WEKO3
AND
アイテム
{"_buckets": {"deposit": "00794ba4-ced8-46e6-b32f-ffff16726778"}, "_deposit": {"id": "6941", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "6941"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00006941"}, "item_10_alternative_title_1": {"attribute_name": "\u305d\u306e\u4ed6\uff08\u5225\u8a00\u8a9e\u7b49\uff09\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "Clinical Evaluation of Semiconductor Biosensor"}]}, "item_10_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1993-02-28", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "29", "bibliographicPageStart": "19", "bibliographicVolumeNumber": "18", "bibliographic_titles": [{"bibliographic_title": "\u7d00\u8981"}]}]}, "item_10_description_20": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "The incidence of diabetes mellitus is increasing every year,recently. A blood sugar value is one of the most important items in blood tests, and it varies with meals or exercises. Therefore it is necessary to establish a simple and accurate method for measuring glucose concentration. A glucose sensor is newly invented by applying SOS (Silicone On Sapphire)/ISFET (Ion Sensitive Field Effect Transistor). In this paper, its efficiency in measuring glucose concentration in blood plasma is investigated.", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7\uff08\u30b3\u30f3\u30c6\u30f3\u30c4\u306e\u7a2e\u985e\uff09", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff1amime\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "\u5f15\u7528", "attribute_value_mlt": [{"subitem_description": "\u7d00\u8981 18: 19-29(1993)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u4fe1\u5dde\u5927\u5b66\u533b\u7642\u6280\u8853\u77ed\u671f\u5927\u5b66\u90e8"}]}, "item_10_select_64": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385-1982", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385-1982", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_40": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN10402438", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "03"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u517c\u5409, \u662d\u96c4"}], "nameIdentifiers": [{"nameIdentifier": "16845", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u7be0\u539f, \u5fd7\u7dd2"}], "nameIdentifiers": [{"nameIdentifier": "16846", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u5409\u7530, \u5b89\u96c4"}], "nameIdentifiers": [{"nameIdentifier": "16847", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u5927\u5009, \u535a\u6587"}], "nameIdentifiers": [{"nameIdentifier": "16848", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Allied_Med18_03.pdf", "filesize": [{"value": "871.5 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 871500.0, "url": {"label": "Allied_Med18_03.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/6941/files/Allied_Med18_03.pdf"}, "version_id": "3dbd34dd-b5a9-4054-bb2f-2d8f37c47c57"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "\u30d0\u30a4\u30aa\u30bb\u30f3\u30b5", "subitem_subject_scheme": "Other"}, {"subitem_subject": "\u534a\u5c0e\u4f53", "subitem_subject_scheme": "Other"}, {"subitem_subject": "SOS/\u30a4\u30aa\u30f3\u611f\u5fdc\u6027\u96fb\u754c\u52b9\u679c\u30c8\u30e9\u30f3\u30b8\u30b9\u30bf", "subitem_subject_scheme": "Other"}, {"subitem_subject": "\u8840\u7cd6\u5024", "subitem_subject_scheme": "Other"}, {"subitem_subject": "\u30b0\u30eb\u30b3\u30fc\u30b9", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Biosensor", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Semiconductor", "subitem_subject_scheme": "Other"}, {"subitem_subject": "SOS/ISFET", "subitem_subject_scheme": "Other"}, {"subitem_subject": "blood sugar", "subitem_subject_scheme": "Other"}, {"subitem_subject": "glucose", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u534a\u5c0e\u4f53\u30b0\u30eb\u30b3\u30fc\u30b9\u30bb\u30f3\u30b5\u306e\u81e8\u5e8a\u7684\u8a55\u4fa1", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u534a\u5c0e\u4f53\u30b0\u30eb\u30b3\u30fc\u30b9\u30bb\u30f3\u30b5\u306e\u81e8\u5e8a\u7684\u8a55\u4fa1"}]}, "item_type_id": "10", "owner": "1", "path": ["461/463/805/815"], "permalink_uri": "http://hdl.handle.net/10091/5165", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2010-03-01"}, "publish_date": "2010-03-01", "publish_status": "0", "recid": "6941", "relation": {}, "relation_version_is_last": true, "title": ["\u534a\u5c0e\u4f53\u30b0\u30eb\u30b3\u30fc\u30b9\u30bb\u30f3\u30b5\u306e\u81e8\u5e8a\u7684\u8a55\u4fa1"], "weko_shared_id": null}
半導体グルコースセンサの臨床的評価
http://hdl.handle.net/10091/5165
2396a9df-007d-4acb-9892-4c9be946171d
名前 / ファイル | ライセンス | アクション | |
---|---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2010-03-01 | |||||
タイトル | ||||||
タイトル | 半導体グルコースセンサの臨床的評価 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | バイオセンサ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 半導体 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | SOS/イオン感応性電界効果トランジスタ | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 血糖値 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | グルコース | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Biosensor | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Semiconductor | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | SOS/ISFET | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | blood sugar | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | glucose | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
その他(別言語等)のタイトル | ||||||
その他のタイトル | Clinical Evaluation of Semiconductor Biosensor | |||||
著者 |
兼吉, 昭雄
× 兼吉, 昭雄× 篠原, 志緒× 吉田, 安雄× 大倉, 博文 |
|||||
出版者 | ||||||
出版者 | 信州大学医療技術短期大学部 | |||||
引用 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 紀要 18: 19-29(1993) | |||||
書誌情報 |
紀要 巻 18, p. 19-29, 発行日 1993-02-28 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The incidence of diabetes mellitus is increasing every year,recently. A blood sugar value is one of the most important items in blood tests, and it varies with meals or exercises. Therefore it is necessary to establish a simple and accurate method for measuring glucose concentration. A glucose sensor is newly invented by applying SOS (Silicone On Sapphire)/ISFET (Ion Sensitive Field Effect Transistor). In this paper, its efficiency in measuring glucose concentration in blood plasma is investigated. | |||||
資源タイプ(コンテンツの種類) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Article | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0385-1982 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN10402438 |