ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "5fe85b7a-0c08-44b3-b019-edff1daa1511"}, "_deposit": {"id": "13471", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "13471"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00013471", "sets": ["1310"]}, "author_link": ["41101", "41102", "41103"], "item_1628147817048": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_6_alternative_title_1": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Individual Modeling Method Based on the X-Ray CT Images (Influence of Partial Volume Effect on the Modeling)"}]}, "item_6_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2003-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "677", "bibliographicPageEnd": "114", "bibliographicPageStart": "109", "bibliographicVolumeNumber": "69", "bibliographic_titles": [{"bibliographic_title": "日本機械学会論文集. A編"}]}]}, "item_6_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Reliable stress analysis of a bone requires not only precision in shape of the finite element model but also proper setting of material constants for the model. This paper deals with estimation of Young\u0027s modulus to the finite elements based on the X-ray CT data. At first, partial volume effect on the modeling was discussed by analytical and experimental ways using acrylic cylindrical specimen. Second, a simple correction method which transforms the CT value around border of the object was proposed. In this correction method, CT value larger than the threshold value was pulled up to the target CT value. To confirm validity of the proposed correction method, a load test and stress analyses using a dry mandible were performed. Analytical displacement between condyles and maximum principal strains were well coincided with these of experiments.", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_31": {"attribute_name": "フォーマット:mimeタイプ", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "日本機械学会論文集. A編. 69(677):109-114 (2003)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "信州大学研究者総覧へのリンク", "attribute_value_mlt": [{"subitem_link_text": "小関, 道彦", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.ZenFupLV.html"}]}, "item_6_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "社団法人日本機械学会"}]}, "item_6_relation_51": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110002370280/", "subitem_relation_type_select": "URI"}}]}, "item_6_rights_62": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright (c) 2003 社団法人 日本機械学会"}, {"subitem_rights": "本文データは学協会の許諾に基づきCiNiiから複製したものである"}]}, "item_6_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0387-5008", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0387-5008", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN0018742X", "subitem_source_identifier_type": "NCID"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "伊能,  教夫"}], "nameIdentifiers": [{"nameIdentifier": "41101", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小関,  道彦"}], "nameIdentifiers": [{"nameIdentifier": "41102", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "槇,  宏太郎"}], "nameIdentifiers": [{"nameIdentifier": "41103", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "110002370280.pdf", "filesize": [{"value": "818.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_note", "mimetype": "application/pdf", "size": 818700.0, "url": {"label": "110002370280.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/13471/files/110002370280.pdf"}, "version_id": "82f4fadb-983a-4fd7-b958-8a530cff026e"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Biomechanics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Computational Mechanics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Finite Element Method", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Individual Modeling", "subitem_subject_scheme": "Other"}, {"subitem_subject": "X-Ray CT", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Partial Volume Effect", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Human Mandible", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "X線CT画像に基づく骨体の個体別モデリング手法に関する研究(部分体積効果のモデリングへの影響)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "X線CT画像に基づく骨体の個体別モデリング手法に関する研究(部分体積効果のモデリングへの影響)", "subitem_title_language": "ja"}]}, "item_type_id": "6", "owner": "1", "path": ["1310"], "permalink_uri": "http://hdl.handle.net/10091/3818", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2010-01-20"}, "publish_date": "2010-01-20", "publish_status": "0", "recid": "13471", "relation": {}, "relation_version_is_last": true, "title": ["X線CT画像に基づく骨体の個体別モデリング手法に関する研究(部分体積効果のモデリングへの影響)"], "weko_shared_id": -1}
  1. 080 繊維学部
  2. 0801 学術論文

X線CT画像に基づく骨体の個体別モデリング手法に関する研究(部分体積効果のモデリングへの影響)

http://hdl.handle.net/10091/3818
http://hdl.handle.net/10091/3818
ddfa6c9d-c908-46ee-963b-c01478d8e5da
名前 / ファイル ライセンス アクション
110002370280.pdf 110002370280.pdf (818.7 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2010-01-20
タイトル
言語 ja
タイトル X線CT画像に基づく骨体の個体別モデリング手法に関する研究(部分体積効果のモデリングへの影響)
言語
言語 jpn
キーワード
主題Scheme Other
主題 Biomechanics
キーワード
主題Scheme Other
主題 Computational Mechanics
キーワード
主題Scheme Other
主題 Finite Element Method
キーワード
主題Scheme Other
主題 Individual Modeling
キーワード
主題Scheme Other
主題 X-Ray CT
キーワード
主題Scheme Other
主題 Partial Volume Effect
キーワード
主題Scheme Other
主題 Human Mandible
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
その他(別言語等)のタイトル
その他のタイトル Individual Modeling Method Based on the X-Ray CT Images (Influence of Partial Volume Effect on the Modeling)
著者 伊能, 教夫

× 伊能, 教夫

WEKO 41101

伊能, 教夫

Search repository
小関, 道彦

× 小関, 道彦

WEKO 41102

小関, 道彦

Search repository
槇, 宏太郎

× 槇, 宏太郎

WEKO 41103

槇, 宏太郎

Search repository
信州大学研究者総覧へのリンク
氏名 小関, 道彦
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.ZenFupLV.html
出版者
出版者 社団法人日本機械学会
引用
内容記述タイプ Other
内容記述 日本機械学会論文集. A編. 69(677):109-114 (2003)
書誌情報 日本機械学会論文集. A編

巻 69, 号 677, p. 109-114, 発行日 2003-01
抄録
内容記述タイプ Abstract
内容記述 Reliable stress analysis of a bone requires not only precision in shape of the finite element model but also proper setting of material constants for the model. This paper deals with estimation of Young's modulus to the finite elements based on the X-ray CT data. At first, partial volume effect on the modeling was discussed by analytical and experimental ways using acrylic cylindrical specimen. Second, a simple correction method which transforms the CT value around border of the object was proposed. In this correction method, CT value larger than the threshold value was pulled up to the target CT value. To confirm validity of the proposed correction method, a load test and stress analyses using a dry mandible were performed. Analytical displacement between condyles and maximum principal strains were well coincided with these of experiments.
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
ISSN
収録物識別子タイプ ISSN
収録物識別子 0387-5008
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN0018742X
異版である
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 http://ci.nii.ac.jp/naid/110002370280/
権利
権利情報 Copyright (c) 2003 社団法人 日本機械学会
権利
権利情報 本文データは学協会の許諾に基づきCiNiiから複製したものである
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 11:01:46.077770
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3