{"_buckets": {"deposit": "dfb29373-8bed-4b52-b966-5bb7e9f6a2d7"}, "_deposit": {"id": "3701", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "3701"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00003701", "sets": ["462"]}, "author_link": ["6461", "6462", "6463", "6464", "6465"], "item_1628147817048": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_6_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "11", "bibliographicPageEnd": "2081", "bibliographicPageStart": "2073", "bibliographicVolumeNumber": "102", "bibliographic_titles": [{"bibliographic_title": "CANCER SCIENCE"}]}]}, "item_6_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The contrast-enhanced ultrasound (CEUS)-guided method in combination with Sonazoid has not been clinically or experimentally evaluated with regard to its use for identifying sentinel lymph node (SLN) in the stomach. Therefore, we attempted to evaluate the usefulness of the CEUS-guided method with Sonazoid for imaging of the lymphatic channels and SLN of the stomach in a porcine model by comparing it with the conventional Evans blue dye-guided method. Twenty-eight 2 to 3-month-old swine weighing 17-30 kg were used in this experiment. Anesthesia was maintained with 2.0-3.0% isoflurane/O(2) inhalation. Sonazoid was injected into the intra-and sub-mucosal layers of the stomach. The intragastric or transcutaneous CEUS-guided method was used to identify the lymphatic channels and SLN of the stomach. Contrast imaging using the CEUS-guided method with Sonazoid enabled us to produce clear images of the afferent lymph vessel and SLN of the stomach until 2 h after the injection of Sonazoid. In addition, intranodal flow of the microbubble agent could be clearly identified using tissue linear harmonic images of the SLN. The SLN detection rate was not significantly different between the CEUS- and dye-guided methods. However, the Evans blue dye flowed out quickly (similar to 15 min after the injection) through the true SLN into the next LN of stomach. In conclusion, the use of the CEUS-guided method with Sonazoid might be the most useful clinical procedure for producing real-time images of the SLN of the stomach, and the linear harmonic images are also useful for evaluating intranodal structure within the SLN. (Cancer Sci 2011; 102: 2073-2081)", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "CANCER SCIENCE. 102(11):2073-2081 (2011)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "信州大学研究者総覧へのリンク", "attribute_value_mlt": [{"subitem_link_text": "Kawai, Yoshiko", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.uCDFuakh.html"}, {"subitem_link_text": "Ohhashi, Toshio", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.HFApOFkh.html"}]}, "item_6_link_67": {"attribute_name": "WoS", "attribute_value_mlt": [{"subitem_link_text": "Web of Science", "subitem_link_url": "http://gateway.isiknowledge.com/gateway/Gateway.cgi?\u0026GWVersion=2\u0026SrcAuth=ShinshuUniv\u0026SrcApp=ShinshuUniv\u0026DestLinkType=FullRecord\u0026DestApp=WOS\u0026KeyUT=000296910100020"}]}, "item_6_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "WILEY-BLACKWELL"}]}, "item_6_relation_47": {"attribute_name": "PubMed", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "21797945"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://pubmed.ncbi.nlm.nih.gov/21797945", "subitem_relation_type_select": "PMID"}}]}, "item_6_relation_48": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.1111/j.1349-7006.2011.02048.x"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1111/j.1349-7006.2011.02048.x", "subitem_relation_type_select": "DOI"}}]}, "item_6_rights_62": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright© 2011 Japanese Cancer Association."}]}, "item_6_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1347-9032", "subitem_source_identifier_type": "PISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1347-9032", "subitem_source_identifier_type": "PISSN"}]}, "item_6_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11808050", "subitem_source_identifier_type": "NCID"}]}, "item_6_text_70": {"attribute_name": "wosonly keywords", "attribute_value_mlt": [{"subitem_text_value": "GASTRIC-CANCER SURGERY; GASTROINTESTINAL CANCER; TECHNICAL DETAILS; BREAST-CANCER; TUMOR-CELLS; BIOPSY; CARCINOMA; MELANOMA; ECHOCARDIOGRAPHY; METASTASIS"}]}, "item_6_textarea_68": {"attribute_name": "wosonly abstract", "attribute_value_mlt": [{"subitem_textarea_value": "The contrast-enhanced ultrasound (CEUS)-guided method in combination with Sonazoid has not been clinically or experimentally evaluated with regard to its use for identifying sentinel lymph node (SLN) in the stomach. Therefore, we attempted to evaluate the usefulness of the CEUS-guided method with Sonazoid for imaging of the lymphatic channels and SLN of the stomach in a porcine model by comparing it with the conventional Evans blue dye-guided method. Twenty-eight 2 to 3-month-old swine weighing 17-30 kg were used in this experiment. Anesthesia was maintained with 2.0-3.0% isoflurane/O(2) inhalation. Sonazoid was injected into the intra-and sub-mucosal layers of the stomach. The intragastric or transcutaneous CEUS-guided method was used to identify the lymphatic channels and SLN of the stomach. Contrast imaging using the CEUS-guided method with Sonazoid enabled us to produce clear images of the afferent lymph vessel and SLN of the stomach until 2 h after the injection of Sonazoid. In addition, intranodal flow of the microbubble agent could be clearly identified using tissue linear harmonic images of the SLN. The SLN detection rate was not significantly different between the CEUS- and dye-guided methods. However, the Evans blue dye flowed out quickly (similar to 15 min after the injection) through the true SLN into the next LN of stomach. In conclusion, the use of the CEUS-guided method with Sonazoid might be the most useful clinical procedure for producing real-time images of the SLN of the stomach, and the linear harmonic images are also useful for evaluating intranodal structure within the SLN. (Cancer Sci 2011; 102: 2073-2081)"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Kawai,  Yoshiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6461", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ajima,  Kumiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6462", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nagai,  Takashi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6463", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kaidoh,  Maki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6464", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ohhashi,  Toshio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6465", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorNameLang": "en"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Real-time_imaging_lymphatic_channels.pdf", "filesize": [{"value": "2.5 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 2500000.0, "url": {"label": "Real-time_imaging_lymphatic_channels.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/3701/files/Real-time_imaging_lymphatic_channels.pdf"}, "version_id": "60096087-4c68-429c-811c-d0a87f3cc80c"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Real-time imaging of the lymphatic channels and sentinel lymph nodes of the stomach using contrast-enhanced ultrasonography with Sonazoid in a porcine model", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Real-time imaging of the lymphatic channels and sentinel lymph nodes of the stomach using contrast-enhanced ultrasonography with Sonazoid in a porcine model", "subitem_title_language": "en"}]}, "item_type_id": "6", "owner": "1", "path": ["462"], "permalink_uri": "http://hdl.handle.net/10091/17691", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2014-07-09"}, "publish_date": "2014-07-09", "publish_status": "0", "recid": "3701", "relation": {}, "relation_version_is_last": true, "title": ["Real-time imaging of the lymphatic channels and sentinel lymph nodes of the stomach using contrast-enhanced ultrasonography with Sonazoid in a porcine model"], "weko_shared_id": -1}
  1. 050 医学部, 大学院医学系研究科
  2. 0501 学術論文

