{"_buckets": {"deposit": "d4bbc9c2-2b31-468e-a2fc-60032787aefc"}, "_deposit": {"id": "16961", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "16961"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00016961"}, "item_11_alternative_title_1": {"attribute_name": "\u305d\u306e\u4ed6\uff08\u5225\u8a00\u8a9e\u7b49\uff09\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "A Preliminary Study of Regulating Mechanisums on Liver Tissues Blood Flow"}]}, "item_11_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1990-03-31", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "113", "bibliographicPageStart": "110", "bibliographicVolumeNumber": "12", "bibliographic_titles": [{"bibliographic_title": "\u74b0\u5883\u79d1\u5b66\u5e74\u5831"}]}]}, "item_11_description_20": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "The comparison between liver tissue blood flow and skin blood flow was made by a laser-Doppler velocimetry in rabbits. The liver tissue and skin blood flows seemed to by inversely correlated to each other. When the environmental temperature was lawered from 30.C to 20.C\uff0cth e skin blood flow decreased to 45% of the previous control value\uff0cbu t the liver tissue blood flow remained unchanged. Furtuer\uff0cw hen the both ear lobe tips were warmed up by water of 42.C\uff0cth e skin blood flow increased three times as many as that of the control\uff0cbut the liver tissue blood flow was reduced to 55% of the control. When 10% blood of the circulating volume was exsanguinated at as low pace\uff0cb oth the skin blood flow and the femoral blood pressure were obviously lowered\uff0cw hereas the liver tissue blood flow was almost maintained or even increased slight1y. It would therefore be suggested that there could be some regulating mechanisms as for the liver tissue blood flo", "subitem_description_type": "Abstract"}]}, "item_11_description_30": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7\uff08\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u7a2e\u985e\uff09", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_11_description_31": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff1amime\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_11_description_5": {"attribute_name": "\u5f15\u7528", "attribute_value_mlt": [{"subitem_description": "\u74b0\u5883\u79d1\u5b66\u5e74\u583112:110-113(1990)", "subitem_description_type": "Other"}]}, "item_11_publisher_4": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u4fe1\u5dde\u5927\u5b66\u74b0\u5883\u79d1\u5b66\u7814\u7a76\u4f1a"}]}, "item_11_select_64": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_11_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0915-7492", "subitem_source_identifier_type": "ISSN"}]}, "item_11_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0915-7492", "subitem_source_identifier_type": "ISSN"}]}, "item_11_source_id_40": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN1054947X", "subitem_source_identifier_type": "NCID"}]}, "item_11_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "15"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u77f3\u66fd\u6839,  \u65b0\u516b"}], "nameIdentifiers": [{"nameIdentifier": "48505", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u7af9\u5ca1,  \u307f\u3061\u5b50"}], "nameIdentifiers": [{"nameIdentifier": "48506", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u9152\u4e95,  \u79cb\u7537"}], "nameIdentifiers": [{"nameIdentifier": "48507", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u4e0a\u7530,  \u4e94\u96e8"}], "nameIdentifiers": [{"nameIdentifier": "48508", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u5e55\u5185,  \u96c5\u654f"}], "nameIdentifiers": [{"nameIdentifier": "48509", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-28"}], "displaytype": "detail", "download_preview_message": "", "filename": "12-16.pdf", "filesize": [{"value": "237.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2376000, "url": {"label": "12-16.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/16961/files/12-16.pdf"}, "version_id": "dfe288c0-66ed-4ad7-aebf-869666899e37"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "laser-Doppler velocimetry", "subitem_subject_scheme": "Other"}, {"subitem_subject": "liver tissue blood flow", "subitem_subject_scheme": "Other"}, {"subitem_subject": "skin blood flow.", "subitem_subject_scheme": "Other"}, {"subitem_subject": "\u30ec\u30fc\u30b6\u30fc\u30c9\u30c3\u30d7\u30e9\u4e00\u6cd5", "subitem_subject_scheme": "Other"}, {"subitem_subject": "\u809d\u7d44\u7e54\u8840\u6d41", "subitem_subject_scheme": "Other"}, {"subitem_subject": "\u76ae\u819a\u8840\u6d41", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "research report", "resourceuri": "http://purl.org/coar/resource_type/c_18ws"}]}, "item_title": "\u809d\u306e\u8840\u6d41\u8abf\u7bc0\u6a5f\u5e8f\u306b\u95a2\u3059\u308b\u4e88\u5099\u7684\u7814\u7a76", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u809d\u306e\u8840\u6d41\u8abf\u7bc0\u6a5f\u5e8f\u306b\u95a2\u3059\u308b\u4e88\u5099\u7684\u7814\u7a76"}]}, "item_type_id": "11", "owner": "1", "path": ["1628/1629/1657"], "permalink_uri": "http://hdl.handle.net/10091/12514", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_name_i18n": "\u516c\u958b\u65e5", "attribute_value": "2011-04-19"}, "publish_date": "2011-04-19", "publish_status": "0", "recid": "16961", "relation": {}, "relation_version_is_last": true, "title": ["\u809d\u306e\u8840\u6d41\u8abf\u7bc0\u6a5f\u5e8f\u306b\u95a2\u3059\u308b\u4e88\u5099\u7684\u7814\u7a76"], "weko_shared_id": null}
  1. 900 信州大学刊行物
  2. 信州大学 環境科学年報
  3. Vol. 12

