アイテム

{"_buckets": {"deposit": "0d901eb3-6f11-4911-9140-ab713f42eaa3"}, "_deposit": {"id": "13109", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "13109"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00013109", "sets": []}, "author_link": ["39967"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1963-12-28", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "10", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "16", "bibliographic_titles": [{"bibliographic_title": "信州大学工学部紀要"}]}]}, "item_10_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In the results that a follow-up accuracy of several mechanical microcomparator having a magnifying device which is constructed with the lever and the gear was investigated by using the C. Zeiss U. M. M. as a standard, their special character which has been hitherto neglected has been clarified. And the chief results which have been obtained by this investigation are as follows: (1) The special character of follow-up accuracy of this mechanical microcomparator is not irregular as it was hitherto considered to be, and it can be explained theoretically enough by the error which is caused by the back lash and the magnifying ratio. (2) The accuracy test of this mechanical micro-comparator has to be done by the above mentioned method instead of those using the block gauge as a standard. (3) This mechanical micro-comparator can be found to be used as a high accuracy one if the special character of follow-up accuracy of it is utilized as a means of correction.", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "フォーマット:mimeタイプ", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "信州大学工学部紀要 16: 1-10 (1963)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "信州大学工学部"}]}, "item_10_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3818", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3818", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00121228", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "01"}]}, "item_1627890569677": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "市川,  誠", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "39967", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Engineering16-01.pdf", "filesize": [{"value": "671.5 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 671500.0, "url": {"label": "Engineering16-01.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/13109/files/Engineering16-01.pdf"}, "version_id": "7e38fa9b-6533-4797-a232-81d9bd281652"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "二,三の機械的測微器の追従精度特性", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "二,三の機械的測微器の追従精度特性", "subitem_title_language": "ja"}, {"subitem_title": "Special Character of Follow-Up Accuracy on Several Mechanical Micro-Comparator", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["1291"], "permalink_uri": "http://hdl.handle.net/10091/11736", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2011-02-15"}, "publish_date": "2011-02-15", "publish_status": "0", "recid": "13109", "relation": {}, "relation_version_is_last": true, "title": ["二,三の機械的測微器の追従精度特性"], "weko_shared_id": -1}
  1. 060 工学部
  2. 0602 紀要
  3. 06021 信州大学工学部紀要
  4. Vol. 16

二,三の機械的測微器の追従精度特性

http://hdl.handle.net/10091/11736
http://hdl.handle.net/10091/11736
4d13f745-e83b-49aa-896f-eb807e48cbed
名前 / ファイル ライセンス アクション
Engineering16-01.pdf Engineering16-01.pdf (671.5 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2011-02-15
タイトル
言語 ja
タイトル 二,三の機械的測微器の追従精度特性
タイトル
言語 en
タイトル Special Character of Follow-Up Accuracy on Several Mechanical Micro-Comparator
言語
言語 jpn
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
著者 市川, 誠

× 市川, 誠

WEKO 39967

ja 市川, 誠

Search repository
出版者
出版者 信州大学工学部
引用
内容記述タイプ Other
内容記述 信州大学工学部紀要 16: 1-10 (1963)
書誌情報 信州大学工学部紀要

巻 16, p. 1-10, 発行日 1963-12-28
抄録
内容記述タイプ Abstract
内容記述 In the results that a follow-up accuracy of several mechanical microcomparator having a magnifying device which is constructed with the lever and the gear was investigated by using the C. Zeiss U. M. M. as a standard, their special character which has been hitherto neglected has been clarified. And the chief results which have been obtained by this investigation are as follows: (1) The special character of follow-up accuracy of this mechanical microcomparator is not irregular as it was hitherto considered to be, and it can be explained theoretically enough by the error which is caused by the back lash and the magnifying ratio. (2) The accuracy test of this mechanical micro-comparator has to be done by the above mentioned method instead of those using the block gauge as a standard. (3) This mechanical micro-comparator can be found to be used as a high accuracy one if the special character of follow-up accuracy of it is utilized as a means of correction.
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
ISSN
収録物識別子タイプ ISSN
収録物識別子 0037-3818
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00121228
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 11:10:38.732577
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3