Real-time imaging of the lymphatic channels and sentinel lymph nodes of the stomach using contrast-enhanced ultrasonography with Sonazoid in a porcine model

http://hdl.handle.net/10091/17691
http://hdl.handle.net/10091/17691
aa1371fc-4703-4cca-bd2c-5ac120cd2d14
名前 / ファイル ライセンス アクション
Real-time_imaging_lymphatic_channels.pdf Real-time_imaging_lymphatic_channels.pdf (2.5 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-07-09
タイトル
言語 en
タイトル Real-time imaging of the lymphatic channels and sentinel lymph nodes of the stomach using contrast-enhanced ultrasonography with Sonazoid in a porcine model
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
著者 Kawai, Yoshiko

× Kawai, Yoshiko

WEKO 6461

en Kawai, Yoshiko

Search repository
Ajima, Kumiko

× Ajima, Kumiko

WEKO 6462

en Ajima, Kumiko

Search repository
Nagai, Takashi

× Nagai, Takashi

WEKO 6463

en Nagai, Takashi

Search repository
Kaidoh, Maki

× Kaidoh, Maki

WEKO 6464

en Kaidoh, Maki

Search repository
Ohhashi, Toshio

× Ohhashi, Toshio

WEKO 6465

en Ohhashi, Toshio

Search repository

×

en
Search repository
信州大学研究者総覧へのリンク
氏名 Kawai, Yoshiko
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.uCDFuakh.html
信州大学研究者総覧へのリンク
氏名 Ohhashi, Toshio
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.HFApOFkh.html
出版者
出版者 WILEY-BLACKWELL
引用
内容記述タイプ Other
内容記述 CANCER SCIENCE. 102(11):2073-2081 (2011)
書誌情報 CANCER SCIENCE

巻 102, 号 11, p. 2073-2081, 発行日 2011-11
抄録
内容記述タイプ Abstract
内容記述 The contrast-enhanced ultrasound (CEUS)-guided method in combination with Sonazoid has not been clinically or experimentally evaluated with regard to its use for identifying sentinel lymph node (SLN) in the stomach. Therefore, we attempted to evaluate the usefulness of the CEUS-guided method with Sonazoid for imaging of the lymphatic channels and SLN of the stomach in a porcine model by comparing it with the conventional Evans blue dye-guided method. Twenty-eight 2 to 3-month-old swine weighing 17-30 kg were used in this experiment. Anesthesia was maintained with 2.0-3.0% isoflurane/O(2) inhalation. Sonazoid was injected into the intra-and sub-mucosal layers of the stomach. The intragastric or transcutaneous CEUS-guided method was used to identify the lymphatic channels and SLN of the stomach. Contrast imaging using the CEUS-guided method with Sonazoid enabled us to produce clear images of the afferent lymph vessel and SLN of the stomach until 2 h after the injection of Sonazoid. In addition, intranodal flow of the microbubble agent could be clearly identified using tissue linear harmonic images of the SLN. The SLN detection rate was not significantly different between the CEUS- and dye-guided methods. However, the Evans blue dye flowed out quickly (similar to 15 min after the injection) through the true SLN into the next LN of stomach. In conclusion, the use of the CEUS-guided method with Sonazoid might be the most useful clinical procedure for producing real-time images of the SLN of the stomach, and the linear harmonic images are also useful for evaluating intranodal structure within the SLN. (Cancer Sci 2011; 102: 2073-2081)
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
ISSN
収録物識別子タイプ PISSN
収録物識別子 1347-9032
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA11808050
PubMed
識別子タイプ PMID
関連識別子 https://pubmed.ncbi.nlm.nih.gov/21797945
関連名称 21797945
DOI
識別子タイプ DOI
関連識別子 https://doi.org/10.1111/j.1349-7006.2011.02048.x
関連名称 10.1111/j.1349-7006.2011.02048.x
権利
権利情報 Copyright© 2011 Japanese Cancer Association.
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
WoS
表示名 Web of Science
URL http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000296910100020
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 07:57:46.436558
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3