{"_buckets": {"deposit": "618ecd25-302c-4f7b-aa4d-4cbfaf250eb0"}, "_deposit": {"id": "3887", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "3887"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00003887", "sets": ["461:462"]}, "author_link": ["7775", "7776", "7777", "7778", "7779", "7780", "7781"], "item_1628147817048": {"attribute_name": "\u51fa\u7248\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_6_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-11", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "8", "bibliographicPageEnd": "1150", "bibliographicPageStart": "1143", "bibliographicVolumeNumber": "14", "bibliographic_titles": [{"bibliographic_title": "RESPIROLOGY"}]}]}, "item_6_description_20": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "Background and objective: The SD-101 is a non-restrictive, sheet-like medical device with an array of pressure sensors, to detect sleep-disordered breathing by sensing gravitational alterations in the body corresponding to respiratory movements. This study evaluated the accuracy of the SD-101 for screening sleep apnoea-hypopnoea syndrome (SAHS) by comparison with polysomnography. Methods: Nocturnal polysomnography and SD-101 monitoring were conducted simultaneously and compared in 201 patients with suspected SAHS (suspected SAHS group) and 165 male employees of a transport company (screening group). Results: Polysomnography revealed an AHI of \u003c5, 5 \u003c= AHI \u003c 15, 15 \u003c= AHI \u003c 30, 30 \u003c= AHI \u003c 60 and AHI \u003e= 60 events/h in 39, 35, 38, 68 and 21 subjects in the suspected SAHS group and 103, 34, 12, 12 and four subjects in the screening group, respectively. Central SAHS and obstructive SAHS were subsequently diagnosed in 11 (5.5%) and 135 (67.2%) of subjects in the suspected SAHS group and five (3.0%) and 39 (23.6%) of subjects in the screening group, respectively. Significant correlations were apparent between AHI and the respiratory disturbance index (RDI) measured with the SD-101 in both the suspected SAHS group (r = 0.88) and screening group (r = 0.92). Receiver operating characteristic curve analysis revealed 89.5% sensitivity and 85.8% specificity in identifying SAHS, using an RDI of 14.0 events/h. Conclusions: These findings suggest that the SD-101 is a useful device for screening SAHS.", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7\uff08\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u7a2e\u985e\uff09", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_31": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff1amime\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "\u5f15\u7528", "attribute_value_mlt": [{"subitem_description": "RESPIROLOGY. 14(8):1143-1150 (2009)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "\u4fe1\u5dde\u5927\u5b66\u7814\u7a76\u8005\u7dcf\u89a7\u3078\u306e\u30ea\u30f3\u30af", "attribute_value_mlt": [{"subitem_link_text": "Fujimoto, Keisaku", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.yFfaHFkh.html"}, {"subitem_link_text": "Urushihata, Kazuhisa", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.jakhHVkh.html"}, {"subitem_link_text": "Honda, Takayuki", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.WeDUHFkh.html"}, {"subitem_link_text": "Tsukahara, Teruomi", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.yaLNbakF.html"}, {"subitem_link_text": "Nomiyama, Tetsuo", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.jNACuakh.html"}]}, "item_6_link_67": {"attribute_name": "WoS", "attribute_value_mlt": [{"subitem_link_text": "Web of Science", "subitem_link_url": "http://gateway.isiknowledge.com/gateway/Gateway.cgi?\u0026GWVersion=2\u0026SrcAuth=ShinshuUniv\u0026SrcApp=ShinshuUniv\u0026DestLinkType=FullRecord\u0026DestApp=WOS\u0026KeyUT=000271064100011"}]}, "item_6_publisher_4": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "WILEY-BLACKWELL PUBLISHING, INC"}]}, "item_6_relation_47": {"attribute_name": "PubMed", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "19818056"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://pubmed.ncbi.nlm.nih.gov/19818056", "subitem_relation_type_select": "PMID"}}]}, "item_6_relation_48": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.1111/j.1440-1843.2009.01627.x"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.1111/j.1440-1843.2009.01627.x", "subitem_relation_type_select": "DOI"}}]}, "item_6_select_64": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1323-7799", "subitem_source_identifier_type": "PISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1323-7799", "subitem_source_identifier_type": "PISSN"}]}, "item_6_source_id_40": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11097269", "subitem_source_identifier_type": "NCID"}]}, "item_6_text_69": {"attribute_name": "wosonly