肝の血流調節機序に関する予備的研究

http://hdl.handle.net/10091/12514
8b7ba7b9-c4c7-407e-b583-3b8551f46cf3
プレビュー
名前 / ファイル ライセンス Actions
12-16.pdf 12-16.pdf (237.6 kB)
item type 研究報告書 / Research Paper(1)
公開日 2011-04-19
タイトル
タイトル 肝の血流調節機序に関する予備的研究
言語
言語 jpn
キーワード
主題 laser-Doppler velocimetry
キーワード
主題 liver tissue blood flow
キーワード
主題 skin blood flow.
キーワード
主題 レーザードップラ一法
キーワード
主題 肝組織血流
キーワード
主題 皮膚血流
資源タイプ
資源 http://purl.org/coar/resource_type/c_18ws
タイプ research report
その他(別言語等)のタイトル
その他のタイトル A Preliminary Study of Regulating Mechanisums on Liver Tissues Blood Flow
著者 石曽根, 新八

× 石曽根, 新八

WEKO 48505

石曽根, 新八

Search repository
竹岡, みち子

× 竹岡, みち子

WEKO 48506

竹岡, みち子

Search repository
酒井, 秋男

× 酒井, 秋男

WEKO 48507

酒井, 秋男

Search repository
上田, 五雨

× 上田, 五雨

WEKO 48508

上田, 五雨

Search repository
幕内, 雅敏

× 幕内, 雅敏

WEKO 48509

幕内, 雅敏

Search repository
出版者
出版者 信州大学環境科学研究会
引用
内容記述タイプ Other
内容記述 環境科学年報12:110-113(1990)
書誌情報 環境科学年報

巻 12, p. 110-113, 発行日 1990-03-31
抄録
内容記述タイプ Abstract
内容記述 The comparison between liver tissue blood flow and skin blood flow was made by a laser-Doppler velocimetry in rabbits. The liver tissue and skin blood flows seemed to by inversely correlated to each other. When the environmental temperature was lawered from 30.C to 20.C,th e skin blood flow decreased to 45% of the previous control value,bu t the liver tissue blood flow remained unchanged. Furtuer,w hen the both ear lobe tips were warmed up by water of 42.C,th e skin blood flow increased three times as many as that of the control,but the liver tissue blood flow was reduced to 55% of the control. When 10% blood of the circulating volume was exsanguinated at as low pace,b oth the skin blood flow and the femoral blood pressure were obviously lowered,w hereas the liver tissue blood flow was almost maintained or even increased slight1y. It would therefore be suggested that there could be some regulating mechanisms as for the liver tissue blood flo
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
ISSN
収録物識別子タイプ ISSN
収録物識別子 0915-7492
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN1054947X
著者版フラグ
値 publisher
Back
0
views
See details
Views

Versions

Ver.1 2021-03-01 09:47:03.526021
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio