ログイン
言語:

WEKO3

  • トップ
  • コミュニティ
  • ランキング
AND
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "bd4ae908-93c6-4c2f-945f-8bb684d4993d"}, "_deposit": {"id": "4342", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "4342"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00004342"}, "item_6_alternative_title_1": {"attribute_name": "\u305d\u306e\u4ed6\uff08\u5225\u8a00\u8a9e\u7b49\uff09\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "New Methods of Cerebral Angiography Using Rotational Digital Subtraction Angiography and Multi-Slice Three-Dimensional Computed Tomography Angiography with Intra-Arterial Injection"}]}, "item_6_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2001-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "89", "bibliographicPageStart": "85", "bibliographicVolumeNumber": "49", "bibliographic_titles": [{"bibliographic_title": "\u4fe1\u5dde\u533b\u5b66\u96d1\u8a8c"}]}]}, "item_6_description_20": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "We describe our early experience with rotational digital subtraction angiography and multi-slice threedimensional computed tomography angiography with intra-arterial injection.Thirty-five patients admitted to the Department of Neurosurgery,Shinshu University Hospital,underwent examination with these techniques from June 2000. The three-dimensional images are helpful for more accurate diagnosis, and for simulating surgical procedures. Representative cases with cerebral aneurysm, arteriovenous malformation, brain tumor and ischemic disease are presented.", "subitem_description_type": "Abstract"}]}, "item_6_description_30": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7\uff08\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u7a2e\u985e\uff09", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_6_description_31": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff1amime\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_6_description_5": {"attribute_name": "\u5f15\u7528", "attribute_value_mlt": [{"subitem_description": "\u4fe1\u5dde\u533b\u5b66\u96d1\u8a8c 49(2): 85-89(2001)", "subitem_description_type": "Other"}]}, "item_6_link_3": {"attribute_name": "\u4fe1\u5dde\u5927\u5b66\u7814\u7a76\u8005\u7dcf\u89a7\u3078\u306e\u30ea\u30f3\u30af", "attribute_value_mlt": [{"subitem_link_text": "\u4f0a\u6771, \u6e05\u5fd7", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.HFfVuakh.html"}, {"subitem_link_text": "\u672c\u90f7, \u4e00\u535a", "subitem_link_url": "http://soar-rd.shinshu-u.ac.jp/profile/ja.jecFHCkh.html"}]}, "item_6_publisher_4": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u4fe1\u5dde\u533b\u5b66\u4f1a"}]}, "item_6_select_64": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_6_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3826", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0037-3826", "subitem_source_identifier_type": "ISSN"}]}, "item_6_source_id_40": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00120815", "subitem_source_identifier_type": "NCID"}]}, "item_6_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "04"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u67ff\u6fa4,  \u5e78\u6210"}], "nameIdentifiers": [{"nameIdentifier": "10167", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u9577\u5cf6,  \u4e45"}], "nameIdentifiers": [{"nameIdentifier": "10168", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u5927\u5c4b,  \u623f\u4e00"}], "nameIdentifiers": [{"nameIdentifier": "10169", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u4f0a\u6771,  \u6e05\u5fd7"}], "nameIdentifiers": [{"nameIdentifier": "10170", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u672c\u90f7,  \u4e00\u535a"}], "nameIdentifiers": [{"nameIdentifier": "10171", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u5c0f\u6797,  \u8302\u662d"}], "nameIdentifiers": [{"nameIdentifier": "10172", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u9e7f\u9593,  \u76f4\u4eba"}], "nameIdentifiers": [{"nameIdentifier": "10173", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u6df1\u4f5c,  \u548c\u660e"}], "nameIdentifiers": [{"nameIdentifier": "10174", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u89d2\u8c37,  \u771e\u6f84"}], "nameIdentifiers": [{"nameIdentifier": "10175", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u9ad8\u672c,  \u4fe1\u6cbb"}], "nameIdentifiers": [{"nameIdentifier": "10176", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u6728\u85e4,  \u5584\u6d69"}], "nameIdentifiers": [{"nameIdentifier": "10177", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-24"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Shinshu_Med49-2-04.pdf", "filesize": [{"value": "357.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 357000.0, "url": {"label": "Shinshu_Med49-2-04.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/4342/files/Shinshu_Med49-2-04.pdf"}, "version_id": "f81bc677-659d-453b-9b2a-926b1c8f8ebb"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "rotational 3-dimensional DSA", "subitem_subject_scheme": "Other"}, {"subitem_subject": "3-dimensional computed tomography", "subitem_subject_scheme": "Other"}, {"subitem_subject": "multi-slice CT", "subitem_subject_scheme": "Other"}, {"subitem_subject": "\u56de\u8ee23D-DSA", "subitem_subject_scheme": "Other"}, {"subitem_subject": "3D-CT", "subitem_subject_scheme": "Other"}, {"subitem_subject": "\u30de\u30eb\u30c1\u30b9\u30e9\u30a4\u30b9CT", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u56de\u8ee2DSA\u3068\u7d4c\u52d5\u8108\u76843D-CT angiography\u3092\u7528\u3044\u305f\u65b0\u3057\u3044\u8133\u8840\u7ba1\u64ae\u5f71\u6cd5", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u56de\u8ee2DSA\u3068\u7d4c\u52d5\u8108\u76843D-CT angiography\u3092\u7528\u3044\u305f\u65b0\u3057\u3044\u8133\u8840\u7ba1\u64ae\u5f71\u6cd5"}]}, "item_type_id": "6", "owner": "1", "path": ["461/463/464/549"], "permalink_uri": "http://hdl.handle.net/10091/9293", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2010-03-24"}, "publish_date": "2010-03-24", "publish_status": "0", "recid": "4342", "relation": {}, "relation_version_is_last": true, "title": ["\u56de\u8ee2DSA\u3068\u7d4c\u52d5\u8108\u76843D-CT angiography\u3092\u7528\u3044\u305f\u65b0\u3057\u3044\u8133\u8840\u7ba1\u64ae\u5f71\u6cd5"], "weko_shared_id": null}
  1. 050 医学部, 大学院医学系研究科
  2. 0502 紀要・刊行物
  3. 05021 信州医学雑誌
  4. Vol. 49 No. 2

