ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "9b601958-ec5c-49b8-838d-bb751eb2723e"}, "_deposit": {"id": "6989", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "6989"}, "status": "published"}, "_oai": {"id": "oai:soar-ir.repo.nii.ac.jp:00006989", "sets": ["823"]}, "item_10_alternative_title_1": {"attribute_name": "その他(別言語等)のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "A comparison of temperature and humidity in the interstice of cock-up splint with different shock absorbers"}]}, "item_10_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1988-03-26", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "63", "bibliographicPageStart": "59", "bibliographicVolumeNumber": "13", "bibliographic_titles": [{"bibliographic_title": "紀要"}]}]}, "item_10_description_20": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Thermoplastics are being commonly used for hand splinting in combination with different shock absorbers. In order to assess the effect of  splinting on temperature and humidity in the interstice (the space between the shock absorber and the skin), 1 gyps and 6 thermoplastic cock-up splints with a shock absorber for each, were fitted into 10 normal subjects. The thermal and humidity censor was set at two different points in the interstice : the frontal center of the forearm and the center of the palm. the successive change of temperature and humidity per minute was recorded by the micro memorycorder for 3 hours. In relation to the change, of temperature there was not a significant difference among shock absorbers in both points. However, the humidity was the highest in the PE-right (2.8mm) and lowered in the order of the cotton (0.2mm), no shock absorber, the Ortex, the leather (1. 6mm), the gyps, and the felt (3. 0mm). The humidity of the palm was 10-20% higher than the forearm. The results suggest that the shock absorver for hand splinting should be aerate and hydrophilic in quality the texture to decrease the physical uncomfortableness from perspiration.", "subitem_description_type": "Abstract"}]}, "item_10_description_30": {"attribute_name": "資源タイプ(コンテンツの種類)", "attribute_value_mlt": [{"subitem_description": "Article", "subitem_description_type": "Other"}]}, "item_10_description_31": {"attribute_name": "フォーマット:mimeタイプ", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_10_description_5": {"attribute_name": "引用", "attribute_value_mlt": [{"subitem_description": "紀要 13(2): 59-63(1988)", "subitem_description_type": "Other"}]}, "item_10_publisher_4": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "信州大学医療技術短期大学部"}]}, "item_10_select_64": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_10_source_id_35": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385-1982", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_39": {"attribute_name": "NII ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385-1982", "subitem_source_identifier_type": "ISSN"}]}, "item_10_source_id_40": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00354907", "subitem_source_identifier_type": "NCID"}]}, "item_10_text_66": {"attribute_name": "sortkey", "attribute_value_mlt": [{"subitem_text_value": "05"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "清水,  順市"}], "nameIdentifiers": [{"nameIdentifier": "16973", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤,  真一"}], "nameIdentifiers": [{"nameIdentifier": "16974", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2015-09-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "Allied_Med13_2_05.pdf", "filesize": [{"value": "256.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 256600.00000000003, "url": {"label": "Allied_Med13_2_05.pdf", "url": "https://soar-ir.repo.nii.ac.jp/record/6989/files/Allied_Med13_2_05.pdf"}, "version_id": "8d93c8b5-ac3e-4e52-81b6-266e988dab4e"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "cock-up split", "subitem_subject_scheme": "Other"}, {"subitem_subject": "interstice temperature and humidity", "subitem_subject_scheme": "Other"}, {"subitem_subject": "shock absorbers for splinting", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "装具装着時の装具内における温度・湿度の継時的変化 : 装具,温度,湿度", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "装具装着時の装具内における温度・湿度の継時的変化 : 装具,温度,湿度"}]}, "item_type_id": "10", "owner": "1", "path": ["823"], "permalink_uri": "http://hdl.handle.net/10091/5126", "pubdate": {"attribute_name": "公開日", "attribute_value": "2010-03-01"}, "publish_date": "2010-03-01", "publish_status": "0", "recid": "6989", "relation": {}, "relation_version_is_last": true, "title": ["装具装着時の装具内における温度・湿度の継時的変化 : 装具,温度,湿度"], "weko_shared_id": null}
  1. 050 医学部, 大学院医学系研究科
  2. 0502 紀要・刊行物
  3. 05022 医療技術短期大学部紀要
  4. Vol. 13 No.2

装具装着時の装具内における温度・湿度の継時的変化 : 装具,温度,湿度

http://hdl.handle.net/10091/5126
http://hdl.handle.net/10091/5126
e3cef578-13fd-43a1-832c-40c015347472
名前 / ファイル ライセンス アクション
Allied_Med13_2_05.pdf Allied_Med13_2_05.pdf (256.6 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2010-03-01
タイトル
タイトル 装具装着時の装具内における温度・湿度の継時的変化 : 装具,温度,湿度
言語
言語 jpn
キーワード
主題Scheme Other
主題 cock-up split
キーワード
主題Scheme Other
主題 interstice temperature and humidity
キーワード
主題Scheme Other
主題 shock absorbers for splinting
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
その他(別言語等)のタイトル
その他のタイトル A comparison of temperature and humidity in the interstice of cock-up splint with different shock absorbers
著者 清水, 順市

× 清水, 順市

WEKO 16973

清水, 順市

Search repository
佐藤, 真一

× 佐藤, 真一

WEKO 16974

佐藤, 真一

Search repository
出版者
出版者 信州大学医療技術短期大学部
引用
内容記述タイプ Other
内容記述 紀要 13(2): 59-63(1988)
書誌情報 紀要

巻 13, 号 2, p. 59-63, 発行日 1988-03-26
抄録
内容記述タイプ Abstract
内容記述 Thermoplastics are being commonly used for hand splinting in combination with different shock absorbers. In order to assess the effect of splinting on temperature and humidity in the interstice (the space between the shock absorber and the skin), 1 gyps and 6 thermoplastic cock-up splints with a shock absorber for each, were fitted into 10 normal subjects. The thermal and humidity censor was set at two different points in the interstice : the frontal center of the forearm and the center of the palm. the successive change of temperature and humidity per minute was recorded by the micro memorycorder for 3 hours. In relation to the change, of temperature there was not a significant difference among shock absorbers in both points. However, the humidity was the highest in the PE-right (2.8mm) and lowered in the order of the cotton (0.2mm), no shock absorber, the Ortex, the leather (1. 6mm), the gyps, and the felt (3. 0mm). The humidity of the palm was 10-20% higher than the forearm. The results suggest that the shock absorver for hand splinting should be aerate and hydrophilic in quality the texture to decrease the physical uncomfortableness from perspiration.
資源タイプ(コンテンツの種類)
内容記述タイプ Other
内容記述 Article
ISSN
収録物識別子タイプ ISSN
収録物識別子 0385-1982
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00354907
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 13:09:01.641637
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3