authkey", "attribute_value_mlt": [{"subitem_text_value": "polysomnography; portable device; pressure sensor array; screening; sleep apnoea syndrome"}]}, "item_6_text_70": {"attribute_name": "wosonly keywords", "attribute_value_mlt": [{"subitem_text_value": "POSITIVE AIRWAY PRESSURE; BLOOD-PRESSURE; POLYSOMNOGRAPHY; DISEASE; MEN"}]}, "item_6_textarea_68": {"attribute_name": "wosonly abstract", "attribute_value_mlt": [{"subitem_textarea_value": "Background and objective: The SD-101 is a non-restrictive, sheet-like medical device with an array of pressure sensors, to detect sleep-disordered breathing by sensing gravitational alterations in the body corresponding to respiratory movements. This study evaluated the accuracy of the SD-101 for screening sleep apnoea-hypopnoea syndrome (SAHS) by comparison with polysomnography. Methods: Nocturnal polysomnography and SD-101 monitoring were conducted simultaneously and compared in 201 patients with suspected SAHS (suspected SAHS group) and 165 male employees of a transport company (screening group). Results: Polysomnography revealed an AHI of \u003c5, 5 \u003c= AHI \u003c 15, 15 \u003c= AHI \u003c 30, 30 \u003c= AHI \u003c 60 and AHI \u003e= 60 events/h in 39, 35, 38, 68 and 21 subjects in the suspected SAHS group and 103, 34, 12, 12 and four subjects in the screening group, respectively. Central SAHS and obstructive SAHS were subsequently diagnosed in 11 (5.5%) and 135 (67.2%) of subjects in the suspected SAHS group and five (3.0%) and 39 (23.6%) of subjects in the screening group, respectively. Significant correlations were apparent between AHI and the respiratory disturbance index (RDI) measured with the SD-101 in both the suspected SAHS group (r = 0.88) and screening group (r = 0.92). Receiver operating characteristic curve analysis revealed 89.5% sensitivity and 85.8% specificity in identifying SAHS, using an RDI of 14.0 events/h. Conclusions: These findings suggest that the SD-101 is a useful device for screening SAHS."}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Agatsuma,  Toshihiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "7775", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujimoto,  Keisaku", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "7776", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Komatsu,  Yoshimichi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "7777", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Urushihata,  Kazuhisa", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "7778", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Honda,  Takayuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "7779", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsukahara,  Teruomi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "7780", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nomiyama,  Tetsuo", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "7781", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Usefulness_SD-101_non-restrictive_device_developed.pdf", "filesize": [{"value": "445.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 445100.0, "url": {"label": "Usefulness_SD-101_non-restrictive_device_developed.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/3887/files/Usefulness_SD-101_non-restrictive_device_developed.pdf"}, "version_id": "8a3588c5-ec97-438e-809b-e6d6c0ad4591"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "polysomnography", "subitem_subject_scheme": "Other"}, {"subitem_subject": "portable device", "subitem_subject_scheme": "Other"}, {"subitem_subject": "pressure sensor array", "subitem_subject_scheme": "Other"}, {"subitem_subject": "screening", "subitem_subject_scheme": "Other"}, {"subitem_subject": "sleep apnoea syndrome", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "A novel device (SD-101) with high accuracy for screening sleep apnoea-hypopnoea syndrome", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "A novel device (SD-101) with high accuracy for screening sleep apnoea-hypopnoea syndrome", "subitem_title_language": "en"}]}, "item_type_id": "6", "owner": "1", "path": ["461/462"], "permalink_uri": "http://hdl.handle.net/10091/11077", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2011-01-13"}, "publish_date": "2011-01-13", "publish_status": "0", "recid": "3887", "relation": {}, "relation_version_is_last": true, "title": ["A novel device (SD-101) with high accuracy for screening sleep apnoea-hypopnoea syndrome"], "weko_shared_id": -1}
  1. 050 医学部, 大学院医学系研究科
  2. 0501 学術論文

A novel device (SD-101) with high accuracy for screening sleep apnoea-hypopnoea syndrome

http://hdl.handle.net/10091/11077
4e25a328-776c-423a-b0cb-9927985d5694
名前 / ファイル ライセンス アクション
Usefulness_SD-101_non-restrictive_device_developed.pdf Usefulness_SD-101_non-restrictive_device_developed.pdf (445.1 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2011-01-13
タイトル
言語 en
タイトル A novel device (SD-101) with high accuracy for screening sleep apnoea-hypopnoea syndrome
言語
言語 eng
キーワード
主題Scheme Other
主題 polysomnography
キーワード
主題Scheme Other
主題 portable device
キーワード
主題Scheme Other
主題 pressure sensor array
キーワード
主題Scheme Other
主題 screening
キーワード
主題Scheme Other
主題 sleep apnoea syndrome
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
著者 Agatsuma, Toshihiko

× Agatsuma, Toshihiko

WEKO 7775

en Agatsuma, Toshihiko

Search repository
Fujimoto, Keisaku

× Fujimoto, Keisaku

WEKO 7776

en Fujimoto, Keisaku

Search repository
Komatsu, Yoshimichi

× Komatsu, Yoshimichi

WEKO 7777

en Komatsu, Yoshimichi

Search repository
Urushihata, Kazuhisa

× Urushihata, Kazuhisa

WEKO 7778

en Urushihata, Kazuhisa

Search repository
Honda, Takayuki

× Honda, Takayuki

WEKO 7779

en Honda, Takayuki

Search repository
Tsukahara, Teruomi

× Tsukahara, Teruomi

WEKO 7780

en Tsukahara, Teruomi

Search repository
Nomiyama, Tetsuo

× Nomiyama, Tetsuo

WEKO 7781

en Nomiyama, Tetsuo

Search repository
信州大学研究者総覧へのリンク
氏名 Fujimoto, Keisaku
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.yFfaHFkh.html
信州大学研究者総覧へのリンク
氏名 Urushihata, Kazuhisa
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.jakhHVkh.html
信州大学研究者総覧へのリンク
氏名 Honda, Takayuki
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.WeDUHFkh.html
信州大学研究者総覧へのリンク
氏名 Tsukahara, Teruomi
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.yaLNbakF.html
信州大学研究者総覧へのリンク
氏名 Nomiyama, Tetsuo
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.jNACuakh.html
出版者
出版者 WILEY-BLACKWELL PUBLISHING, INC
引用
内容記述タイプ Other
内容記述 RESPIROLOGY. 14(8):1143-1150 (2009)
書誌情報 RESPIROLOGY

巻 14, 号 8, p. 1143-1150, 発行日 2009-11
抄録
内容記述タイプ Abstract
内容記述 Background and objective: The SD-101 is a non-restrictive, sheet-like medical device with an array of pressure sensors, to detect sleep-disordered breathing by sensing gravitational alterations in the body corresponding to respiratory movements. This study evaluated the accuracy of the SD-101 for screening sleep apnoea-hypopnoea syndrome (SAHS) by comparison with polysomnography. Methods: Nocturnal polysomnography and SD-101 monitoring were conducted simultaneously and compared in 201 patients with suspected SAHS (suspected SAHS group) and 165 male employees of a transport company (screening group). Results: Polysomnography revealed an AHI of <5, 5 <= AHI < 15, 15 <= AHI < 30, 30 <= AHI < 60 and AHI >= 60 events/h in 39, 35, 38, 68 and 21 subjects in the suspected SAHS group and 103, 34, 12, 12 and four subjects in the screening group, respectively. Central SAHS and obstructive SAHS were subsequently diagnosed in 11 (5.5%) and 135 (67.2%) of subjects in the suspected SAHS group and five (3.0%) and 39 (23.6%) of subjects in the screening group, respectively. Significant correlations were apparent between AHI and the respiratory disturbance index (RDI) measured with the SD-101 in both the suspected SAHS group (r = 0.88) and screening group (r = 0.92). Receiver operating characteristic curve analysis revealed 89.5% sensitivity and 85.8% specificity in identifying SAHS, using an RDI of 14.0 events/h. Conclusions: These findings suggest that the SD-101 is a useful device for screening SAHS.
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
ISSN
収録物識別子タイプ PISSN
収録物識別子 1323-7799
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA11097269
PubMed
関連識別子
識別子タイプ PMID
関連識別子 https://pubmed.ncbi.nlm.nih.gov/19818056
関連名称
関連名称 19818056
DOI
関連識別子
識別子タイプ DOI
関連識別子 https://doi.org/10.1111/j.1440-1843.2009.01627.x
関連名称
関連名称 10.1111/j.1440-1843.2009.01627.x
出版タイプ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
WoS
表示名 Web of Science
URL http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000271064100011
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 14:15:48.917913
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio