WEKO3
アイテム
{"_buckets": {"deposit": "0d901eb3-6f11-4911-9140-ab713f42eaa3"}, "_deposit": {"id": "13109", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "13109"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00013109", "sets": []}, "author_link": ["39967"], "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1963-12-28", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "10", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "16", "bibliographic_titles": [{"bibliographic_title": "信州大学工学部紀要"}]}]}, "item_10_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In the results that a follow-up accuracy of several mechanical microcomparator having a magnifying device which is constructed with the lever and the gear was investigated by using the C. Zeiss U. M. M. as a standard, their special character which has been hitherto neglected has been clarified. And the chief results which have been obtained by this investigation are as follows: (1) The special character of follow-up accuracy of this mechanical microcomparator is not irregular as it was hitherto considered to be, and it can be explained theoretically enough by the error which is caused by the back lash and the magnifying ratio. (2) The accuracy test of this mechanical micro-comparator has to be done by the above mentioned method instead of those using the block gauge as a standard. (3) This mechanical micro-comparator can be found to be used as a high accuracy one if the special character of follow-up accuracy of it is utilized as a means of correction.", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "フォーマット:mimeタイプ", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "信州大学工学部紀要 16: 1-10 (1963)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "信州大学工学部"}]}, "item_10_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3818", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3818", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00121228", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "01"}]}, "item_1627890569677": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "市川, 誠", "creatorNameLang": "ja"}], "nameIdentifiers": [{"nameIdentifier": "39967", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Engineering16-01.pdf", "filesize": [{"value": "671.5 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 671500.0, "url": {"label": "Engineering16-01.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/13109/files/Engineering16-01.pdf"}, "version_id": "7e38fa9b-6533-4797-a232-81d9bd281652"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "二,三の機械的測微器の追従精度特性", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "二,三の機械的測微器の追従精度特性", "subitem_title_language": "ja"}, {"subitem_title": "Special Character of Follow-Up Accuracy on Several Mechanical Micro-Comparator", "subitem_title_language": "en"}]}, "item_type_id": "10", "owner": "1", "path": ["1291"], "permalink_uri": "http://hdl.handle.net/10091/11736", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2011-02-15"}, "publish_date": "2011-02-15", "publish_status": "0", "recid": "13109", "relation": {}, "relation_version_is_last": true, "title": ["二,三の機械的測微器の追従精度特性"], "weko_shared_id": -1}
二,三の機械的測微器の追従精度特性
http://hdl.handle.net/10091/11736
http://hdl.handle.net/10091/117364d13f745-e83b-49aa-896f-eb807e48cbed
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-02-15 | |||||
タイトル | ||||||
言語 | ja | |||||
タイトル | 二,三の機械的測微器の追従精度特性 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Special Character of Follow-Up Accuracy on Several Mechanical Micro-Comparator | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
著者 |
市川, 誠
× 市川, 誠 |
|||||
出版者 | ||||||
出版者 | 信州大学工学部 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 信州大学工学部紀要 16: 1-10 (1963) | |||||
書誌情報 |
信州大学工学部紀要 巻 16, p. 1-10, 発行日 1963-12-28 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In the results that a follow-up accuracy of several mechanical microcomparator having a magnifying device which is constructed with the lever and the gear was investigated by using the C. Zeiss U. M. M. as a standard, their special character which has been hitherto neglected has been clarified. And the chief results which have been obtained by this investigation are as follows: (1) The special character of follow-up accuracy of this mechanical microcomparator is not irregular as it was hitherto considered to be, and it can be explained theoretically enough by the error which is caused by the back lash and the magnifying ratio. (2) The accuracy test of this mechanical micro-comparator has to be done by the above mentioned method instead of those using the block gauge as a standard. (3) This mechanical micro-comparator can be found to be used as a high accuracy one if the special character of follow-up accuracy of it is utilized as a means of correction. | |||||