{"_buckets": {"deposit": "ede2b977-fd28-4b21-a9ef-51ed0d335c38"}, "_deposit": {"id": "21737", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "21737"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00021737", "sets": ["1222"]}, "author_link": ["110195", "110196"], "item_1628147817048": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_6_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019-07-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "8", "bibliographicPageStart": "084602", "bibliographicVolumeNumber": "88", "bibliographic_titles": [{"bibliographic_title": "JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN"}]}]}, "item_6_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "AC electro-osmotic (ACEO) pumps play an important role in a wide diversity of microfiuidic applications. To produce high flow velocities, an effective breaking of symmetry is prerequisite. Here, we introduced a ratchet-structured electrode for achieving high flow velocities and developed a ratchet ACED pump containing both ratchet and plane electrodes. The performance of our new ACED pump is evaluated experimentally. At an ac voltage of 30 V at 10kHz, a maximum net flow velocity of 1.1 mm/s is measured along the inclined direction of the ratchet teeth. Furthermore, we also directly observed the flow fields due to the slip velocity of ACEO, which provide a physical insight on the ratchet-type ACED pumps.", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN.88(8):084602(2019)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "信州大学研究者総覧へのリンク", "attribute_value_mlt": [{"subitem_link_text": "Sugioka, Hideyuki", "subitem_link_url": "https://soar-rd.shinshu-u.ac.jp/profile/ja.gpkmbUkh.html"}]}, "item_6_link_67": {"attribute_name": "WoS", "attribute_value_mlt": [{"subitem_link_text": "Web of Science", "subitem_link_url": "http://gateway.isiknowledge.com/gateway/Gateway.cgi?\u0026GWVersion=2\u0026SrcAuth=ShinshuUniv\u0026SrcApp=ShinshuUniv\u0026DestLinkType=FullRecord\u0026DestApp=WOS\u0026KeyUT=000477716800022"}]}, "item_6_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "PHYSICAL SOC JAPAN"}]}, "item_6_relation_48": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.7566/JPSJ.88.084602"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.7566/JPSJ.88.084602", "subitem_relation_type_select": "DOI"}}]}, "item_6_rights_62": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "©2019 The Physical Society of Japan"}]}, "item_6_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0031-9015", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0031-9015", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00704814", "subitem_source_identifier_type": "NCID"}]}, "item_6_text_69": {"attribute_name": "wosonly authkey", "attribute_value_mlt": [{"subitem_text_value": "MICROPUMPS"}]}, "item_6_text_70": {"attribute_name": "wosonly keywords", "attribute_value_mlt": [{"subitem_text_value": "AC electro-osmotic (ACEO) pumps play an important role in a wide diversity of microfiuidic applications. To produce high flow velocities, an effective breaking of symmetry is prerequisite. Here, we introduced a ratchet-structured electrode for achieving high flow velocities and developed a ratchet ACED pump containing both ratchet and plane electrodes. The performance of our new ACED pump is evaluated experimentally. At an ac voltage of 30 V at 10kHz, a maximum net flow velocity of 1.1 mm/s is measured along the inclined direction of the ratchet teeth. Furthermore, we also directly observed the flow fields due to the slip velocity of ACEO, which provide a physical insight on the ratchet-type ACED pumps."}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sugioka, Hideyuki"}], "nameIdentifiers": [{"nameIdentifier": "110195", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Segawa, Satoru"}], "nameIdentifiers": [{"nameIdentifier": "110196", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2021-02-08"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "JPSJ88_084602.pdf", "filesize": [{"value": "4.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "©2019 The Physical Society of Japan", "licensetype": "license_note", "mimetype": "application/pdf", "size": 4000000.0, "url": {"label": "JPSJ88_084602.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/21737/files/JPSJ88_084602.pdf"}, "version_id": "0aab9ee8-8dc6-4ef2-b6ef-8e41f30e0c96"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Effective Symmetry Breaking of Flow in AC Electro-Osmotic Pump Using a Ratchet Structure", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Effective Symmetry Breaking of Flow in AC Electro-Osmotic Pump Using a Ratchet Structure", "subitem_title_language": "en"}]}, "item_type_id": "6", "owner": "1", "path": ["1222"], "permalink_uri": "http://hdl.handle.net/10091/00022494", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2021-02-08"}, "publish_date": "2021-02-08", "publish_status": "0", "recid": "21737", "relation": {}, "relation_version_is_last": true, "title": ["Effective Symmetry Breaking of Flow in AC Electro-Osmotic Pump Using a Ratchet Structure"], "weko_shared_id": -1}
Effective Symmetry Breaking of Flow in AC Electro-Osmotic Pump Using a Ratchet Structure
http://hdl.handle.net/10091/00022494
http://hdl.handle.net/10091/00022494737320ff-e300-473b-b6bc-92e65ea0942d
名前 / ファイル | ライセンス | アクション |
---|---|---|
JPSJ88_084602.pdf (4.0 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-02-08 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Effective Symmetry Breaking of Flow in AC Electro-Osmotic Pump Using a Ratchet Structure | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
Sugioka, Hideyuki
× Sugioka, Hideyuki× Segawa, Satoru |
|||||
信州大学研究者総覧へのリンク | ||||||
氏名 | Sugioka, Hideyuki | |||||
URL | https://soar-rd.shinshu-u.ac.jp/profile/ja.gpkmbUkh.html | |||||
出版者 | ||||||
出版者 | PHYSICAL SOC JAPAN | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN.88(8):084602(2019) | |||||
書誌情報 |
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN 巻 88, 号 8, p. 084602, 発行日 2019-07-05 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | AC electro-osmotic (ACEO) pumps play an important role in a wide diversity of microfiuidic applications. To produce high flow velocities, an effective breaking of symmetry is prerequisite. Here, we introduced a ratchet-structured electrode for achieving high flow velocities and developed a ratchet ACED pump containing both ratchet and plane electrodes. The performance of our new ACED pump is evaluated experimentally. At an ac voltage of 30 V at 10kHz, a maximum net flow velocity of 1.1 mm/s is measured along the inclined direction of the ratchet teeth. Furthermore, we also directly observed the flow fields due to the slip velocity of ACEO, which provide a physical insight on the ratchet-type ACED pumps. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0031-9015 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00704814 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.7566/JPSJ.88.084602 | |||||
関連名称 | 10.7566/JPSJ.88.084602 | |||||
権利 | ||||||
権利情報 | ©2019 The Physical Society of Japan | |||||
出版タイプ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa | |||||
WoS | ||||||
表示名 | Web of Science | |||||
URL | http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000477716800022 |