Item type |
学術雑誌論文 / Journal Article(1) |
公開日 |
2013-04-01 |
タイトル |
|
|
タイトル |
Scissoring of cerebral aneurysm clips: mechanical endurance of clip twisting |
言語 |
|
|
言語 |
eng |
DOI |
|
|
|
関連識別子 |
https://doi.org/10.1007/s10143-011-0347-0 |
|
|
関連名称 |
10.1007/s10143-011-0347-0 |
キーワード |
|
|
主題 |
Aneurysm clip, Subarachnoid hemorrhage, Scissoring, Surgery |
資源タイプ |
|
|
資源 |
http://purl.org/coar/resource_type/c_6501 |
|
タイプ |
journal article |
著者 |
Horiuchi, Tetsuyoshi
Hongo, Kazuhiro
Shibuya, Masato
|
信州大学研究者総覧へのリンク |
|
|
氏名 |
Horiuchi, Tetsuyoshi |
|
URL |
http://soar-rd.shinshu-u.ac.jp/profile/ja.uUTpHhkh.html |
信州大学研究者総覧へのリンク |
|
|
氏名 |
Hongo, Kazuhiro |
|
URL |
http://soar-rd.shinshu-u.ac.jp/profile/ja.jecFHCkh.html |
出版者 |
|
|
出版者 |
SPRINGER |
引用 |
|
|
内容記述 |
NEUROSURGICAL REVIEW. 35(2):219-224 (2012) |
書誌情報 |
NEUROSURGICAL REVIEW
巻 35,
号 2,
p. 219-224,
発行日 2012-04
|
抄録 |
|
|
内容記述 |
Although the cerebral aneurysm clip "scissoring" phenomenon is known to occur due to twisting of the aneurysm clip blades during surgery, there have been few previous studies of scissoring. In the present study, we examined the in vitro endurance of clip twisting to assess clip scissoring. To evaluate the clip-scissoring effect, we measured torque at the rotating aneurysm clip head (Sugita and Yasargil clips) using our own manufactured product. A silicon sheet 1 mm thick was clipped at several depths (3, 6, and 9 mm), and the clip head was mechanically rotated. Straight and fenestrated clips of titanium alloy were used in the present study. Cobalt alloy straight clips were also examined. Preliminary experiments indicated that torque values during clip head rotation dropped when the blades crossed. In addition, torque values before blade crossing showed resistance to slippage of the blades. Torque values of both Sugita and Yasargil clips were directly proportional to the blade depth. There were no differences between straight and fenestrated Sugita clips. Although the torque was greater in cobalt alloy than titanium alloy Sugita clips, the torque values of Yasargil cobalt and titanium clips were identical. We found some differences in torque values during clip head rotation between Sugita and Yasargil clips. Based on the results of twisting experiments, scissoring is likely to occur when occluding the neck of the aneurysm only with the tips of long clip blades. |
資源タイプ(コンテンツの種類) |
|
|
内容記述 |
Article |
ISSN |
|
|
収録物識別子タイプ |
PISSN |
|
収録物識別子 |
0344-5607 |
書誌レコードID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA00324143 |
PubMed |
|
|
|
関連識別子 |
https://pubmed.ncbi.nlm.nih.gov/21912864 |
|
|
関連名称 |
21912864 |
権利 |
|
|
権利情報 |
The original publication is available at www.springerlink.com |
出版タイプ |
|
|
出版タイプ |
AM |
|
出版タイプResource |
http://purl.org/coar/version/c_ab4af688f83e57aa |
WoS |
|
|
URL |
http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000301707000015 |