Influence of Individual Differences on the Calculation Method for FBG-Type Blood Pressure Sensors

http://hdl.handle.net/10091/00021607
http://hdl.handle.net/10091/00021607
f7395662-af55-4028-8e3b-1a6cf9ac5a51
名前 / ファイル ライセンス アクション
15K01281_06.pdf 15K01281_06.pdf (3.0 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-09-09
タイトル
タイトル Influence of Individual Differences on the Calculation Method for FBG-Type Blood Pressure Sensors
言語
言語 eng
DOI
関連識別子 https://doi.org/10.3390/s17010048
関連名称 10.3390/s17010048
キーワード
主題 FBG, blood pressure, acceleration pulse wave, individual difference, Partial Least Squares Regression
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
著者 Koyama, Shouhei

× Koyama, Shouhei

en Koyama, Shouhei

Search repository
Ishizawa, Hiroaki

× Ishizawa, Hiroaki

en Ishizawa, Hiroaki

Search repository
Fujimoto, Keisaku

× Fujimoto, Keisaku

en Fujimoto, Keisaku

Search repository
Chino, Shun

× Chino, Shun

en Chino, Shun

Search repository
Kobayashi, Yuka

× Kobayashi, Yuka

en Kobayashi, Yuka

Search repository
信州大学研究者総覧へのリンク
氏名 Koyama, Shouhei
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.uVDFbakF.html
信州大学研究者総覧へのリンク
氏名 Ishizawa, Hiroaki
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.yNnhjFkV.html
信州大学研究者総覧へのリンク
氏名 Fujimoto, Keisaku
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.yFfaHFkh.html
出版者
出版者 MDPI AG
引用
内容記述 SENSORS.17(1):48(2016)
書誌情報 SENSORS

巻 17, 号 1, p. 48, 発行日 2016-12-28
抄録
内容記述 In this paper, we propose a blood pressure calculation and associated measurement method that by using a fiber Bragg grating (FBG) sensor. There are several points at which the pulse can be measured on the surface of the human body, and when a FBG sensor located at any of these points, the pulse wave signal can be measured. The measured waveform is similar to the acceleration pulse wave. The pulse wave signal changes depending on several factors, including whether or not the individual is healthy and/or elderly. The measured pulse wave signal can be used to calculate the blood pressure using a calibration curve, which is constructed by a partial least squares (PLS) regression analysis using a reference blood pressure and the pulse wave signal. In this paper, we focus on the influence of individual differences from calculated blood pressure based on each calibration curve. In our study, the calculated blood pressure from both the individual and overall calibration curves were compared, and our results show that the calculated blood pressure based on the overall calibration curve had a lower measurement accuracy than that based on an individual calibration curve. We also found that the influence of the individual differences on the calculated blood pressure when using the FBG sensor method were very low. Therefore, the FBG sensor method that we developed for measuring the blood pressure was found to be suitable for use by many people.
資源タイプ(コンテンツの種類)
ISSN
収録物識別子タイプ EISSN
収録物識別子 1424-8220
PubMed
識別子タイプ PMID
関連識別子 https://www.ncbi.nlm.nih.gov/pubmed/28036015
関連名称 28036015
権利
権利情報 © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
WoS
URL http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000393021000048
戻る
0
views
See details
Views