回転DSAと経動脈的3D-CT angiographyを用いた新しい脳血管撮影法

http://hdl.handle.net/10091/9293
a20e63f9-def3-448a-8563-a596d4747b41
名前 / ファイル ライセンス アクション
Shinshu_Med49-2-04.pdf Shinshu_Med49-2-04.pdf (357.0 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2010-03-24
タイトル
タイトル 回転DSAと経動脈的3D-CT angiographyを用いた新しい脳血管撮影法
言語
言語 jpn
キーワード
主題Scheme Other
主題 rotational 3-dimensional DSA
キーワード
主題Scheme Other
主題 3-dimensional computed tomography
キーワード
主題Scheme Other
主題 multi-slice CT
キーワード
主題Scheme Other
主題 回転3D-DSA
キーワード
主題Scheme Other
主題 3D-CT
キーワード
主題Scheme Other
主題 マルチスライスCT
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
その他(別言語等)のタイトル
その他のタイトル New Methods of Cerebral Angiography Using Rotational Digital Subtraction Angiography and Multi-Slice Three-Dimensional Computed Tomography Angiography with Intra-Arterial Injection
著者 柿澤, 幸成

× 柿澤, 幸成

WEKO 10167

柿澤, 幸成

Search repository
長島, 久

× 長島, 久

WEKO 10168

長島, 久

Search repository
大屋, 房一

× 大屋, 房一

WEKO 10169

大屋, 房一

Search repository
伊東, 清志

× 伊東, 清志

WEKO 10170

伊東, 清志

Search repository
本郷, 一博

× 本郷, 一博

WEKO 10171

本郷, 一博

Search repository
小林, 茂昭

× 小林, 茂昭

WEKO 10172

小林, 茂昭

Search repository
鹿間, 直人

× 鹿間, 直人

WEKO 10173

鹿間, 直人

Search repository
深作, 和明

× 深作, 和明

WEKO 10174

深作, 和明

Search repository
角谷, 眞澄

× 角谷, 眞澄

WEKO 10175

角谷, 眞澄

Search repository
高本, 信治

× 高本, 信治

WEKO 10176

高本, 信治

Search repository
木藤, 善浩

× 木藤, 善浩

WEKO 10177

木藤, 善浩

Search repository
信州大学研究者総覧へのリンク
氏名 伊東, 清志
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.HFfVuakh.html
信州大学研究者総覧へのリンク
氏名 本郷, 一博
URL http://soar-rd.shinshu-u.ac.jp/profile/ja.jecFHCkh.html
出版者
出版者 信州医学会
引用
内容記述タイプ Other
内容記述 信州医学雑誌 49(2): 85-89(2001)
書誌情報 信州医学雑誌

巻 49, 号 2, p. 85-89, 発行日 2001-04
抄録
内容記述タイプ Abstract
内容記述 We describe our early experience with rotational digital subtraction angiography and multi-slice threedimensional computed tomography angiography with intra-arterial injection.Thirty-five patients admitted to the Department of Neurosurgery,Shinshu University Hospital,underwent examination with these techniques from June 2000. The three-dimensional images are helpful for more accurate diagnosis, and for simulating surgical procedures. Representative cases with cerebral aneurysm, arteriovenous malformation, brain tumor and ischemic disease are presented.
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
ISSN
収録物識別子タイプ ISSN
収録物識別子 0037-3826
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00120815
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 14:07:03.714171
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio