WEKO3
アイテム
NeuRobot (Microscopic-Micromanipulator System) のエチレンオキサイドガスによる滅菌について : 臨床使用に向けて
http://hdl.handle.net/10091/9358
http://hdl.handle.net/10091/93588eb7cec9-53e0-44a4-95eb-77c90df2be0e
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-03-24 | |||||
タイトル | ||||||
タイトル | NeuRobot (Microscopic-Micromanipulator System) のエチレンオキサイドガスによる滅菌について : 臨床使用に向けて | |||||
タイトル | ||||||
タイトル | Ethylene Oxide on NeuRobot (Microscopic-Micromanipulator System) Following Sterilization : Implications for Clinical Use | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題 | micromanipulator, robotics neurosurgery, ethylene oxide sterilization 微細操作装置, ロボット支援脳神経外科手術, エチレンオキサイド滅菌 |
|||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
後藤, 哲哉
× 後藤, 哲哉× 本郷, 一博× 柿澤, 幸成× 小山, 淳一× 新田, 純平× 田中, 雄一郎× 小林, 茂昭× 村瀬, 澄夫× 澤谷, ゆき江 |
|||||
信州大学研究者総覧へのリンク | ||||||
表示名 | 後藤, 哲哉 | |||||
URL | http://soar-rd.shinshu-u.ac.jp/profile/ja.jCAUHVkh.html | |||||
信州大学研究者総覧へのリンク | ||||||
表示名 | 本郷, 一博 | |||||
URL | http://soar-rd.shinshu-u.ac.jp/profile/ja.jecFHCkh.html | |||||
出版者 | ||||||
出版者 | 信州医学会 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 信州医学雑誌 50(6):347-352(2002) | |||||
書誌情報 |
信州医学雑誌 巻 50, 号 6, p. 347-352, 発行日 2002-12 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | NeuRobot, a telecontrolled micromanipulator system having a three-dimensional rigid neuroendoscope and three guiding-manipulators, has been developed for less invasive and telerobotic neurosurgery. For applying NeuRobot to clinical usage,we investigated whether the system is safely and adequately sterilized by ethylene oxide gas (EOG). Two kinds of experiments were performed : to confirm sterilization and to measure residual EOG level were tested.A total of 16 specimens of biological indicator (Bacillus subtilis 10⁶), placed where it would be difficult for EOG to reach, were completely extincted in half the time of standard EOG sterilization.This indicates that NeuRobot achieved Sterility Assurance Level 10⁻⁶ within the standard EOG sterilization period.At day 14 after standard EOG sterilization, the residual level of EOG on NeuRobot was below 15 ppm. Our results proved that NeuRobot is able to be sterilized by EOG safely and adequately. The system will become a new neurosurgical tool for treating lesions that are difficult to deal with conventional microsurgery or neuroendoscopic surgery. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 0037-3826 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00120815 | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |