/pdf", "size": 454800.0, "url": {"label": "Application_of_Hectorite-Coated_Silica_Gel_Particles_as_a_Packing_Material_for_Chromatographic_Resolution.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/19576/files/Application_of_Hectorite-Coated_Silica_Gel_Particles_as_a_Packing_Material_for_Chromatographic_Resolution.pdf"}, "version_id": "774d3ee4-8997-4e11-9939-98073dc36143"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Application of Hectorite-Coated Silica Gel Particles as a Packing Material for Chromatographic Resolution", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Application of Hectorite-Coated Silica Gel Particles as a Packing Material for Chromatographic Resolution", "subitem_title_language": "en"}]}, "item_type_id": "6", "owner": "1", "path": ["1222"], "permalink_uri": "http://hdl.handle.net/10091/00020337", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2018-03-09"}, "publish_date": "2018-03-09", "publish_status": "0", "recid": "19576", "relation": {}, "relation_version_is_last": true, "title": ["Application of Hectorite-Coated Silica Gel Particles as a Packing Material for Chromatographic Resolution"], "weko_shared_id": -1}
Application of Hectorite-Coated Silica Gel Particles as a Packing Material for Chromatographic Resolution
http://hdl.handle.net/10091/00020337
http://hdl.handle.net/10091/00020337ea31866c-53e2-484e-ac22-f99c5f35e1f6
名前 / ファイル | ライセンス | アクション |
---|---|---|
Application_of_Hectorite-Coated_Silica_Gel_Particles_as_a_Packing_Material_for_Chromatographic_Resolution.pdf (454.8 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-03-09 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Application of Hectorite-Coated Silica Gel Particles as a Packing Material for Chromatographic Resolution | |||||
言語 | ||||||
言語 | eng | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1093/chromsci/bmw058 | |||||
関連名称 | 10.1093/chromsci/bmw058 | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
Okada, Tomohiko
× Okada, Tomohiko× Kumasaki, Aisaku× Shimizu, Kei× Yamagishi, Akihiko× Sato, Hisako |
|||||
信州大学研究者総覧へのリンク | ||||||
氏名 | Okada, Tomohiko | |||||
URL | http://soar-rd.shinshu-u.ac.jp/profile/ja.WpDFbpkh.html | |||||
出版者 | ||||||
出版者 | OXFORD UNIV PRESS INC | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | JOURNAL OF CHROMATOGRAPHIC SCIENCE. 54(7): 1238-1243 (2016) | |||||
書誌情報 |
JOURNAL OF CHROMATOGRAPHIC SCIENCE 巻 54, 号 7, p. 1238-1243, 発行日 2016 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A new type of clay column particles was prepared, in which a hectorite layer (similar to 0.1 mu m thickness) covered uniformly the surface of amorphous silica particles with an average radius of 5 mu m (ref. Okada et al., The Journal of Physical Chemistry C, 116, 21864-21869 (2012)). The hectorite layer was fully ion-exchanged with Delta-[Ru(phen)(3)](2+) (phen = 1,10-phenanthroline) ions by being immersed in a methanol solution of Delta-[Ru(phen)(3)](ClO4)(2) (1 mM). The modified silica gel particles thus prepared were packed into a stainless steel tube (4 mm (i.d.) x 25 cm) as a high-performance liquid chromatography column. Optical resolution was achieved when the racemic mixtures of several metal complexes or organic molecules were eluted with methanol. In the case of tris(acetylacetonato) ruthenium(III) ([Ru(acac)(3)]), for example, the Lambda- and Delta-enantiomers gave an elution volume of 2.6 and 3.0 mL, respectively, with the separation factor of 1.2. The total elution volume (5 mL) was nearly one-tenth for the previously reported column of the same size (RU-1 (Shiseido Co., Ltd.)) packed with the spray-dried particles of synthetic hectorite (average radius 5 mu m) ion-exchanged by the same Ru(II) complexes. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0021-9665 | |||||
権利 | ||||||
権利情報 | This is a pre-copyedited, author-produced version of an article accepted for publication in JOURNAL OF CHROMATOGRAPHIC SCIENCE following peer review. The version of record JOURNAL OF CHROMATOGRAPHIC SCIENCE. 54(7): 1238-1243 (2016) is available online at: https://doi.org/10.1093/chromsci/bmw058 | |||||