{"_buckets": {"deposit": "2d73dceb-5c0a-45d6-a037-be810301fd20"}, "_deposit": {"id": "11841", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "11841"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00011841", "sets": ["1170"]}, "author_link": ["36271", "36272", "36273", "36274"], "item_1628147817048": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_6_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-06-17", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "827", "bibliographicPageStart": "825", "bibliographicVolumeNumber": "25", "bibliographic_titles": [{"bibliographic_title": "ANALYTICAL SCIENCES"}]}]}, "item_6_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "An amperometric biosensor for the detection of glucosamine (GlcN) and chitosan oligosaccharides ((GlcN)(n)) was introduced for an activity measurement of chitosanase. By using the biosensor, an increase in the anodic current due to the production of GlcN and (GlcN)(n) by chitosanase was measured in a chitosan solution. The maximum value of the slope of the current increase was proportional to the enzyme concentration up to 1.4 mu g mL(-1). The present method had the advantages of being simple and rapid over the conventional Elson-Morgan method.", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "ANALYTICAL SCIENCES. 25(6):825-827 (2009)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "信州大学研究者総覧へのリンク", "attribute_value_mlt": [{"subitem_link_text": "Tatsumi, Hirosuke", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.uCkFjFkV.html"}]}, "item_6_link_67": {"attribute_name": "WoS", "attribute_value_mlt": [{"subitem_link_text": "Web of Science", "subitem_link_url": "http://gateway.isiknowledge.com/gateway/Gateway.cgi?\u0026GWVersion=2\u0026SrcAuth=ShinshuUniv\u0026SrcApp=ShinshuUniv\u0026DestLinkType=FullRecord\u0026DestApp=WOS\u0026KeyUT=000266944300015"}]}, "item_6_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "JAPAN SOC ANALYTICAL CHEMISTRY"}]}, "item_6_relation_48": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "10.2116/analsci.25.825"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://doi.org/10.2116/analsci.25.825", "subitem_relation_type_select": "DOI"}}]}, "item_6_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0910-6340", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0910-6340", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA10500785", "subitem_source_identifier_type": "NCID"}]}, "item_6_text_70": {"attribute_name": "wosonly keywords", "attribute_value_mlt": [{"subitem_text_value": "GLUCOSAMINE"}]}, "item_6_textarea_68": {"attribute_name": "wosonly abstract", "attribute_value_mlt": [{"subitem_textarea_value": "An amperometric biosensor for the detection of glucosamine (GlcN) and chitosan oligosaccharides ((GlcN)(n)) was introduced for an activity measurement of chitosanase. By using the biosensor, an increase in the anodic current due to the production of GlcN and (GlcN)(n) by chitosanase was measured in a chitosan solution. The maximum value of the slope of the current increase was proportional to the enzyme concentration up to 1.4 mu g mL(-1). The present method had the advantages of being simple and rapid over the conventional Elson-Morgan method."}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tatsumi, Hirosuke"}], "nameIdentifiers": [{"nameIdentifier": "36271", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Katano, Hajime"}], "nameIdentifiers": [{"nameIdentifier": "36272", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ikeda, Tokuji"}], "nameIdentifiers": [{"nameIdentifier": "36273", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kimoto, Hisashi"}], "nameIdentifiers": [{"nameIdentifier": "36274", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Activity_Measurement_Chitosanase_Amperometric_Biosensor.pdf", "filesize": [{"value": "619.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 619700.0, "url": {"label": "Activity_Measurement_Chitosanase_Amperometric_Biosensor.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/11841/files/Activity_Measurement_Chitosanase_Amperometric_Biosensor.pdf"}, "version_id": "d272053d-8634-4e30-b201-45769652187c"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Activity Measurement of Chitosanase by an Amperometric Biosensor", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Activity Measurement of Chitosanase by an Amperometric Biosensor", "subitem_title_language": "en"}]}, "item_type_id": "6", "owner": "1", "path": ["1170"], "permalink_uri": "http://hdl.handle.net/10091/15947", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2012-09-03"}, "publish_date": "2012-09-03", "publish_status": "0", "recid": "11841", "relation": {}, "relation_version_is_last": true, "title": ["Activity Measurement of Chitosanase by an Amperometric Biosensor"], "weko_shared_id": -1}
Activity Measurement of Chitosanase by an Amperometric Biosensor
http://hdl.handle.net/10091/15947
http://hdl.handle.net/10091/15947c5eb27d5-0af0-4a09-b3be-cba9dfea39fe
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-09-03 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Activity Measurement of Chitosanase by an Amperometric Biosensor | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
Tatsumi, Hirosuke
× Tatsumi, Hirosuke× Katano, Hajime× Ikeda, Tokuji× Kimoto, Hisashi |
|||||
信州大学研究者総覧へのリンク | ||||||
氏名 | Tatsumi, Hirosuke | |||||
URL | http://soar-rd.shinshu-u.ac.jp/profile/ja.uCkFjFkV.html | |||||
出版者 | ||||||
出版者 | JAPAN SOC ANALYTICAL CHEMISTRY | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | ANALYTICAL SCIENCES. 25(6):825-827 (2009) | |||||
書誌情報 |
ANALYTICAL SCIENCES 巻 25, 号 6, p. 825-827, 発行日 2009-06-17 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | An amperometric biosensor for the detection of glucosamine (GlcN) and chitosan oligosaccharides ((GlcN)(n)) was introduced for an activity measurement of chitosanase. By using the biosensor, an increase in the anodic current due to the production of GlcN and (GlcN)(n) by chitosanase was measured in a chitosan solution. The maximum value of the slope of the current increase was proportional to the enzyme concentration up to 1.4 mu g mL(-1). The present method had the advantages of being simple and rapid over the conventional Elson-Morgan method. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0910-6340 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10500785 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.2116/analsci.25.825 | |||||
関連名称 | 10.2116/analsci.25.825 | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
WoS | ||||||
表示名 | Web of Science | |||||
URL | http://gateway.isiknowledge.com/gateway/Gateway.cgi?&GWVersion=2&SrcAuth=ShinshuUniv&SrcApp=ShinshuUniv&DestLinkType=FullRecord&DestApp=WOS&KeyUT=000266944300015 |